An Improved Synchronization Stability Method of Virtual Synchronous Generators Based on Frequency Feedforward on Reactive Power Control Loop
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The synchronization stability of the virtual synchronous generator (VSG) under grid fault is an important issue for maintaining stable operation in the power system. Existing work has pointed out a low-pass filter (LPF) with a sufficiently low cutoff frequency in the reactive power control loop (RPCL) can improve the transient stability. Yet, the underlying mechanism was unknown. Moreover, as a key index of VSG and precondition of synchronization stability, the frequency response is rarely studied. In this article, based on the linearized model for qualitative analysis, combined with the nonlinear model for quantitative analysis, the underlying mechanism of improving synchronization stability using an LPF in the RPCL is revealed. Furthermore, to avoid increasing the system order and solve the conflict between transient stability and frequency response, an improved synchronization stability method is proposed by feedforwarding the frequency difference between the VSG and grid to the RPCL. The frequency response is also acquired based on the combined linearized and nonlinear model, which shows that the frequency feedforward method can further enhance the frequency stability. How to design the coefficient of the frequency feedforward path with different inertia requirements is also presented. Finally, this method is verified by experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“THE penetration of distributed energy resources connected to the electric power system (EPS) by voltage source converters (VSCs) is growing quickly [1]–[3].”
BackgroundSelf-citationSynchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107 · cited 1×
“The first one is virtual synchronous generators (VSGs) [8]–[10], also called as virtual synchronous machines [11] or synchroconverter [12], which directly imitate the mechanical toque equation in the active power control loop (APCL).”
BackgroundLiu, J., Miura, Y., & Ise, T. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465852 · Cited by 1,243 · cited 1×
“It has been proved that these two methods are equivalent to the inertia response [15], [16].”
BackgroundPower System Stabilization Using Virtual Synchronous Generator With Alternating Moment of Inertia
Alipoor, J., Miura, Y., & Ise, T. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2362530 · Cited by 1,039 · cited 1×
“In [29] and [30], an adaptive inertia method is proposed to decrease the frequency deviation during the transient period, which is dependent on detecting the frequency and RoCoF.”
MethodGrid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862 · cited 6×
“synchronization stability problems when the system with power synchronous control has equilibrium points after grid fault [24], [25], due to a first-order response of the APCL.”
BackgroundSelf-citationInertia response and frequency control techniques for renewable energy sources: A review
Dreidy, M., Mokhlis, H., & Mekhilef, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.170 · Cited by 853 · cited 1×
“Besides, lower inertia will cause a high RoCoF, which might trip the generators and lead to cascading failure [5]–[7].”
BackgroundSmall-Signal Modeling and Parameters Design for Virtual Synchronous Generators
Wu, H., Ruan, X., Yang, D., Chen, X., Zhao, W., Lv, Z., & Zhong, Q. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2543181 · Cited by 799 · cited 2×
“stability analysis [19], [20], which are generally assessed by linearizing the system around a steady-state operating point.”
BackgroundOn the Inertia of Future More-Electronics Power Systems
Fang, J., Li, H., Tang, Y. K., & Blaabjerg, F. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2877766 · Cited by 746
Self-citationMeng, X., Liu, J., & Liu, Z. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2868722 · Cited by 708 · cited 2×
“inertia by adding a low-pass filter (LPF) in the APCL [13], [14].”
BackgroundD’Arco, S., Suul, J. A., & Fosso, O. B. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.01.001 · Cited by 704 · cited 4×
“Furthermore, the inertia J should be large enough to maintain the maximum RoCoF in the acceptable range according to the grid code [8].”
BackgroundInfluentialTransient Stability of Voltage-Source Converters With Grid-Forming Control: A Design-Oriented Study
Pan, D., Wang, X., Liu, F., & Shi, R. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2946310 · Cited by 681 · cited 10×
“In [21], it has been revealed that adding an LPF in the RPCL, as shown in Fig.”
BackgroundMethodResultInfluentialPassivity-Based Stability Assessment of Grid-Connected VSCs—An Overview
Harnefors, L., Wang, X., Yepes, A. G., & Blaabjerg, F. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2490549 · Cited by 674
Self-citationDistributed Power-Generation Systems and Protection
Blaabjerg, F., Yang, Y., Yang, D., & Wang, X. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2696878 · Cited by 671
Self-citationTransient Angle Stability of Virtual Synchronous Generators Using Lyapunov’s Direct Method
Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2866122 · Cited by 546 · cited 1×
“In [26] and [27], the transient stability of VSGs can be enhanced by reducing the active power reference and/or increasing the reactive power reference during grid voltage sag.”
BackgroundYuan, H., Yuan, X., & Hu, J. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2653939 · Cited by 378 · cited 1×
“Meanwhile, the inner loop bandwidth is much higher, and the delay term mainly affects the performance of high frequency [35], [36].”
BackgroundWu, H., & Wang, X. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2875669 · Cited by 320
Cheng, H., Shuai, Z., Shen, C., Liu, X., Li, Z., & Shen, Z. J. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2965152 · Cited by 254 · cited 1×
“In [31], an additional damping control method is proposed based on the Lyapunov’s direct method, but the design method for the additional damping coefficient is absent.”
MethodAdjusting Synchronverter Dynamic Response Speed via Damping Correction Loop
Dong, S., & Chen, Y. C. (2017) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2645450 · Cited by 234 · cited 2×
“Substantial research efforts have been devoted to the modeling and stability analysis under different grid conditions [19]–[21], [24]–[32].”
BackgroundWu, H., & Wang, X. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2976791 · Cited by 227 · cited 4×
“Substantial research efforts have been devoted to the modeling and stability analysis under different grid conditions [19]–[21], [24]–[32].”
BackgroundMethodInfluentialModelling, Implementation, and Assessment of Virtual Synchronous Generator in Power Systems
Chen, M., Zhou, D., & Blaabjerg, F. (2020) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000592 · Cited by 205 · cited 1×
“Besides, lower inertia will cause a high RoCoF, which might trip the generators and lead to cascading failure [5]–[7].”
BackgroundSelf-citationIntegration of DC Microgrids as Virtual Synchronous Machines Into the AC Grid
Chen, D., Xu, Y., & Huang, A. Q. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2674621 · Cited by 193
A Unified Modeling Method of Virtual Synchronous Generator for Multi-Operation-Mode Analyses
Liu, J., Miura, Y., Bevrani, H., & Ise, T. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.2970025 · Cited by 144 · cited 1×
“THE penetration of distributed energy resources connected to the electric power system (EPS) by voltage source converters (VSCs) is growing quickly [1]–[3].”
BackgroundYu, H., Awal, M. A., Tu, H., Husain, I., & Lukic, S. M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3007628 · Cited by 119 · cited 2×
“It has been proved that these two methods are equivalent to the inertia response [15], [16].”
BackgroundGrid-Supporting Inverters With Improved Dynamics
Khajehoddin, S. A., Karimi-Ghartemani, M., & Ebrahimi, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2850002 · Cited by 119 · cited 1×
“The first one is virtual synchronous generators (VSGs) [8]–[10], also called as virtual synchronous machines [11] or synchroconverter [12], which directly imitate the mechanical toque equation in the active power control loop (APCL).”
BackgroundPan, P., Chen, W., Shu, L., Mu, H., Zhang, K., Zhu, M., & Deng, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2936527 · Cited by 64 · cited 1×
“In practice, to make an inertia contribution, a large capacitor is added on the dc side, which is controlled by the front-end converter, or the energy storage is generally employed where the dc-link voltage is regulated by an energy storage converter [33], [34].”
BackgroundKrishna, D. G. A., Karthikeyan, A., Prabhakaran, K. K., & Kumar, S. (2020) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2020.3036188 · Cited by 23
Cited by
Wu, X., Wu, S., Wang, F., Wei, C., Li, R., Jiang, X., & Cai, X. (2025) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3510361 · Cited by 24
Metadata
- Authors
- Xiong, X., Wu, C., & Blaabjerg, F.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2021-08
- Volume
- 36
- Issue
- 8
- Pages
- 9136-9148
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3121296716
- Cited by
- 181
- References
- 27
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.