Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems
The DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Abstract
In order to increase the reliability and availability of wind turbines, condition monitoring and fault diagnosis are considered crucial means to achieve these goals. In this context, direct drives wind turbines based on permanent-magnet synchronous generators (PMSGs) with full-scale power converters are an emerging and promising technology. However, several statistical studies point out that power converters are a significant contributor to the overall failure rate of modern wind turbines. Accordingly, this paper presents a new algorithm for multiple open-circuit faults diagnosis in full-scale back-to-back converters, applied in PMSG drives used for wind turbine systems. The proposed method is based on a Luenberger observer and on an adaptive threshold, which can guarantee a reliable diagnosis independently of the drive operating conditions. Several simulation and experimental results using a PMSG drive with a full-scale converter are presented, showing the diagnostic algorithm effectiveness and robustness against false alarms for both generator- and grid-side converters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This observation provides sufficient information to detect faulty transistors in power converters [269], [270].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [269]
Citations
Cites
Luenberger, D. (1971) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1971.1099826 · Cited by 2,709 · cited 1×
“The Luenberger state observer [38] has been widely used for the control of PMSM drives [39], [40] and for three phase”
MethodAn Industry-Based Survey of Reliability in Power Electronic Converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124436 · Cited by 2,019
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860 · cited 1×
“A comparative study between different powers switches technologies used in wind energy conversion systems, and types of faults that can occur in these semiconductors is also presented in [5].”
BackgroundAgeing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Fault detection of open-switch damage in voltage-fed PWM motor drive systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.809351 · Cited by 441 · cited 1×
“Fast detection times can be achieved using voltage-based techniques at the cost of additional voltage sensors [9]–[11].”
BackgroundFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J.-P. (1998) · IEEE Transactions on Industry Applications · doi:10.1109/28.739017 · Cited by 384
Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361 · cited 1×
“A diagnostic method based on sliding mode observer for open-circuit faults in modular multilevel converters was proposed in [25].”
MethodFault detection and isolation on a PWM inverter by knowledge-based model
Peuget, R., Courtine, S., & Rognon, J. P. (2002) · IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting · doi:10.1109/ias.1997.629048 · Cited by 304 · cited 1×
“The current space vector trajectory diameter can also be used for the localization of inverter power switch open-circuit faults [7], [8].”
Background
Research works printed but not linked: 1
- 10.1109/iemdc.1999.769220 · DOI · Paper page
Cited by
Items 201–216 of 216
Improved Response of the Wind Energy System underIslanded Microgrid
Sharma, R., & Kumar, S. (2020) · IEEE International Conference on Measurement, Instrumentation, Control and Automation (ICMICA) · doi:10.1109/icmica48462.2020.9242767
“The generator side fully controlled rectifier based control techniques are suggested by [6]-[7] to reduce the torque ripples and improve the armature current waveform, but this technique is increased the overall cost of the system and the control complexity.”
Fault Diagnosis and Fault-Tolerant SVPWM Technique of Six-phase Converter under Open-Switch Fault
Bolbolnia, R., & Abbaszadeh, K. (2022) · Journal of Iranian Association of Electrical and Electronics Engineers · doi:10.52547/jiaeee.19.4.93
A robust multiple open-switch fault diagnosis approach for converter in wind energy system
Liang, J., Tian, Z., & Zhou, D. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99666-2.15002-6
Intelligent fault diagnosis scheme for converter in wind turbine systems
Liang, J., Wei, Z., Wang, J., Lei, Y., & Zhou, D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13613-9.00014-3
Introduction to Fault‐Tolerant Machine Drives
Wang, B., & Wang, J. (2024) · Wiley eBooks · doi:10.1002/9781394252046.ch1
Laadjal, K., Amaral, A. M. R., Serra, J., & Cardoso, A. J. M. (2024) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce55643.2024.10861468
Moros, D. (2025) · Wind Energy Science Discussions · doi:10.5194/wes-2025-84-ac2
Vu, H.-G., & Nguyen, D. T. (2025) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v16.i4.pp2178-2185
Research on Fault Diagnosis of Converters and Sensors in Doubly-Fed Wind Power Generation Systems
Lyu, S. (2025) · Industry science and engineering. · doi:10.62381/i255807
Advanced Fault Detection in Cascaded H-Bridge Multilevel Inverters with LS-PWM Control
Roy, R., & Kumar, C. (2025) · IEEE Uttar Pradesh Section International Conference on Electrical, Electronics and Computer Engineering (UPCON) · doi:10.1109/upcon66414.2025.11453977
Optimized Control Strategies for Low Voltage Grid-connected Modular Multilevel Converters (MMCs)
Abdayem, A. (2024) · theses.fr (ABES) · doi:10.70675/bc305e3fzc61ez4933z93a7z37ccd9cd4c26
Wei, Q., Xu, X., Gao, X., & Wang, K. (2026) · International Conference on Green Energy and Power Systems (ICGEPS) · doi:10.1109/icgeps69938.2026.11522160
“Jlassi et al. proposed a state observer method capable of diagnosing multiple open-circuit faults [4] .”
Qiao, L., & Li, W. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae7fa6
“Methods such as support vector machines (SVM) [3], adaptive fuzzy inference systems [4], decision trees [5], extreme learning machines (ELM) [6], and XGBoost [7] have been widely adopted.”
Jayasena, K. N. C., Batkhishig, B., Nahid‐Mobarakeh, B., & Emadi, A. (2026) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2026.3716568
“Several methods are reported in the literature, including disturbance observer-based approaches [25], Luenberger observers [26], [27], [28], sliding mode observers [29], [30], and model predictive control (MPC) [31], [32].”
Khansary, A., Poshtan, J., Khansary, V., & Khansary, E. (2026) · doi:10.1109/icee70628.2026.11710670
“In [4],[5], a Sliding Mode Observer (SMO) is employed for open-switch fault diagnosis in induction motor drives.”
Metadata
- Authors
- Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J.
- Affiliations
- University of Beira Interior (PT)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2015-05
- Volume
- 30
- Issue
- 5
- Pages
- 2689-2702
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2067610416
- Cited by
- 212
- References
- 43
- Citations by year
- 2026: 5 · 2025: 11 · 2024: 15 · 2023: 21 · 2022: 18 · 2021: 17 · 2020: 21 · 2019: 28 · 2018: 20 · 2017: 20 · 2016: 24 · 2015: 12
- FWCI
- 9.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- Portuguese Foundation for Science and Technology (SFRH/BPD/87135/2012)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- open-circuit fault diagnosis, back-to-back converter, permanent magnet synchronous generator, direct-drive wind turbine, Luenberger observer, adaptive threshold, condition monitoring, generator-side converter, grid-side converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.