Synchronverter-Based Emulation and Control of HVDC Transmission
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper presents a new control strategy for high voltage direct current (HVDC) transmission based on the synchronverter concept: the sending-end rectifier controls emulate a synchronous motor (SM), and the receiving end inverter emulates a synchronous generator (SG). The two converters connected with a DC line provide what is called a synchronverter HVDC (SHVDC). The structure of the SHVDC is firstly analyzed. It is shown that the droop and voltage regulations included in the SHVDC structure are necessary and sufficient to well define the behavior of SHVDC. The standard parameters of the SG cannot be directly used for this structure. A specific tuning method of these parameters is proposed in order to satisfy the usual HVDC control requirements. The new tuning method is compared with the standard vector control in terms of local performances and fault critical clearing time (CCT) in the neighboring zone of the link. The test network is a 4-machine power system with parallel HVDC/AC transmission. The results indicate the contribution of the proposed controller to enhance the stability margin of the neighbor AC zone of the link.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Rogers, G. J. (2000) · Springer eBooks · doi:10.1007/978-1-4615-4561-3 · Cited by 1,682
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
Virtual synchronous generators
Driesen, J., & Visscher, K. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596800 · Cited by 763
Improving the grid power quality using virtual synchronous machines
Chen, Y., Hesse, R., Turschner, D., & Beck, H.-P. (2011) · 2011 International Conference on Power Engineering, Energy and Electrical Drives · doi:10.1109/powereng.2011.6036498 · Cited by 276
Wang, F., Tjernberg, L. B., Le, T., Mannikoff, A., & Bergman, A. (2011) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 54
Bourlès, H., & Marinescu, B. (2011) · Lecture notes in control and information sciences · doi:10.1007/978-3-642-19727-7 · Cited by 30 · cited 2×
“From [17], the integer is the rank of the module , which coincides with the rank of the linear system .”
BackgroundMethodSelf-citation
Cited by
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
A comprehensive review of virtual synchronous generator
Cheema, K. M. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.106006 · Cited by 288
Jia, J., Yang, G., & Nielsen, A. H. (2018) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2017.2682164 · Cited by 219
Robust Stability Analysis of Synchronverters Operating in Parallel
Rosso, R., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2896707 · Cited by 117
Robust Stability Analysis of LCL Filter Based Synchronverter Under Different Grid Conditions
Rosso, R., Cassoli, J., Buticchi, G., Engelken, S., & Liserre, M. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2867040 · Cited by 89
“Pole placement at prescribed locations in order to achieve desired dynamic has been proposed as optimal tuning procedure [11], [12] and eigenvalue analysis is the commonly adopted approach for investigation of stability of gridconnected converters and design purposes [13].”
BackgroundMethodEvaluation of Virtual Inertia Control Strategies for MMC-based HVDC Terminals by P-HiL Experiments
D'Arco, S., Nguyen, T. T., & Suul, J. A. (2019) · IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2019.8927704 · Cited by 12
Zhou, X., Zhang, L., Peng, H., Hong, L., Xu, Q., Zhang, Z., Shao, J., Ma, J., & Hu, Y. (2026) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2026.111659 · Cited by 8
Metadata
- Authors
- Aouini, R., Marinescu, B., Ben Kilani, K., & Elleuch, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2016-01
- Volume
- 31
- Issue
- 1
- Pages
- 278-286
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2092676196
- Cited by
- 170
- References
- 10
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.