The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User–Prosthesis Interaction
Abstract
An anthropomorphic underactuated prosthetic hand, endowed with position and force sensors and controlled by means of myoelectric commands, is used to perform experiments of hierarchical shared control. Three different hierarchical control strategies combined with a vibrotactile feedback system have been developed and tested by able-bodied subjects through grasping tasks used in activities of daily living (ADLs). The first goal is to find a good tradeoff between good grasping capabilities and low attention required by the user to complete grasping tasks, without addressing advanced algorithm for electromyographic processing. The second goal is to understand whether a vibrotactile feedback system is subjectively or objectively useful and how it changes users' performance. Experiments showed that users were able to successfully operate the device in the three control strategies, and that the grasp success increased with more interactive control. Practice has proven that when too much effort is required, subjects do not do their best, preferring, instead, a less-interactive control strategy. Moreover, the experiments showed that when grasping tasks are performed under visual control, the enhanced proprioception offered by a vibrotactile system is practically not exploited. Nevertheless, in subjective opinion, feedback seems to be quite important.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1932) · Medical Entomology and Zoology · Cited by 9,568
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
THE PREHENSILE MOVEMENTS OF THE HUMAN HAND
Napier, J. R. (1956) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.38b4.902 · Cited by 1,571
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Orthopedic Physical Assessment
Magee, D. J. (1987) · Cited by 1,062
Robot Hands and the Mechanics of Manipulation
Mason, M. T., Salisbury, J. K., & Parker, J. K. (1989) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3153010 · Cited by 911
Analysis of Multifingered Hands
Kerr, J., & Roth, B. (1986) · The International Journal of Robotics Research · doi:10.1177/027836498600400401 · Cited by 897
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606
Self-citationDirect neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Self-citationEpidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities
Atkins, D. J., Heard, D. C. Y., & Donovan, W. H. (1996) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-199600810-00003 · Cited by 508
Light, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417
Design of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
Self-citationSchema design and implementation of the grasp-related mirror neuron system
Oztop, E., & Arbib, M. A. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0318-1 · Cited by 307
A new ultralight anthropomorphic hand
Schulz, S., Pylatiuk, C., & Bretthauer, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932988 · Cited by 189
Development of a lightweight and adaptable multiple-axis hand prosthesis
Light, C. M., & Chappell, P. H. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00017-0 · Cited by 178
Sensory Input and Control of Grip
Johansson, R. S. (2007) · Novartis Foundation Symposia · doi:10.1002/9780470515563.ch4 · Cited by 165
Myoelectric prostheses. A long-term follow-up and a study of the use of alternate prostheses.
Silcox, D. H., Rooks, M. D., Vogel, R., & Fleming, L. L. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199312000-00007 · Cited by 144
MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control
Kyberd, P., Holland, O. E., Chappell, P. H., Smith, S., Tregidgo, R., Bagwell, P. J., & Snaith, M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.372895 · Cited by 121
The development of a novel prosthetic hand-ongoing research and preliminary results
Carrozza, M. C., Massa, B., Micera, S., Lazzarini, R., Zecca, M., & Dario, P. (2002) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2002.1011247 · Cited by 120
Self-citationFactors related to successful upper extremity prosthetic use
Roeschlein, R. A., & Domholdt, E. (1989) · Prosthetics and Orthotics International · doi:10.3109/03093648909079404 · Cited by 106
Progress in the development of a multifunctional hand prosthesis
Pylatiuk, C., Mounier, S., Kargov, A., Schulz, S., & Bretthauer, G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404187 · Cited by 88
SENSORY SUBSTITUTION IN PROSTHETICS
Lundborg, G., & Rosén, B. (2001) · Hand Clinics · doi:10.1016/s0749-0712(21)00526-6 · Cited by 81
Hybrid Bionic Systems for the Replacement of Hand Function
Micera, S., Carrozza, M. C., Beccai, L., Vecchi, F., & Dario, P. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.881294 · Cited by 73
Self-citationSensory and Memory Information in the Control of Dexterous Manipulation
Johansson, R. S. (1996) · Springer eBooks · doi:10.1007/978-94-017-2403-6_10 · Cited by 57
Closed-loop controller for a bio-inspired multi-fingered underactuated prosthesis
Cipriani, C., Zaccone, F., Stellin, G., Beccai, L., Cappiello, G., Carrozza, M. C., & Dario, P. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642016 · Cited by 46
Self-citationCognitive feedback for use with FES upper extremity neuroprostheses
Riso, R. R., Ignagni, A. R., & Keith, M. W. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68206 · Cited by 35
Some Aspects of Nonstationary Myoelectric Signal Processing
Xiong, F., & Shwedyk, E. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326041 · Cited by 29
Characterization of tfLIFE Neural Response for the Control of a Cybernetic Hand
Citi, L., Carpaneto, J., Yoshida, K., Hoffmann, K. ‐., Koch, K. P., Dario, P., & Micera, S. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639134 · Cited by 21
Self-citationA microfabricated interface for neural recording and stimulation
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, J.-U., Valderrama, E., Sebastiani, L., Ghelarducci, B., & Pastacaldi, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/041 · Cited by 15
Self-citationSensory feedback system using interferential current for EMG prosthetic hand
Sasaki, Y. C., Nakayama, Y., & Yoshida, M. (2002) · doi:10.1109/iembs.2002.1053345 · Cited by 14
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Self-citationMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Self-citationDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationHegde, C., Su, J., Tan, J. M. R., He, K., Chen, X., & Magdassi, S. (2023) · ACS Nano · doi:10.1021/acsnano.3c04089 · Cited by 384
Metadata
- Authors
- Cipriani, C., Zaccone, F., Micera, S., & Carrozza, M. C.
- Venue
- IEEE Transactions on Robotics
- Published
- 2008-02
- Volume
- 24
- Issue
- 1
- Pages
- 170-184
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2133644836
- Cited by
- 453
- References
- 34
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.