The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Robot-Aided Neurorehabilitation: A Novel Robot for Ankle Rehabilitation
Open accessAbstract
In this paper, we present the design and characterization of a novel ankle robot developed at the Massachusetts institute of technology (MIT). This robotic module is being tested with stroke patients at Baltimore Veterans administration medical center. The purpose of the on-going study is to train stroke survivors to overcome common foot drop and balance problems in order to improve their ambulatory performance. Its design follows the same guidelines of our upper extremity designs, i.e., it is a low friction, backdriveable device with intrinsically low mechanical impedance. Here, we report on the design and mechanical characteristics of the robot. We also present data to demonstrate the potential of this device as an efficient clinical measurement tool to estimate intrinsic ankle properties. Given the importance of the ankle during locomotion, an accurate estimate of ankle stiffness would be a valuable asset for locomotor rehabilitation. Our initial ankle stiffness estimates compare favorably with previously published work, indicating that our method may serve as an accurate clinical measurement tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Neural, mechanical, and geometric factors subserving arm posture in humans
Mussa-Ivaldi, F., Hogan, N., & Bizzi, E. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-10-02732.1985 · Cited by 1,158
Self-citationTreadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Running in the real world: adjusting leg stiffness for different surfaces
Ferris, D. P., Louie, M., & Farley, C. T. (1998) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1998.0388 · Cited by 594
A novel approach to stroke rehabilitation: Robot-aided sensorimotor stimulation
Volpe, B. T., Krebs, H. I., Hogan, N., Edelstein, L., Diels, C., & Aisen, M. (2000) · Neurology · doi:10.1212/wnl.54.10.1938 · Cited by 582
Self-citationElectromechanical-assisted training for walking after stroke
Mehrholz, J., Thomas, S., Werner, C., Kugler, J., Pohl, M., & Elsner, B. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub4 · Cited by 564
Effects of robotic therapy on motor impairment and recovery in chronic stroke
Fasoli, S. E., Krebs, H. I., Stein, J., Frontera, W. R., & Hogan, N. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2003.50110 · Cited by 512
Self-citationLoram, I. D., & Lakie, M. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.025049 · Cited by 496
Mechanism of leg stiffness adjustment for hopping on surfaces of different stiffnesses
Farley, C. T., Houdijk, H. H. P., Van Strien, C., & Louie, M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.3.1044 · Cited by 455
Increasing productivity and quality of care: robot-aided neuro-rehabilitation.
Krebs, H. I., Volpe, B. T., Aisen, M. L., & Hogan, N. (2000) · PubMed · Cited by 441
Self-citationMuscle stiffness in human ankle dorsiflexors: intrinsic and reflex components
Sinkjaer, T., Toft, E., Andreassen, S., & Hornemann, B. C. (1988) · Journal of Neurophysiology · doi:10.1152/jn.1988.60.3.1110 · Cited by 425
Jenkins, W. M., & Merzenich, M. M. (1987) · Progress in Brain Research · doi:10.1016/s0079-6123(08)61829-4 · Cited by 398
Interaction of leg stiffness and surface stiffness during human hopping
Ferris, D. P., & Farley, C. T. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.15 · Cited by 395
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2000) · PubMed · Cited by 388
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
The human ankle during walking: implications for design of biomimetic ankle prostheses
Hansen, A. H., Childress, D. S., Miff, S. C., Gard, S. A., & Mesplay, K. P. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.01.017 · Cited by 347
Pohl, M., Werner, C., Holzgraefe, M., Kroczek, G., Wingendorf, I., Hoölig, G., Koch, R., & Hesse, S. (2007) · Clinical Rehabilitation · doi:10.1177/0269215506071281 · Cited by 340
MIT-MANUS: a workstation for manual therapy and training. I
Hogan, N., Krebs, H. I., Charnnarong, J., Srikrishna, P., & Sharon, A. (2003) · [1992] Proceedings IEEE International Workshop on Robot and Human Communication · doi:10.1109/roman.1992.253895 · Cited by 314
Self-citationRobot training enhanced motor outcome in patients with stroke maintained over 3 years
Volpe, B. T., Krebs, H. I., Hogan, N., Edelsteinn, L., Diels, C. M., & Aisen, M. L. (1999) · Neurology · doi:10.1212/wnl.53.8.1874 · Cited by 276
Self-citationRobot-aided sensorimotor arm training improves outcome in patients with chronic stroke
Ferraro, M., Palazzolo, J. J., Krol, J., Krebs, H. I., Hogan, N., & Volpe, B. T. (2003) · Neurology · doi:10.1212/01.wnl.0000095963.00970.68 · Cited by 242
Self-citationRobotic therapy for chronic motor impairments after stroke: follow-up results
Fasoli, S. E., Krebs, H. I., Stein, J., Frontera, W. R., Hughes, R., & Hogan, N. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.028 · Cited by 239
Self-citationA Stewart Platform-Based System for Ankle Telerehabilitation
Girone, M., Burdea, G., Bouzit, M., Popescu, V., & Deutsch, J. E. (2001) · Autonomous Robots · doi:10.1023/a:1008938121020 · Cited by 236
Intrinsic and reflex stiffness in normal and spastic, spinal cord injured subjects
M., M., H., B., M., L., & R., K. (2001) · Experimental Brain Research · doi:10.1007/s00221-001-0901-z · Cited by 228
Large-scale plasticity of the human motor cortex
Seitz, R. J., Huang, Y., Knorr, U., Tellmann, L., Herzog, H., & Freund, H.-J. (1995) · NeuroReport · doi:10.1097/00001756-199503270-00009 · Cited by 217
Is robot-aided sensorimotor training in stroke rehabilitation a realistic option?
Volpe, B. T., Krebs, H. I., & Hogan, N. (2001) · Current Opinion in Neurology · doi:10.1097/00019052-200112000-00011 · Cited by 209
Self-citationSpasticity causes a fundamental rearrangement of muscle–joint interaction
Lieber, R. L., & Fridén, J. (2002) · Muscle & Nerve · doi:10.1002/mus.10036 · Cited by 209
Comparison of Two Techniques of Robot-Aided Upper Limb Exercise Training After Stroke
Stein, J., Krebs, H. I., Frontera, W. R., Fasoli, S. E., Hughes, R., & Hogan, N. (2004) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000137313.14480.ce · Cited by 201
Self-citationA mechanized gait trainer for restoring gait in nonambulatory subjects
Hesse, S., Uhlenbrock, D., Werner, C., & Bardeleben, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.6280 · Cited by 193
Intelligent stretching of ankle joints with contracture/spasticity
Zhang, L., Chung, S. G., Bai, Z., Xu, D., van Rey, E. M., Rogers, M. W., Johnson, M., & Roth, E. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.802857 · Cited by 157
Electromechanical-assisted training for walking after stroke
Mehrholz, J., Werner, C., Kügler, J., & Pohl, M. (2007) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006185.pub2 · Cited by 156
Therapeutic Robotics: A Technology Push
Krebs, H. I., & Hogan, N. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880721 · Cited by 138
Self-citationIN VIVO THREE-DIMENSIONAL KINEMATICS OF THE MIDCARPAL JOINT OF THE WRIST
Moritomo, H., MURASE, T., GOTO, A., OKA, K., SUGAMOTO, K., & YOSHIKAWA, H. (2006) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200603000-00021 · Cited by 127
The validity and reliability of a test of lower body musculotendinous stiffness
Walshe, A. D., Wilson, G. J., & Murphy, A. J. (1996) · European Journal of Applied Physiology · doi:10.1007/bf02425495 · Cited by 118
Salsich, G. B., Mueller, M. J., & Sahrmann, S. A. (2000) · Physical Therapy · doi:10.1093/ptj/80.4.352 · Cited by 98
Stochastic Estimation of Arm Mechanical Impedance During Robotic Stroke Rehabilitation
Palazzolo, J. J., Ferraro, M., Krebs, H. I., Lynch, D., Volpe, B. T., & Hogan, N. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891392 · Cited by 91
Self-citationMeasurement of Human Ankle Stiffness Using the Anklebot
Roy, A., Krebs, H. I., Patterson, S. L., Judkins, T. N., Khanna, I., Forrester, L. W., Macko, R., & Hogan, N. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428450 · Cited by 85
Self-citationChung, S. G., van Rey, E. M., Bai, Z., Rymer, W. Z., Roth, E. J., & Zhang, L. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.09.051 · Cited by 71
Hyperactive tendon reflexes in spastic multiple sclerosis: Measures and mechanisms of action
Zhang, L.-Q., Wang, G., Nishida, T., Xu, D., Sliwa, J. A., & Rymer, W. Z. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.5582 · Cited by 54
An ankle robot for a modular gait rehabilitation system
Wheeler, J. W., Krebs, H. I., & Hogan, N. (2005) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2004.1389637 · Cited by 48
Self-citationValidity and reliability of a new in vivo ankle stiffness measurement device
Zinder, S. M., Granata, K. P., Padua, D. A., et al. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.12.007 · Cited by 42
Singer, B., Dunne, J. W., Singer, K. P., et al. (2002) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00116-4 · Cited by 33
■ REVIEW : Plasticity in the Human Motor System
Hallett, M. (1999) · The Neuroscientist · doi:10.1177/107385849900500518 · Cited by 32
Plasticity of the Human Motor System
Hallett, M. (2001) · Cited by 5
Cited by
Design and control of a bio-inspired soft wearable robotic device for ankle–foot rehabilitation
Park, Y.-L., Chen, B.-R., Pérez-Arancibia, N. O., Young, D., Stirling, L., Wood, R. J., Goldfield, E. C., & Nagpal, R. (2014) · Bioinspiration & Biomimetics · doi:10.1088/1748-3182/9/1/016007 · Cited by 497
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
Bosecker, C., Dipietro, L., Volpe, B., & Igo Krebs, H. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309343214 · Cited by 300
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Metadata
- Authors
- Roy, A., Krebs, H. I., Williams, D. J., Bever, C. T., Forrester, L. W., Macko, R. M., & Hogan, N.
- Venue
- IEEE Transactions on Robotics
- Published
- 2009-06
- Volume
- 25
- Issue
- 3
- Pages
- 569-582
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2101892505
- Cited by
- 337
- References
- 44
- FWCI
- 9.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.