The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Open accessAbstract
At moderate to fast walking speeds, the human ankle provides net positive work at high-mechanical-power output to propel the body upward and forward during the stance period. On the contrary, conventional ankle-foot prostheses exhibit a passive-elastic response during stance, and consequently, cannot provide net work. Clinical studies indicate that transtibial amputees using conventional prostheses have higher gait metabolic rates than normal. Researchers believe that the main cause for these higher rates is due to the inability of conventional prostheses to provide sufficient positive power at terminal stance in the trailing leg to limit heel strike losses of the adjacent leading leg. In this investigation, we evaluate the hypothesis that a powered ankle-foot prosthesis, capable of providing human-like ankle work and power during stance, can decrease the metabolic cost of transport (COT) compared to a conventional passive-elastic prosthesis. To test the hypothesis, a powered prosthesis is built that comprises a unidirectional spring, configured in parallel with a force-controllable actuator with series elasticity. The prosthesis is shown to deliver the high mechanical power and net positive work observed in normal human walking. The rate of oxygen consumption and carbon dioxide production is measured as a determinant of metabolic rate on three unilateral transtibial amputees walking at self-selected speeds. We find that the powered prosthesis decreases the amputee's metabolic COT on average by 14% compared to the conventional passive-elastic prostheses evaluated (Flex-Foot Ceterusregand Freedom Innovations Sierra), even though the powered system is over twofold heavier than the conventional devices. These results highlight the clinical importance of prosthetic interventions that closely mimic the mass distribution, kinetics, and kinematics of the missing limb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
The development of Honda humanoid robot
Hirai, K., Hirose, M., Haikawa, Y., & Takenaka, T. (2002) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.677288 · Cited by 1,922
Kaneko, K., Kanehiro, F., Kajita, S., Hirukawa, H., Kawasaki, T., Hirata, M., Akachi, K., & Isozumi, T. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307969 · Cited by 759
Energetics of Actively Powered Locomotion Using the Simplest Walking Model
Kuo, A. D. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427703 · Cited by 736
An integrated biomechanical analysis of normal stair ascent and descent
McFadyen, B. J., & Winter, D. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90282-5 · Cited by 693
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Derivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Biomechanical Motor Patterns in Normal Walking
Winter, D. A. (1983) · Journal of Motor Behavior · doi:10.1080/00222895.1983.10735302 · Cited by 530
Biomechanics of below-knee amputee gait
Winter, D. A., & Sienko, S. E. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90142-x · Cited by 521
Measure of Man and Woman: Human Factors in Design
Tilley, A. R. (1993) · Cumulative Index of Computer Aided Architectural Design · Cited by 451
Ruina, A., Bertram, J. E. A., & Srinivasan, M. (2005) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.04.004 · Cited by 433
The human ankle during walking: implications for design of biomimetic ankle prostheses
Hansen, A. H., Childress, D. S., Miff, S. C., Gard, S. A., & Mesplay, K. P. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.01.017 · Cited by 347
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Self-citationDesign and analysis of series elasticity in closed-loop actuator force control
Robinson, D. W. (2000) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 265
Robotics and Automation Handbook
(2004) · CRC Press eBooks · doi:10.1201/9781420039733 · Cited by 229
Calf muscle moment, work and efficiency in level walking; Role of series elasticity
Hof, A. L., Geelen, B. A., & Van den Berg, J. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90067-2 · Cited by 209
The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise
Hausswirth, C., Bigard, A., & Le Chevalier, J. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972662 · Cited by 193
Powered Ankle-Foot Prosthesis for the Improvement of Amputee Ambulation
Au, S. K., Herr, H., Weber, J., & Martinez-Villalpando, E. C. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352965 · Cited by 182
Self-citationKinematic and Kinetic Variations of Below-Knee Amputee Gait
Bateni, H., & Olney, S. J. (2002) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200203000-00003 · Cited by 173
Activity Levels Among Lower-Limb Amputees: Self-Report Versus Step Activity Monitor
Stepien, J. M., Cavenett, S., Taylor, L., & Crotty, M. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.03.016 · Cited by 163
Sagittal plane characterization of normal human ankle function across a range of walking gait speeds
Palmer, M. L. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 160
Biomechanical Design of a Powered Ankle-Foot Prosthesis
Au, S. K., Weber, J., & Herr, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428441 · Cited by 158
Self-citationAn EMG-Position Controlled System for an Active Ankle-Foot Prosthesis: An Initial Experimental Study
Au, S. K., Bonato, P., & Herr, H. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501123 · Cited by 147
Self-citationColborne, G., Naumann, S., Longmuir, P. E., & Berbrayer, D. (1992) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199210000-00004 · Cited by 132
Energy/speed relation of below-knee amputees walking on a motor-driven treadmill
Molen, N. H. (1973) · European Journal of Applied Physiology · doi:10.1007/bf00697597 · Cited by 122
Impedance and Interaction Control
Hogan, N., & Buerger, S. P. (2018) · doi:10.1201/9781315220352-22 · Cited by 107
Finite-state control of a trans-femoral (TF) prosthesis
Zlatnik, D., Steiner, B., & Schweitzer, G. (2002) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.998030 · Cited by 84
Prosthetics and Orthotics: Lower Limb and Spine
Seymour, R. (2002) · Medical Entomology and Zoology · Cited by 78
Hitt, J. K., Bellman, R. D., Holgate, M. A., Sugar, T. G., & Hollander, K. W. (2007) · doi:10.1115/detc2007-34512 · Cited by 78
Versluys, R., Desomer, A., Lenaerts, G., Damme, M. V., Beyl, P., der Perre, G. V., Peeraer, L., & Lefeber, D. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762842 · Cited by 53
Research and Development of the Intelligently-Controlled Prosthetic Ankle Joint
Li, C., TOKUDA, M., FURUSHO, J., Koyanagi, K., Morimoto, S., Hashimoto, Y., Nakagawa, A., & AKAZAWA, Y. (2006) · International Conference on Mechatronics and Automation · doi:10.1109/icma.2006.257781 · Cited by 39
Biomimetic Design of an Under-Actuated Leg Exoskeleton for Load-Carrying Augmentation
Walsh, C. J. (2006) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 31
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Relative to their passive counterparts, active P/Os also have the potential to increase self-selected gait speed while reducing metabolic expenditure [2-4].”
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Self-citationControl of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model
Eilenberg, M. F., Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039620 · Cited by 419
Self-citationBionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Self-citation
Metadata
- Authors
- Au, S. K., Weber, J., & Herr, H.
- Venue
- IEEE Transactions on Robotics
- Published
- 2009-02
- Volume
- 25
- Issue
- 1
- Pages
- 51-66
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2098682658
- Cited by
- 487
- References
- 36
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.