Ultrafast compound doppler imaging: providing full blood flow characterization
Abstract
Doppler-based flow analysis methods require acquisition of ultrasound data at high spatio-temporal sampling rates. These rates represent a major technical challenge for ultrasound systems because a compromise between spatial and temporal resolution must be made in conventional approaches. Consequently, ultrasound scanners can either provide full quantitative Doppler information on a limited sample volume (spectral Doppler), or averaged Doppler velocity and/or power estimation on a large region of interest (Doppler flow imaging). In this work, we investigate a different strategy for acquiring Doppler information that can overcome the limitations of the existing Doppler modes by significantly reducing the required acquisition time. This technique is called ultrafast compound Doppler imaging and is based on the following concept: instead of successively insonifying the medium with focused beams, several tilted plane waves are sent into the medium and the backscattered signals are coherently summed to produce high-resolution ultrasound images. We demonstrate that this strategy allows reduction of the acquisition time by a factor of up to of 16 while keeping the same Doppler performance. Depending on the application, different directions to increase performance of Doppler analysis are proposed and the improvement is quantified: the ultrafast compound Doppler method allows faster acquisition frame rates for high-velocity flow imaging, or very high sensitivity for low-flow applications. Full quantitative Doppler flow analysis can be performed on a large region of interest, leading to much more information and improved functionality for the physician. By leveraging the recent emergence of ultrafast parallel beamforming systems, this paper demonstrates that breakthrough performances in flow analysis can be reached using this concept of ultrafast compound Doppler.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Self-citationCoherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Self-citationBreast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., Namekawa, K., Koyano, A., & Omoto, R. (1985) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1985.31615 · Cited by 1,255
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., & Namekawa, K. (1985) · IEEE 1985 Ultrasonics Symposium · doi:10.1109/ultsym.1985.198654 · Cited by 573
Loupas, T., Powers, J. T., & Gill, R. W. (1995) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.393110 · Cited by 560
Self-citationBreast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S. (2010) · Radiology · doi:10.1148/radiol.10090385 · Cited by 519
Self-citationFung, Y. C. (1997) · Springer eBooks · doi:10.1007/978-1-4757-2696-1 · Cited by 466
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Sebag, F., Vaillant-Lombard, J., Berbis, J., Griset, V., Henry, J. F., Petit, P., & Oliver, C. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-0766 · Cited by 424
Liver fibrosis: non‐invasive assessment with MR elastography
Huwart, L., Peeters, F., Sinkus, R., Annet, L., Salameh, N., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1030 · Cited by 417
Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography
Tanter, M., Bercoff, J., Sandrin, L., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1041078 · Cited by 414
Self-citationShattuck, D. P., Weinshenker, M. D., Smith, S. W., & von Ramm, O. T. (1984) · The Journal of the Acoustical Society of America · doi:10.1121/1.390734 · Cited by 395
Bonnefous, O. (1986) · Ultrasonic Imaging · doi:10.1016/0161-7346(86)90001-5 · Cited by 343
Doppler Ultrasound: Physics, Instrumentation and Clinical Applications
Ritenour, E. R. (1990) · Radiology · doi:10.1148/radiology.177.2.346 · Cited by 289
ULA-OP: an advanced open platform for ultrasound research
Tortoli, P., Bassi, L., Boni, E., Dallai, A., Guidi, F., & Ricci, S. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1303 · Cited by 273
INITIAL EXPERIENCES WITH REAL-TIME ELASTOGRAPHY GUIDED BIOPSIES OF THE PROSTATE
KÖNIG, K., SCHEIPERS, U., PESAVENTO, A., LORENZ, A., ERMERT, H., & SENGE, T. (2005) · Journal of Urology · doi:10.1097/01.ju.0000162043.72294.4a · Cited by 262
2D and 3D high frame rate imaging with limited diffraction beams
Lu, J.-Y. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.655200 · Cited by 258
Udesen, J., Gran, F., Hansen, K., Jensen, J. A., Thomsen, C., & Nielsen, M. B. (2008) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.858 · Cited by 254
Shinohara, M., Sabra, K., Gennisson, J., Fink, M., & Tanter, M. (2010) · Muscle & Nerve · doi:10.1002/mus.21723 · Cited by 236
Self-citationFrey, H. (2003) · Der Radiologe · doi:10.1007/s00117-003-0943-2 · Cited by 204
Sonoelastic determination of human skeletal muscle elasticity
Levinson, S. F., Shinagawa, M., & Sato, T. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00173-2 · Cited by 203
Talwalkar, J. A., Yin, M., Venkatesh, S., Rossman, P. J., Grimm, R. C., Manduca, A., Romano, A., Kamath, P. S., & Ehman, R. L. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.07.3504 · Cited by 198
Miyagawa, T., Tsutsumi, M., Matsumura, T., et al. (2009) · Japanese Journal of Clinical Oncology · doi:10.1093/jjco/hyp026 · Cited by 123
Tortoli, P., Michelassi, V., Bambi, G., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00705-6 · Cited by 65
MR Elastography: Spleen Stiffness Measurements in Healthy Volunteers—Preliminary Experience
Mannelli, L., Godfrey, E. M., Joubert, I., Patterson, A. J., Graves, M. J., Gallagher, F. A., & Lomas, D. J. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3390 · Cited by 54
Elasticity Imaging Using Conventional and High-Frame Rate Ultrasound Imaging: Experimental Study
Park, S., Aglyamov, S. R., & Emelianov, S. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.529 · Cited by 39
Multigate Doppler Measurements of Ultrasonic Attenuation and Blood Hematocrit in Human Arteries
Secomski, W., Nowicki, A., Tortoli, P., & Olszewski, R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.08.009 · Cited by 8
Cited by
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Self-citationUltrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Self-citationDemene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Self-citationFunctional ultrasound imaging of the brain
Macé, E., Montaldo, G., Cohen, I., Baulac, M., Fink, M., & Tanter, M. (2011) · Nature Methods · doi:10.1038/nmeth.1641 · Cited by 751
Self-citationSuper-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Self-citation
Metadata
- Authors
- Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 2011-01
- Volume
- 58
- Issue
- 1
- Pages
- 134-147
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2108750254
- Cited by
- 510
- References
- 29
- FWCI
- 14.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.