Routine use of continuous glucose monitoring in 10 501 people with diabetes mellitus
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Aims: To analyse blood glucose control according to continuous glucose monitoring use in data from the CareLink™ database, and to identify factors associated with continuation of sensor use during sensor‐augmented pump therapy. Methods: The analysis used data from 10 501 people with Type 1 and 2 diabetes mellitus, of whom 7916 (61.7%) had used glucose sensors for ≥ 15 days during any 6‐month period over a 2‐year observation period. Data were analysed according to the extent of sensor use ( < 25%, 25–49%, 50–74% and ≥ 75% of the time). Time to discontinuation of sensor use was also analysed in new users of glucose sensors. Results: Compared with patients in the lowest sensor usage group and non‐users, the highest glucose sensor usage group had significantly (P < 0.0001) lower mean blood glucose and blood glucose sd, were more likely to achieve a mean blood glucose concentration < 8.6 mmol/l, (odds ratio 1.5, 95% CI 1.3–1.7; P < 0.0001), and had 50% fewer hypoglycaemic (blood glucose concentration < 2.8 mmol/l) episodes. Among new users, sensor use during the first month of therapy was an important predictor of subsequent discontinuation. Lack of full reimbursement was also significantly associated with early discontinuation, whereas measures of glycaemic control were predictive of discontinuation during long‐term treatment. Conclusions: The use of continuous glucose monitoring was significantly associated with reductions in hypoglycaemia and improved metabolic control during insulin pump therapy. Sensor use during the first month was strongly associated with long‐term adherence; patient education and training may be helpful in achieving this.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Donnelly, L. A., Morris, A. D., Frier, B. M., Ellis, J. D., Donnan, P. T., Durrant, R., Band, M. M., Reekie, G., & Leese, G. P. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01501.x · Cited by 511
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Self-citationYeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Ly, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Sensor-Augmented Pump Therapy for A1C Reduction (STAR 3) Study
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Perkins, B. A., Welsh, J. B., Willi, S. M., et al. (2011) · Diabetes Care · doi:10.2337/dc11-1248 · Cited by 118
Cited by
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Fonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
“In T1D, only near-daily use of personal CGM has been shown to be of benefit (5-9,14,66).”
BackgroundCharleer, S., Mathieu, C., Nobels, F., De Block, C., Radermecker, R. P., Hermans, M. P., Taes, Y., Vercammen, C., T'Sjoen, G., Crenier, L., et al. (2018) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-02498 · Cited by 196
Lawton, J., Blackburn, M., Allen, J., Campbell, F., Elleri, D., Leelarathna, L., Rankin, D., Tauschmann, M., Thabit, H., & Hovorka, R. (2018) · BMC Endocrine Disorders · doi:10.1186/s12902-018-0239-1 · Cited by 174
“Indeed, in keeping with observations and recommendations made by others [2, 11, 24] our findings point to a need for psycho-education and training amongst those using CGM to make optimal use of this technology.”
Result
Metadata
- Authors
- Battelino, T., Liabat, S., Veeze, H. J., Castañeda, J., Arrieta, A., & Cohen, O.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2015-07-14
- Volume
- 32
- Issue
- 12
- Pages
- 1568-1574
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2104768765
- Cited by
- 57
- References
- 11
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.