Understanding Small-Signal Stability of Low-Inertia Systems
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Large-scale integration of renewable generation, usually interfaced to the network through power electronics, has led to drastic changes in power system dynamics. This paper presents novel insights into stability properties of such systems. For that purpose, a high-fidelity dynamic model of a generic low-inertia power system has been developed. The full-order, state-of-the-art control schemes of both synchronous and converter-based generators are included, with the latter differentiating between grid-forming and grid-following mode of operation. Furthermore, the dynamics of transmission lines and loads are captured in the model. Using modal analysis techniques such as participation factors and parameter sensitivity, the most vulnerable segments of the system are determined and the adverse effects of timescale coupling and control interference are investigated. More precisely, this work characterizes the maximum permissible penetration levels of inverter-based generation as well as the nature of the associated unstable modes and the underlying dynamics. Finally, potential directions for improving the system stability margin under different generation portfolios are proposed for several benchmark systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
Power system dynamics : stability and control
Machowski, J., Bialek, J. W., & Bumby, J. R. (2008) · Durham Research Online (Durham University) · Cited by 2,348
Power System Dynamics and Stability
Sauer, P. W., & Pai, M. A. (1997) · Cited by 2,154
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
Self-citationSynchronization and power sharing for droop-controlled inverters in islanded microgrids
Simpson-Porco, J. W., Dörfler, F., & Bullo, F. (2013) · Automatica · doi:10.1016/j.automatica.2013.05.018 · Cited by 832
Power System Control and Stability
Anderson, P. M., Fouad, A. A., & Happ, H. H. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310158 · Cited by 699
Gautam, D., Vittal, V., & Harbour, T. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2021234 · Cited by 680
Small-signal stability for parallel-connected inverters in stand-alone AC supply systems
Coelho, E. A. A., Cortizo, P. C., & Garcia, P. F. D. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993176 · Cited by 662
D'Arco, S., & Suul, J. A. (2013) · 2013 IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652456 · Cited by 443
Conditions for stability of droop-controlled inverter-based microgrids
Schiffer, J., Ortega, R., Astolfi, A., Raisch, J., & Sezi, T. (2014) · Automatica · doi:10.1016/j.automatica.2014.08.009 · Cited by 434
Poolla, B. K., Gros, D., & Dorfler, F. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2892290 · Cited by 400
The impact of large scale wind power generation on power system oscillations
Slootweg, J. G., & Kling, W. L. (2003) · Electric Power Systems Research · doi:10.1016/s0378-7796(03)00089-0 · Cited by 392
Evaluation of Virtual Synchronous Machines With Dynamic or Quasi-Stationary Machine Models
Mo, O., D’Arco, S., & Suul, J. A. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2638810 · Cited by 299
Grid-forming control for power converters based on matching of synchronous machines
Arghir, C., Jouini, T., & Dörfler, F. (2018) · Automatica · doi:10.1016/j.automatica.2018.05.037 · Cited by 263
Guo, X., Lu, Z., Wang, B., Sun, X., Wang, L., & Guerrero, J. M. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2331280 · Cited by 259
A Generalized Computational Method to Determine Stability of a Multi-inverter Microgrid
Iyer, S. V., Belur, M. N., & Chandorkar, M. C. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2048720 · Cited by 257
On the Stability of Power Electronics-Dominated Systems: Challenges and Potential Solutions
Peng, Q., Jiang, Q., Yang, Y., Liu, T., Wang, H., & Blaabjerg, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2936788 · Cited by 243
High-Fidelity Model Order Reduction for Microgrids Stability Assessment
Vorobev, P., Huang, P.-H., Al Hosani, M., Kirtley, J. L., & Turitsyn, K. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2707400 · Cited by 205
Colombino, M., Groß, D., Brouillon, J.-S., & Dörfler, F. (2019) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2019.2898549 · Cited by 199
The Effect of Transmission-Line Dynamics on Grid-Forming Dispatchable Virtual Oscillator Control
Gros, D., Colombino, M., Brouillon, J.-S., & Dorfler, F. (2019) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2019.2921347 · Cited by 168
Voltage Stabilization in Microgrids via Quadratic Droop Control
Simpson-Porco, J. W., Dorfler, F., & Bullo, F. (2017) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2016.2585094 · Cited by 166
Model Order Reductions for Stability Analysis of Islanded Microgrids With Droop Control
Mariani, V., Vasca, F., Vasquez, J. C., & Guerrero, J. M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2381151 · Cited by 162
Dynamic Stability Calculations for an Arbitrary Number of Interconnected Synchronous Machines
Uudrill, J. (1968) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1968.292199 · Cited by 161
Moeini, A., Kamwa, I., Brunelle, P., & Sybille, G. (2015) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2015.7339813 · Cited by 156
Tuning of Cascaded Controllers for Robust Grid-Forming Voltage Source Converter
Qoria, T., Gruson, F., Colas, F., Guillaud, X., Debry, M.-S., & Prévost, T. (2018) · Power Systems Computation Conference · doi:10.23919/pscc.2018.8443018 · Cited by 145
Small-Signal Stability Analysis of an Inverter-Based Microgrid With Internal Model-Based Controllers
Leitner, S., Yazdanian, M., Mehrizi‐Sani, A., & Muetze, A. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2688481 · Cited by 143
Stability Evaluation of Interconnected Multi-Inverter Microgrids Through Critical Clusters
Nikolakakos, I. P., Zeineldin, H. H., Moursi, M. S. E., & Hatziargyriou, N. D. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2476826 · Cited by 132
Small-signal modelling and parametric sensitivity of a Virtual Synchronous Machine
D’Arco, S., Suul, J. A., & Fosso, O. B. (2014) · Power Systems Computation Conference · doi:10.1109/pscc.2014.7038410 · Cited by 127
Survivability of Autonomous Microgrid During Overload Events
Du, W., Lasseter, R. H., & Khalsa, A. S. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2829438 · Cited by 122
Pourbeik, P., Sanchez-Gasca, J. J., Senthil, J., Weber, J. D., Zadkhast, P., Kazachkov, Y., Tacke, S., Wen, J. X., & Ellis, A. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2639050 · Cited by 120
Díaz, G., González‐Morán, C., Gómez‐Aleixandre, J., & Díez, A. B. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2030396 · Cited by 86
Jouini, T. K., Arghir, C., & Dörfler, F. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.10.395 · Cited by 79
Increasing the Resilience of Low-inertia Power Systems by Virtual Inertia and Damping
Groß, D., Bolognani, S., Poolla, B. K., & Dörfler, F. (2017) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000232185 · Cited by 58
Voltage stabilization in microgrids via quadratic droop control
Simpson-Porco, J. W., Dörfler, F., & Bullo, F. (2013) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2013.6761093 · Cited by 55
Improving Dynamic Performance of Low-Inertia Systems Through Eigensensitivity Optimization
Venkatraman, A., Markovic, U., Shchetinin, D., Vrettos, E., Aristidou, P., & Hug, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3062974 · Cited by 53
Self-citationA System Reference Frame Approach for Stability Analysis and Control of Power Grids
Spanias, C., & Lestas, I. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2872549 · Cited by 26
Stabilising control strategy for cyber‐physical power systems
Ekomwenrenren, E., Alharbi, H. A., El-Gorashi, T. E. H., Elmirghani, J. M. H., & Aristidou, P. (2019) · IET Cyber-Physical Systems Theory & Applications · doi:10.1049/iet-cps.2018.5020 · Cited by 20
Self-citationPinares, G. (2014) · Power Systems Computation Conference · doi:10.1109/pscc.2014.7038406 · Cited by 14
Small-Signal analysis of an isolated power system controlled by a virtual synchronous machine
D’Arco, S., & Suul, J. A. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/epepemc.2016.7752041 · Cited by 14
Cited by
Grid Forming Inverter Modeling, Control, and Applications
Rathnayake, D. B., Akrami, M., Phurailatpam, C., Me, S. P., Hadavi, S., Jayasinghe, G., Zabihi, S., & Bahrani, B. (2021) · IEEE Access · doi:10.1109/access.2021.3104617 · Cited by 630
An Adaptive BESS Controller for Stability Enhancement of Islanded Low Voltage Microgrids
Som, S., Chakrabarti, S., & Sahoo, S. R. (2024) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2023.3345489 · Cited by 11
“However, this will drastically reduce system inertia and lead to a large rate of change of frequency during system disturbances [5].”
BackgroundWang, X., & Chen, X. (2026) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2026.3684791
“1) Grid-Forming Inverters: We consider droop control-based GFM inverters [40], and the dynamic model is given by (1) for bus i ∈ N M : where ω i denotes the frequency deviation from the nominal value at bus i .”
Metadata
- Authors
- Markovic, U., Stanojev, O., Aristidou, P., Vrettos, E., Callaway, D., & Hug, G.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2021-09
- Volume
- 36
- Issue
- 5
- Pages
- 3997-4017
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3129624334
- Cited by
- 370
- References
- 44
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.