The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Powered Ankle--Foot Prosthesis Improves Walking Metabolic Economy
Open accessAbstract
At moderate to fast walking speeds, the human ankle provides net positive work at high-mechanical-power output to propel the body upward and forward during the stance period. On the contrary, conventional ankle-foot prostheses exhibit a passive-elastic response during stance, and consequently, cannot provide net work. Clinical studies indicate that transtibial amputees using conventional prostheses have higher gait metabolic rates than normal. Researchers believe that the main cause for these higher rates is due to the inability of conventional prostheses to provide sufficient positive power at terminal stance in the trailing leg to limit heel strike losses of the adjacent leading leg. In this investigation, we evaluate the hypothesis that a powered ankle-foot prosthesis, capable of providing human-like ankle work and power during stance, can decrease the metabolic cost of transport (COT) compared to a conventional passive-elastic prosthesis. To test the hypothesis, a powered prosthesis is built that comprises a unidirectional spring, configured in parallel with a force-controllable actuator with series elasticity. The prosthesis is shown to deliver the high mechanical power and net positive work observed in normal human walking. The rate of oxygen consumption and carbon dioxide production is measured as a determinant of metabolic rate on three unilateral transtibial amputees walking at self-selected speeds. We find that the powered prosthesis decreases the amputee's metabolic COT on average by 14% compared to the conventional passive-elastic prostheses evaluated (Flex-Foot Ceterusregand Freedom Innovations Sierra), even though the powered system is over twofold heavier than the conventional devices. These results highlight the clinical importance of prosthetic interventions that closely mimic the mass distribution, kinetics, and kinematics of the missing limb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
The development of Honda humanoid robot
Hirai, K., Hirose, M., Haikawa, Y., & Takenaka, T. (2002) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.677288 · Cited by 1,922
Kaneko, K., Kanehiro, F., Kajita, S., Hirukawa, H., Kawasaki, T., Hirata, M., Akachi, K., & Isozumi, T. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307969 · Cited by 759
Energetics of Actively Powered Locomotion Using the Simplest Walking Model
Kuo, A. D. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427703 · Cited by 736
An integrated biomechanical analysis of normal stair ascent and descent
McFadyen, B. J., & Winter, D. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90282-5 · Cited by 693
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Relative to their passive counterparts, active P/Os also have the potential to increase self-selected gait speed while reducing metabolic expenditure [2-4].”
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
“It is important to mention that classical and modern synthesis techniques have been recently used in the design and implementation of controllers for active hard robotic prosthetic systems [38, 41, 42, 48–50].”
MethodPowered ankle-foot prosthesis to assist level-ground and stair-descent gaits
Au, S., Berniker, M., & Herr, H. (2008) · Neural Networks · doi:10.1016/j.neunet.2008.03.006 · Cited by 487
Self-citationControl of a Powered Ankle–Foot Prosthesis Based on a Neuromuscular Model
Eilenberg, M. F., Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039620 · Cited by 419
Self-citationBionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Self-citationModels, feedback control, and open problems of 3D bipedal robotic walking
Grizzle, J. W., Chevallereau, C., Sinnet, R. W., & Ames, A. D. (2014) · Automatica · doi:10.1016/j.automatica.2014.04.021 · Cited by 321
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Self-citationActive lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Charkhkar, H., Shell, C. E., Marasco, P. D., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aac964 · Cited by 131
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
A Locomotion Intent Prediction System Based on Multi-Sensor Fusion
Chen, B., Zheng, E., & Wang, Q. (2014) · Sensors · doi:10.3390/s140712349 · Cited by 69
“Though they are widely used, they have inevitable deficiencies such as more metabolic power consumption and asymmetrical gait pattern [1].”
BackgroundXu, D., Feng, Y., Mai, J., & Wang, Q. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2870152 · Cited by 67
“more natural gaits can be acquired with robotic prosthesis [1]–[4].”
Background
Metadata
- Authors
- Au, S. K., Weber, J., & Herr, H.
- Venue
- IEEE Transactions on Robotics
- Published
- 2009-02
- Volume
- 25
- Issue
- 1
- Pages
- 51-66
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2098682658
- Cited by
- 487
- References
- 36
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.