High-Efficiency Bidirectional Buck–Boost Converter for Photovoltaic and Energy Storage Systems in a Smart Grid
The DOI matches its Crossref record; 29 of the 31 references it cites were found in a registry or an index.
Abstract
This paper proposes a new bidirectional buck-boost converter, which is a key component in a photovoltaic and energy storage system (ESS). Conventional bidirectional buck-boost converters for ESSs operate in discontinuous conduction mode (DCM) to achieve zero-voltage switching turn-ON for switches. However, operation in DCM causes high ripples in the output voltage and current, as well as low power-conversion efficiency. To improve the performance of the conventional converter, the proposed converter has a new combined structure of a cascaded buck-boost converter and an auxiliary capacitor. The combined structure of the proposed converter reduces the output current ripple by providing a current path and the efficiency is increased. A prototype was built and tested to verify the effectiveness of the converter. The proposed converter has a maximum efficiency of 98%, less than 5.14 Vp.pof output voltage ripple, and less than 7.12 Ap.pof output current ripple. These results were obtained at an input voltage of 160 V, switching frequency of 45 kHz, output voltage of 80-320 V, and output power of 16-160 W. The experimental results show that the proposed converter has improved performance compared to the conventional converter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“First, the increased number of components leads to a larger overall size and higher manufacturing costs [42].”
From Bidirectional DC-DC Converter Topologies for Hybrid Energy Storage Systems in Electric Vehicles: A Comprehensive Review (2025) · cites this paper as [42]
In the citing paper
“Coupled inductor technology was initially introduced in unidirectional ´ Cuk converters to reduce input and output current ripple, which enhances circuit performance and efficiency [42].”
From Bidirectional DC-DC Converter Topologies for Hybrid Energy Storage Systems in Electric Vehicles: A Comprehensive Review (2025) · cites this paper as [42]
In the citing paper
“More specifically, the bidirectional Buck-Boost converter operates in the forward mode by stepping the input voltage either up or down to the desired output voltage [42].”
From Bidirectional DC-DC Converter Topologies for Hybrid Energy Storage Systems in Electric Vehicles: A Comprehensive Review (2025) · cites this paper as [42]
Citations
Cites
Energy Storage Systems for Transport and Grid Applications
Vazquez, S., Lukic, S. M., Galvan, E., Franquelo, L. G., & Carrasco, J. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2076414 · Cited by 1,347
A Generic Battery Model for the Dynamic Simulation of Hybrid Electric Vehicles
Tremblay, O., Dessaint, L.-A., & Dekkiche, A.-I. (2007) · 2007 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2007.4544139 · Cited by 1,244 · cited 1×
“Therefore, when the input is a photovoltaic (PV) module and the output is battery cells in a smart grid, a half bridge converter based on a buck or boost converter cannot be used because of the following reasons: 1) The battery cells repeatedly perform charging and discharging operations, resulting in large voltage va…”
BackgroundLiu, X., Aichhorn, A., Liu, L., & Li, H. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2177501 · Cited by 486 · cited 1×
“The proposed converter is targeted to a PV-ESS system that uses a micro-inverter, which has been widely used in a smart grid [29, 30].”
MethodBuilding Integrated Photovoltaic System With Energy Storage and Smart Grid Communication
Sechilariu, M., Wang, B., & Locment, F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222852 · Cited by 332 · cited 1×
“Therefore, an energy storage system (ESS) is needed in a smart grid to provide stability and efficiently manage the renewable energy [1-3].”
BackgroundDesign and Analysis of a Full-Bridge LLC-Based PEV Charger Optimized for Wide Battery Voltage Range
Wang, H., Dusmez, S., & Khaligh, A. (2014) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2013.2288772 · Cited by 293 · cited 1×
“Therefore, when the input is a photovoltaic (PV) module and the output is battery cells in a smart grid, a half bridge converter based on a buck or boost converter cannot be used because of the following reasons: 1) The battery cells repeatedly perform charging and discharging operations, resulting in large voltage va…”
BackgroundA Novel Low-Loss Modulation Strategy for High-Power Bidirectional Buck ${\bm +}$ Boost Converters
Waffler, S., & Kolar, J. W. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2015881 · Cited by 276
Analysis and Implementation of a Novel Bidirectional DC–DC Converter
Yang, L.-S., & Liang, T.-J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2134060 · Cited by 261
A stand-alone photovoltaic supercapacitor battery hybrid energy storage system
Glavin, M. E., Chan, P. K. W., Armstrong, S., & Hurley, W. G. (2008) · 2008 13th International Power Electronics and Motion Control Conference · doi:10.1109/epepemc.2008.4635510 · Cited by 259 · cited 1×
“battery and renewable energy source in both directions [4-9].”
BackgroundPower Electronics, Smart Grid, and Renewable Energy Systems
Bose, B. K. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2745621 · Cited by 242 · cited 1×
“Therefore, an energy storage system (ESS) is needed in a smart grid to provide stability and efficiently manage the renewable energy [1-3].”
BackgroundSwitching Power Supplies A - Z
(2012) · Elsevier eBooks · doi:10.1016/c2010-0-68564-6 · Cited by 215 · cited 1×
“The five main causes of power dissipation in the proposed converter include the switching and conduction losses of switches, the winding and core losses of inductor L, and the equivalent series resistance (ESR) losses of the capacitors [31-33].”
Background
Research works printed but not linked: 4
- ridley, 2016, Magnetics core loss, Lecture Ridley Engineering
- wen, 2014, Analysis of buck converter efficiency, Application Note Richtek Technology
- lim, 2017, Nonisolated two-phase bidirectional DC-DC converter with zero-voltage-transition for battery energy storage system, J Elect Eng Technol, 12, 2237
- du, 0, Review of nonisolated bi-directional DC–DC converters for plug-in hybrid electric vehicle charge station application at municipal parking decks, Proc IEEE Appl Power Electron Conf, 1145
Cited by
Topologies and Control Schemes of Bidirectional DC–DC Power Converters: An Overview
Gorji, S. A., Sahebi, H. G., Ektesabi, M., & Rad, A. B. (2019) · IEEE Access · doi:10.1109/access.2019.2937239 · Cited by 439
“CONVERTER [19], [20]”
BackgroundA Novel SiC-Based Multifunctional Onboard Battery Charger for Plug-In Electric Vehicles
Nguyen, H. V., Lee, D., & Blaabjerg, F. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3026034 · Cited by 115
Alatai, S., Salem, M., Ishak, D., Das, H. S., Nazari, M. A., Bughneda, A., & Jamil, M. K. M. (2021) · Applied Sciences · doi:10.3390/app112110172 · Cited by 131
“In comparison to the combined half-bridge (CHB) converter, the CBB converter is smaller and more efficient at converting power because it only utilizes one inductor [48].”
BackgroundOverview of Technical Specifications for Grid-Connected Microgrid Battery Energy Storage Systems
Khalid, A., Stevenson, A., & Sarwat, A. I. (2021) · IEEE Access · doi:10.1109/access.2021.3132223 · Cited by 115
“A cascaded buck-boost converter implementation with batteries can be found in [87], where a low output ripple current was achieved.”
BackgroundPires, V. F., Cordeiro, A., Foito, D., & Silva, J. F. (2021) · IEEE Access · doi:10.1109/access.2021.3122877 · Cited by 95
Tong, Y., Salhi, I., Wang, Q., Lu, G., & Wu, S. (2025) · Energies · doi:10.3390/en18092312 · Cited by 60
“More specifically, the bidirectional Buck-Boost converter operates in the forward mode by stepping the input voltage either up or down to the desired output voltage [42].”
InfluentialSutikno, T., Aprilianto, R. A., & Purnama, H. S. (2023) · Clean Energy · doi:10.1093/ce/zkac070 · Cited by 66
Pseudo DC-Link EV Home Charger With a High Semiconductor Device Utilization Factor
Heydari‐doostabad, H., Hosseini, S. H., Ghazi, R., & O’Donnell, T. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3065623 · Cited by 57
“To avoid this issue, bidirectional buck–boost (BBB) converters with both step-down and step-up capabilities have been developed to regulate the battery and the dc-link voltages during forward (V2G) and backward (G2V) modes of operation [7], [8].”
BackgroundInfluentialCheng, Z., Li, Z., Li, S., Gao, J., Si, J., Das, H. S., & Dong, W. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.105950 · Cited by 53
Ahmad, H. J., & Hagiwara, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3106240 · Cited by 39
Gholami, Z., Ildarabadi, R., Heydari‐doostabad, H., Monfared, M., & O’Donnell, T. (2023) · IET Power Electronics · doi:10.1049/pel2.12630 · Cited by 40
Venkatesan, M., Narayanamoorthi, R., Kačor, P., & Vrzala, M. (2024) · Results in Engineering · doi:10.1016/j.rineng.2024.103803 · Cited by 38
Bidirectional Conductive Charging of Electric Vehicles for V2V Energy Exchange
Mahure, P., Keshri, R. K., Abhyankar, R., & Buja, G. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9255386 · Cited by 44
“Instead of using separate converters for the charging and discharging modes of the battery, a bidirectional converter is conveniently selected [5].”
BackgroundMethodNon-Isolated Multiport Converter for Renewable Energy Sources: A Comprehensive Review
Narayanaswamy, J., & Mandava, S. (2023) · Energies · doi:10.3390/en16041834 · Cited by 37
Kanagaraj, N., Mollajafari, M., Mohammadiazar, F., Akbari, E., Sheykhi, E., & Chaoui, H. (2022) · Sustainability · doi:10.3390/su142416698 · Cited by 33
Overview of Voltage Balancing Schemes in Bipolar DC Microgrids
Quan, R., Han, Y., Zhou, M., Yan, C., Yang, P., & Wang, C. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3491292 · Cited by 33
“3) Recent advancements in dc/dc converter technology have improved high-frequency operation, integration, and ef-ficiency [15], [16], leading to more reliable power electronic transformers.”
Munusamy, N., & Indragandhi, V. (2024) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2024.100856 · Cited by 43
Yang, X., Qi, Y., Liu, J., Jia, Z., & Wang, D. (2021) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2020.3048732 · Cited by 30
“In order to integrate the equalizer into the charging and discharging system, it is necessary to use bidirectional converters, such as buck/boost converter [29]–[31], bidirectional full-bridge converter [32]–[34], and cascaded buck–boost (CBB) converter [35], [36].”
MethodArunkumar, C. R., & Manthati, U. B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3270292 · Cited by 28
“Nevertheless, one of the most crucial challenges in implementing RES is the intermittent and non-dispatchable characteristics causing power quality concerns in the clean power generated [2], [3].”
BackgroundEmerging maximum power point control algorithms for PV system: review, challenges and future trends
Siddique, M. A. B., Zhao, D., & Rehman, A. U. (2025) · Electrical Engineering · doi:10.1007/s00202-025-03002-0 · Cited by 26
“The power is conveyed to the joined burden in both situations (ON or OFF) of the working switch [28].”
Yu, C.-H., Jang, S.-R., Kim, H.-S., Kim, T.-H., Son, S.-H., Kwon, C.-H., Jang, I., & Cha, H. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3192048 · Cited by 27
“power density, large conversion ratio for high power, and high reliability are significant challenges [1]–[9].”
BackgroundEfficient DC–DC power converters for fuel‐cell electric vehicle: A qualitative assessment
Kumar, S., Jammeh, S., Samb, R., & Singh, A. P. (2024) · IET Power Electronics · doi:10.1049/pel2.12819 · Cited by 25
Tekin, H., Setrekli, G., Murtulu, E., Karşıyaka, H., & Ertekin, D. (2023) · Electronics · doi:10.3390/electronics12204381 · Cited by 25
Geng, X., He, Y., Zeng, C., Wang, G., Liu, S., Yang, H., Lei, J., Zhao, E., Cao, W., & Li, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3134274 · Cited by 22
Tang, W., Wang, H., Zhu, X., Mo, W., Gao, W., & Yue, X. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3170610 · Cited by 22
Raveendhra, D., Poojitha, R., Narasimharaju, B. L., Domyshev, A., Dreglea, A., Dao, M., Pathak, M. K., Liu, F., & Sidorov, D. (2023) · Energies · doi:10.3390/en16176194 · Cited by 23
“Cascaded Figure 5 [9,10] 1 1 D 1 2 4 - Higher voltage gain - Lower current stress Electric vehicle, Smart grid”
BackgroundZhang, Z., Tu, H., She, X., Sadilek, T., Ramabhadran, R., Hu, H., & Earls, W. (2021) · IEEE Industry Applications Magazine · doi:10.1109/mias.2020.3024495 · Cited by 21
“The modified buck-boost converters in [27] and [28] have a smaller current ripple and a smaller number of switches, respectively.”
BackgroundSecuring Networked Microgrids Operation through DNP3 Protocol Implementation
Soliman, A. S., Saad, A., & Mohammed, O. A. (2021) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias48185.2021.9677139 · Cited by 19
“These DER’s are connected to the network through power electronic converters [3-6].”
BackgroundA New Modulation Strategy for Four-switch Buck-boost Converter with Reduced Freewheeling Current
Liu, Q., Qian, Q., Ren, B., Xu, S., Sun, W., & Li, H. (2020) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec39645.2020.9124107 · Cited by 19
“1) is an excellent candidate for photovoltaic [1] and energy storage [2] applications due to the positive polarity and the ability of both voltage step-up and step-down [3].”
BackgroundMeng, Z., Duan, J., & Sun, L. Z. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3247769 · Cited by 17
Biswas, M., Kim, H.-C., & Park, J.-W. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2024.3403961 · Cited by 19
“…bidirectionally between two dc buses, such as renewable energy systems, dc micro-girds, fuel energy systems, hybrid electric vehicles (HEVs), photovoltaic (PV) hybrid power systems, battery chargers for electric vehicle (EV)/HEV, and more electric aircraft (MEA) [1], [2], [3], [4], [5], [6], [7].”
BackgroundMezouari, M., Megrini, M., & Gaga, A. (2025) · Control Engineering Practice · doi:10.1016/j.conengprac.2025.106371 · Cited by 18
Şahin, Y., Tınğ, N. S., & Yeşilyurt, H. (2023) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.3558 · Cited by 17
“The battery cells repeatedly perform charging and discharging operations, resulting in large voltage variations.(4) Ultra-capacitors can meet high power requirements by controlling ultracapacitor voltage within the inverter's upper and lower operation voltage limits, where the only controllable unit is the bidirection…”
BackgroundVariable Multiple Interleaved Bi-Directional DC/DC Converter with Current Ripple Optimization
Duan, J., Wang, S., Xu, Y., Fan, S., Zhao, K., & Sun, L. Z. (2023) · Applied Sciences · doi:10.3390/app13031744 · Cited by 15
Three‐phase interleaved high step‐up bidirectional DC–DCconverter
Wang, F., Wang, Y., Su, B., & Teng, C. (2020) · IET Power Electronics · doi:10.1049/iet-pel.2020.0295 · Cited by 14
Mosalam, H. A., & Badran, E. A. (2026) · Discover Electronics · doi:10.1007/s44291-026-00168-0 · Cited by 15
RETRACTED ARTICLE: Bidirectional DC-DC converter circuits and smart control algorithms: a review
Viswanatha, V., Ramachandra, A. C., & Reddy, R. (2022) · Journal of Electrical Systems and Information Technology · doi:10.1186/s43067-022-00048-z · Cited by 14
“is common for both the bidirectional converters, the current stress over all the components in the converter is decreased so converter can be used in systems where current stress and high voltage boosting capacity output current ripples [20].”
BackgroundRetractedReal‐Time Implementation and Performance Analysis of Supercapacitor for Energy Storage
Rao, T. E., Sundaram, E., Subramanian, U., Tatikonda, K. M., Gantaiahswamy, G., & Chenniappan, S. (2022) · Wiley eBooks · doi:10.1002/9781119893998.ch6 · Cited by 12
Rahman, A. U., Campagna, N., Pellitteri, F., Tommaso, A. O. D., & Miceli, R. (2024) · IEEE Access · doi:10.1109/access.2024.3451008 · Cited by 12
“Multiport and high-efficiency bi-directional power converters are developed for EVs and MG applications in [23] and [24], these studies focus on the design and hardware testing of power converters specifically.”
BackgroundMandal, S., Prabhakaran, P., Arun Dominic, D., & Parameswaran, A. P. (2025) · IEEE Access · doi:10.1109/access.2025.3595442 · Cited by 11
“Renewable energy sources (RES) like solar photovoltaic, wind energy, and fuel cell technology have emerged as promising solutions for sustainable energy [1].”
An impedance source modular DC/DC converter for energy storage system: analysis and design
Bi, K., Liu, Y., Zhu, Y., & Fan, Q. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107261 · Cited by 11
Ma, B., Jiao, J., & Ye, Z. (2024) · Energies · doi:10.3390/en17153645 · Cited by 10
Montenegro-Oviedo, J. A., Ramos‐Paja, C. A., Orozco-Gutiérrez, M. L., Mejía, É. F., & Serna‐Garcés, S. I. (2023) · Mathematics · doi:10.3390/math11040793 · Cited by 12
Optimization of Minimum Negative Current BCM Synchronous Buck Converter
Tang, Y., Zhang, C., Guo, Y., Sun, H., & Jiang, L. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3210535 · Cited by 10
“ture and high efficiency [1], [2], [3].”
Modified proportional integral controller for single ended primary inductance converter
Abramovich, B. N., Ustinov, D. A., & Abdallah, W. J. (2022) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v13.i2.pp1007-1025 · Cited by 9
Bi, K., Xu, C., Ai, J., Li, J., & Fan, Q. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3367903 · Cited by 9
“The four-switch bidirectional dc–dc converter is often employed in low-voltage dc ESS [8].”
MethodA Novel Bidirectional Modified Zeta Converter With Wide Voltage Conversion Ratio
Mandal, S., & Prabhakaran, P. (2025) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2025.3570022 · Cited by 9
“Achieving a broad voltage gain range is critical for optimizing energy transfer between low-voltage input sources and high-voltage dc buses [1], [2], [3].”
Mitra, S. K., & Karanki, S. B. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3225379 · Cited by 9
“Throughout the years of investigation, several BDCs are proposed in the literature, which is broadly classified into two categories, namely, nonisolated [9], [10], [11], [12], [13], [14], [15] and isolated converters [16], [17], [18], [19], [20].”
BackgroundAn interleaved DC charging solar system for electric vehicle
Faudzi, A., Toha, S. F., Hanifah, R. A., Hasbullah, N. F., & Kamisan, N. A. (2021) · International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering · doi:10.11591/ijpeds.v12.i4.pp2414-2422 · Cited by 10
“The ripple can be reduced by an electronic filter and some can be eliminated by using a voltage regulator [26].”
BackgroundManimaran, N., Baskaran, J., Padmanathan, K., & Mahalakshmi, G. (2024) · Journal of Energy Storage · doi:10.1016/j.est.2024.114484 · Cited by 8
Zambrano-Gutierrez, D. F., Cruz‐Duarte, J. M., Castañeda, H., & Avina‐Cervantes, J. G. (2024) · Mathematics · doi:10.3390/math12233709 · Cited by 8
Design Issues of Hybrid Energy Storage Systems of Electric Vehicles According to Driving Profiles
Frivaldský, M., Danko, M., Schoenfelder, T., & Zavřel, M. (2025) · IEEE Open Journal of Vehicular Technology · doi:10.1109/ojvt.2025.3536176 · Cited by 8
“These systems consist of two or more different energy storage systems with different energy storage technologies [19], [20], [21], [22], [23], [24], [25].”
Ma, H., Lei, J., Qin, G., Guo, Z., & Hao, C. (2025) · Energies · doi:10.3390/en18102650 · Cited by 9
A Review of Control Strategies for Four-Switch Buck–Boost Converters
Lin, G., Li, Y., & Zhang, Z. (2025) · World Electric Vehicle Journal · doi:10.3390/wevj16060315 · Cited by 9
Detection and Analysis of Stress Wave in MOSFET Under Gate-Source Overvoltage Failure
Wang, G., He, Y., Geng, X., Tang, L., Liu, S., Li, Q., & Zhang, K. (2023) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2023.3345306 · Cited by 7
“I N RECENT decades, electric vehicles, the aerospace industry, new energy power generation, and other fields all made extensive use of power electronic devices, including MOSFETs and IGBTs [1], [2], [3], [4], [5].”
BackgroundPower Converter Topologies for Heat Pumps Powered by Renewable Energy Sources: A Literature Review
Assaf, J., Menye, J. S., Camara, M. B., Guilbert, D., & Dakyo, B. (2024) · Electronics · doi:10.3390/electronics13193965 · Cited by 8
Design of LC Filter for Boost Converter with the Considerations of Efficiency and Power Density
Li, X., Zhang, X., & Lin, F. (2020) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon43393.2020.9254758 · Cited by 7
“Stage 1: Analysis of Total Power Loss and Volume with Respect to Indutance and Capacitance To evaluate the efficiency of Boost converter, total power loss [13-15] is analyzed.”
MethodPeddeeti, S., Vuddanti, S., & Babu, B. C. (2021) · Electrical Engineering · doi:10.1007/s00202-021-01377-4 · Cited by 7
Vahid, S., Zolfi, P., & EL-Refaie, A. M. (2021) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon48115.2021.9589088 · Cited by 7
“Considering the common trends in these applications, the power range for this TPC should target a range of 1kW-20kWs [18,19].”
BackgroundWu, Y., & Chen, K.-C. (2022) · Processes · doi:10.3390/pr10122711 · Cited by 7
Kumar, N. B., Uma Maheswara Rao, M., Lakshminarayana, P., Rao, C. N. N., & Veeranjaneyulu, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-28943-1 · Cited by 6
“The buck–boost converter allows both step-up and step-down operation, but its discontinuous input current makes it unsuitable for achieving high voltage gain in PV applications 6,7 .”
Meng, Z., Sun, D., Wang, S., & Sun, L. Z. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3429656 · Cited by 6
“In [7] and [8], the topology of dc/dc converter is optimized to improve its performance (such as smaller output harmonics and faster dynamic response speed).”
Short-Time Scale Mode Transition Control of the Four-Switch Buck-Boost Converter
Xu, H., Wang, F. “., & Guo, H. (2021) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes53652.2021.9683910 · Cited by 6
“INTRODUCTION Four-Switch Buck-Boost(FSBB) converters have been widely used in various applications, such as communication systems, photovoltaic power generation, electric vehicles, power supply systems for portable electronic devices [1], energy storage [2], and other fields, depending on its ability to achieve a wide…”
BackgroundDynamic improvement for phase-shift LLC resonant converter based on disturbance observer
Chen, W., Liu, K., Zhao, J., & Jin, C. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.11.115 · Cited by 6
Suraj, S., Manjarekar, N. S., & Barik, S. (2022) · IEEE International Conference on Power Electronics, Drives and Energy Systems · doi:10.1109/pedes56012.2022.10080229 · Cited by 6
Malek, A., & Varjani, A. Y. (2020) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc49159.2020.9088452 · Cited by 6
“1) is ideal and effective for applications requiring moderate voltage gain but is not proper for higher voltage gain owing to hard switching, high stresses of switches, extreme duty ratio, high conduction losses, and consequently low efficiency [4].”
BackgroundHigh frequency and high efficiency DC-DC converter with sensorless adaptive-sizing technique
Cheng, X., Shao, W., Zhang, Y., Zeng, J., & Zhang, Z. (2019) · IEICE Electronics Express · doi:10.1587/elex.16.20190719 · Cited by 6
“However, high switching frequency also increases switching loss and harms efficiency especially light-load efficiency [9, 10, 11, 12].”
BackgroundSolar Photovoltaic Charging of Electric Vehicle and V2G for Indian Electricity Demand Scenario
Suraj, S., Manjarekar, N. S., & Barik, S. (2023) · Lecture notes in electrical engineering · doi:10.1007/978-981-99-6151-1_12 · Cited by 5
Dan, H., Yang, Y., Zhou, S., Xu, J., Liu, Y., & Su, M. (2025) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2025.3542252 · Cited by 5
“However, the realization of ZVS in [18] and [19] relies on auxiliary inductors, auxiliary capacitors, and auxiliary switches, which increases the burden on the hardware circuits.”
Analysis of Non-isolated Bi-directional DC-DC Converter for Battery Charging Application
Chandel, A., & Singh, R. K. (2022) · International Conference on Energy, Power and Environment (ICEPE) · doi:10.1109/icepe55035.2022.9798372 · Cited by 5
Chen, F., Jou, H., Wu, J., Hung, H.-C., & Luo, J. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3386795 · Cited by 5
“In two-mode operation, when the input and output voltages closely approximate each other, the presence of a dead-zone can lead to a deterioration of system stability between pure boost mode and pure buck mode, which induces low frequency large ripples [14], [15], [16], [17].”
BackgroundSaravanan, S., Pandiyan, P., Chinnadurai, T., Tiwari, R., & Prabaharan, N. (2021) · Engergy systems in electrical engineering · doi:10.1007/978-981-16-4388-0_24 · Cited by 5
Althuwaini, Y. E., & Philbin, S. P. (2021) · International Journal of Renewable Energy Research · doi:10.20508/ijrer.v11i4.12525.g8358 · Cited by 5
An Improved Modulation Strategy for a Four-Switch Buck-Boost Converter with Reduced Current Ripple
Díaz, V., Barrado, A., Lázaro, A., & Zumel, P. (2023) · International Conference on Clean Electrical Power · doi:10.1109/iccep57914.2023.10247450 · Cited by 4
“This feature, combined with the bidirectionality of the converter, makes it a very suitable option for battery chargers [4]–[6] and smart grid applications [7].”
BackgroundMadadi, M., Jazaeri, M., & Molla‐Ahmadian, H. (2025) · e-Prime - Advances in Electrical Engineering Electronics and Energy · doi:10.1016/j.prime.2025.101002 · Cited by 4
Yang, Z., & Zhou, Q. (2024) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2024.102934 · Cited by 4
Research on Bi-directional DC / DC Converter for Energy Storage System
Nie, Z., Chen, J., Dai, R., Han, Y., & Peng, Y. J. (2020) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/603/1/012008 · Cited by 5
“References [1-2] describe the application of energy storage batteries in new energy systems, and references [3-5] describe some bidirectional power electronic topologies.”
BackgroundCommutation strategy for reduced output voltage ripple in alternative cascaded boost converter
García‐Vite, P. M., Rebullosa‐Castillo, J. F., García‐Perales, M. A., Reyes‐García, B. L., & García‐Guendulain, C. (2024) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.4040 · Cited by 4
“5 When a low-voltage generator is employed, a high voltage gain is required to feed an isolated load properly or to tie to the mains electricity system.”
Chen, Z., Han, Y., Yun-Feng, W., Lu, Z., Liu, X., & Zhang, C. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3050744 · Cited by 4
Zhang, L., Yuan, Y., Yihe, S., Cheng, Y., Wu, D., & Ren, L. (2021) · Energy Engineering · doi:10.32604/ee.2022.017463 · Cited by 4
A simple method for controlling buck-boost SEPIC H-bridge inverter
Pratomo, L. H., Paudel, S., & Cahyadi, B. K. (2024) · International Journal of Applied Power Engineering (IJAPE) · doi:10.11591/ijape.v13.i3.pp670-678 · Cited by 4
“The use of traditional boost converters usually increases PV voltage [12].”
BackgroundKalaiyarasan, E., & Singaravelu, S. (2024) · International Journal of Electronics and Communication Engineering · doi:10.14445/23488549/ijece-v11i3p106 · Cited by 3
Characteristic Analysis of the Stress Wave of Silicon MOSFET under Gate-Source Overvoltage Failure
Wang, G., He, Y., Geng, X., Tang, L., Liu, S., & Li, Q. (2022) · International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD) · doi:10.1109/icsmd57530.2022.10058330 · Cited by 3
“In recent decades, MOSFETs and IGBTs have become common power electronic devices used in aerospace, electric vehicles, and new energy power generation [1]–[5].”
BackgroundTowards A Secured SCADA Architecture: A DNP3 Test Case
Soliman, A. S., Devine, R., Landi, D. M. C., Rafin, S. M. S. H., Cintuglu, M. H., & Mohammed, O. A. (2023) · IEEE SoutheastCon · doi:10.1109/southeastcon51012.2023.10115208 · Cited by 4
“Unified data models representing the model parameters and messaging between nodes in needed time frames enable the creation of a good communication architecture [20]-[30].”
MethodPower flow analysis in a distributed network for a smart grid system
Jothi, T., Arun, M., & Varadarajan, M. (2024) · Indonesian Journal of Electrical Engineering and Computer Science · doi:10.11591/ijeecs.v33.i1.pp42-52 · Cited by 3
“Due to the switches in this circuit, it may operate in two modes [23].”
BackgroundBarros, J. D., Silva, J. F., & Rocha, L. (2024) · Electronics · doi:10.3390/electronics13224511 · Cited by 3
Adly, G. S., Anis, W. R., Ezzat, S., & Abdullatif, S. O. (2024) · Discover Applied Sciences · doi:10.1007/s42452-024-05997-w · Cited by 2
“In the photovoltaic industry, boost converters are widely used, either to step up the voltage to match the utility grid specifications [9] or compensate for voltage drop due to partial shading [10, 11].”
Optimized Modulation for the Four-Switch Buck–Boost Converter With Reduced Current Ripple
Díaz, V., Barrado, A., Zumel, P., & Lázaro, A. (2026) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2026.3653129 · Cited by 2
“This feature, combined with the bidirectionality of the converter, makes it a very suitable option for battery chargers [6], [7], [8] and smart grid applications [9].”
Mandal, S., Prabhakaran, P., & Rajagopal, M. (2026) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2026.3678099 · Cited by 2
“Renewable energy sources (RES), including solar photovoltaic (PV), wind energy, and fuel cells, have emerged as promising solutions for sustainable power generation [1].”
Grid Connected PV Fed EV Charging Station for College Campus with an Energy Storage System
Sathyajith, V. P., & Ismayil, C. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-4975-3_62 · Cited by 2
Transformerless bidirectional switched-inductor switched-capacitor converter
Sivaraj, G., & Karpagavalli, P. (2023) · International Journal of Electronics · doi:10.1080/00207217.2023.2248661 · Cited by 2
“A bidirectional converter with a cascaded structure and auxiliary capacitor that can work in boost, buck, and buck-boost modes is described in the literature (Lee & Yun, 2018).”
MethodComparison of several modulation strategies for the Four Switch Buck-Boost converter
Díaz, V., Barrado, A., Lázaro, A., & Zumel, P. (2023) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng58103.2023.10227467 · Cited by 2
“It is also commonly used in smart grids due to its bidirectionality [4].”
BackgroundGarcía-Meré, J. R., Rodríguez, J., & Sebastián, J. (2024) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec48139.2024.10509234 · Cited by 2
“Furthermore, this converter is also used when bidirectional power transfer is required, such as smart grids [9], [10].”
MethodPower Flow Optimization of Bipolar DC Distribution Network Considering Voltage Unbalance
Tao, S., Guan, S., Wang, H., Chen, H., Zhu, X., & Xu, Y. (2024) · International Conference on Harmonics and Quality of Power · doi:10.1109/ichqp61174.2024.10768746 · Cited by 2
“The energy storage unit is linked to the DC distribution network via a bidirectional Buck/Boost circuit, and the converter switch is controlled to realize the bidirectional flow of active power [17].”
Hybrid Control of Bidirectional DC-DC Power Source of Electric Vehicles With Dynamical Brake
Hashemzadeh, F., Mohammadi, V., & Sabahi, M. (2025) · IEEE International Conference on Compatibility, Power Electronics and Power Engineering · doi:10.1109/cpe-powereng63314.2025.11027231 · Cited by 2
“To maximize energy utilization, a bidirectional converter is demonstrated in related literature [41], [42], [43], [44], [45].”
DSPACE1103 Controller for PWM Control of Power Electronic Converters
Amalrajan, R., Gunabalan, R., & Tewari, N. (2020) · Lecture notes in electrical engineering · doi:10.1007/978-981-15-7245-6_24 · Cited by 3
SADIQ, D. (2021) · TechRxiv · doi:10.36227/techrxiv.16699942.v1 · Cited by 3
Rajini, V., Vinu Varshath, S., Dinesh‐Kumar, S. P., Narayanan, K., & Jerry Rinaldo, S. (2023) · International Conference on Circuit, Power and Computing Technologies · doi:10.1109/iccpct58313.2023.10244840 · Cited by 1
Research on Soft Switching of Four-Switch Buck-Boost Converter
Liu, Y., & Wang, J. (2024) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc-ecceasia60879.2024.10567834 · Cited by 1
Ren, L., Wang, D., Wang, J., Zhang, S., Li, Y., & Song, K. (2024) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc62350.2024.10587629 · Cited by 1
Metadata
- Authors
- Lee, H.-S., & Yun, J.-J.
- Affiliations
- Pohang University of Science and Technology (KR)
- Daegu University (KR)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2019-05
- Volume
- 34
- Issue
- 5
- Pages
- 4316-4328
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2883184743
- Cited by
- 123
- References
- 31
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 26 · 2023: 21 · 2022: 17 · 2021: 21 · 2020: 9 · 2019: 4
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Research Foundation of Korea
- Ministry of Science, ICT and Future Planning (2015R1c1A1a01056107)
- Korea Electric Power Corporation (R17XA05-15)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Keywords
- bidirectional buck-boost converter, photovoltaic systems, energy storage systems, smart grid, discontinuous conduction mode, zero-voltage switching, output current ripple reduction, power conversion efficiency, auxiliary capacitor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.