Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
This paper analyzes the small-signal impedance of three-phase grid-tied inverters with feedback control and phase-locked loop (PLL) in the synchronous reference (d-q) frame. The result unveils an interesting and important feature of three-phase grid-tied inverters - namely, that its q-q channel impedance behaves as a negative incremental resistor. Moreover, this paper shows that this behavior is a consequence of grid synchronization, where the bandwidth of the PLL determines the frequency range of the resistor behavior, and the power rating of the inverter determines the magnitude of the resistor. Advanced PLL, current, and power control strategies do not change this feature. An example shows that under weak grid conditions, a change of the PLL bandwidth could lead the inverter system to unstable conditions as a result of this behavior. Harmonic resonance and instability issues can be analyzed using the proposed impedance model. Simulation and experimental measurements verify the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjaer, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,588
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Self-citationPower-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Cited by
Grid-Forming Converters: Control Approaches, Grid-Synchronization, and Future Trends—A Review
Rosso, R., Wang, X., Liserre, M., Lu, X., & Engelken, S. (2021) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2021.3074028 · Cited by 1,187
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory
Li, Y., Gu, Y., & Green, T. C. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3151851 · Cited by 686
Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
Harnefors, L., Wang, X., Yepes, A. G., & Blaabjerg, F. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2490549 · Cited by 674
Subsynchronous Interaction Between Direct-Drive PMSG Based Wind Farms and Weak AC Networks
Liu, H., Xie, X., He, J., Xu, T., Yu, Z., Wang, C., & Zhang, C. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2682197 · Cited by 623
Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586
Self-citationZhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters
Wu, H., & Wang, X. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2937942 · Cited by 454
Wang, L., Qin, Z., Slangen, T., Bauer, P., & van Wijk, T. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3054601 · Cited by 417
Wu, W., Liu, Y., He, Y., Chung, H. S.-H., Liserre, M., & Blaabjerg, F. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2714143 · Cited by 397
Lyu, J., Zhang, X., Cai, X., & Molinas, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2842682 · Cited by 345
Huang, L., Xin, H., Wang, Z., Wu, K., Wang, H., Hu, J., & Lu, C. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2740424 · Cited by 342
Couplings in Phase Domain Impedance Modelling of Grid-Connected Converters
Bakhshizadeh, M. K., Wang, X., Blaabjerg, F., Hjerrild, J., Kocewiak, L., Bak, C. L., & Hesselbek, B. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2542244 · Cited by 302
Placing Grid-Forming Converters to Enhance Small Signal Stability of PLL-Integrated Power Systems
Yang, C., Huang, L., Xin, H., & Ju, P. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3042741 · Cited by 279
Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
“The d–q impedances of two-level grid-connected inverters with feedback control and PLL were derived and measured in [20]–[22], and an impedance-based stability analysis for three-phase gridconnected paralleled converters was performed in [22].”
MethodZhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2811718 · Cited by 262
Huang, L., Xin, H., Li, Z., Ju, P., Yuan, H., Lan, Z., & Wang, Z. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2924295 · Cited by 252
“The analysis in [9] has shown that GSI would be potentially caused by the negative resistance of the power converter’s q-q channel impedance, which falls into the category of small-signal stability.”
BackgroundInfluentialCatalán, P., Wang, Y., Arza, J., & Chen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3234221 · Cited by 197
“The influence of PLL bandwidth on stability is investigated in [146], where the high gain could cause instability of the system under weak grid conditions.”
BackgroundLyu, J., Cai, X., & Molinas, M. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2759096 · Cited by 194
“Since the wind turbine is based on two-level VSCs and the impedance modeling of two-level VSCs has been well studied [26], [27], the detailed impedance derivations of the wind farm will be no longer presented in this paper.”
BackgroundRobust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Robust Stability Analysis of LCL Filter Based Synchronverter Under Different Grid Conditions
Rosso, R., Cassoli, J., Buticchi, G., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2867040 · Cited by 89
“Recent studies have shown that synchronization units of grid-connected converters, usually phase-locked loops (PLLs), affect significantly the stability of the converters within their bandwidths [1].”
BackgroundGrid-Forming and Spatially Distributed Control Design of Dynamic Virtual Power Plants
Häberle, V., Tayyebi, A., He, X., Prieto-Araujo, E., & Dörfler, F. (2024) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2023.3311481 · Cited by 58
“Namely, while the frequency deviation obtained by the classical p - f control of the DVPP (Fig.”
BackgroundRavanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
“Reducing the PLL bandwidth [7], employing enhanced PLLs [8], using virtual impedances [9], and proposing novel grid-following control schemes [10], [11]”
MethodGuruwacharya, N., Chakraborty, S., Saraswat, G., Bryce, R., Hansen, T. M., & Tonkoski, R. (2024) · IEEE Access · doi:10.1109/access.2024.3383323 · Cited by 34
“However, the PLL can cause instability issues in the grid, especially when the grid impedance is high [16], [17].”
Background
Metadata
- Authors
- Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2016-01
- Volume
- 31
- Issue
- 1
- Pages
- 675-687
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W1974967408
- Cited by
- 1,334
- References
- 25
- FWCI
- 61.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.