A quantitative review and meta‐analysis of performance of non‐standard laryngoscopes and rigid fibreoptic intubation aids
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Summary: This quantitative review summarises studies of rigid fibreoptic laryngoscopy systems. In 6622 ‘normal’ patients only the Bonfils and CTrach had homogenous data and first time intubation success rates above 90%. In 1110 patients predicted or known to be difficult to intubate only the Bonfils, CTrach and Glidescope had homogenous data and first‐time success rates above 90%. In comparative studies with the Macintosh‐3 blade, no device had homogenous data in more than one study. Many devices had higher summed performances, but due to data heterogeneity, interpretation is very difficult, if worthwhile at all. The currently available data do not provide strong evidence that these devices should supersede standard direct laryngoscopy for routine or difficult intubation. Further research needs to be of high quality, studying relevant patients to create such evidence. Multicentre collaborations are likely to be needed studying known difficult patients or creating databases reporting the success/failure rate of these devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
A clinical sign to predict difficult tracheal intubation; a prospective study
Mallampati, S. R., Gatt, S. P., Gugino, L. D., Desai, S. P., Waraksa, B., Freiberger, D., & Liu, P. L. (1985) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03011357 · Cited by 2,450
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
Adverse Respiratory Events in Anesthesia: A Closed Claims Analysis
Caplan, R. A., Posner, K. L., Ward, R. J., & Cheney, F. W. (1990) · Anesthesiology · doi:10.1097/00000542-199005000-00010 · Cited by 1,060
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
PREDICTING DIFFICULT INTUBATION
WILSON, M. E., SPIEGELHALTER, D., ROBERTSON, J. A., & LESSER, P. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.2.211 · Cited by 875
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703
The airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
Early clinical experience with a new videolaryngoscope (GlideScope®) in 728 patients
Cooper, R. M., Pacey, J. A., Bishop, M. J., & McCluskey, S. A. (2005) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03027728 · Cited by 562
The GlideScope® Video Laryngoscope: randomized clinical trial in 200 patients
Sun, D. A., Warriner, C. B., Parsons, D. G., Klein, R., Umedaly, H. S., & Moult, M. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei041 · Cited by 359
Airway Injury during Anesthesia: A Closed Claims Analysis
Domino, K. B., Posner, K. L., Caplan, R. A., & Cheney, F. W. (1999) · Anesthesiology · doi:10.1097/00000542-199912000-00023 · Cited by 357
Predicting difficult intubation
Frerk, C. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09909.x · Cited by 299
A new practical classification of laryngeal view
Cook, T. M. (2000) · Anaesthesia · doi:10.1046/j.1365-2044.2000.01270.x · Cited by 252
Self-citationBellhouse, C. P., & Doré, C. J. (1988) · Anaesthesia and Intensive Care · doi:10.1177/0310057x8801600315 · Cited by 212
Comparison of direct and video-assisted views of the larynx during routine intubation
Kaplan, M. B., Hagberg, C. A., Ward, D. S., Brambrink, A., Chhibber, A. K., Heidegger, T., Lozada, L., Ovassapian, A., Parsons, D., Ramsay, J., et al. (2006) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2006.01.002 · Cited by 203
Assessment of laryngeal view: Percentage of glottic opening scorevs Cormack and Lehane grading
Ochroch, E. A., Hollander, J. E., Kush, S., Shofer, F. S., & Levitan, R. M. (1999) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03013137 · Cited by 198
Risk Factors Assessment of the Difficult Airway: An Italian Survey of 1956 Patients
Cattano, D., Panicucci, E., Paolicchi, A., Forfori, F., Giunta, F., & Hagberg, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000136772.38754.01 · Cited by 159
Agrò, F. E., Barzoi, G., & Montecchia, F. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg560 · Cited by 153
The use of the GlideScope ® for tracheal intubation in patients with ankylosing spondylitis
Lai, H. Y., Chen, I. H., Chen, A., Hwang, F. Y., & Lee, Y. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael133 · Cited by 146
Watts, A. D. J., Gelb, A. W., Bach, D. B., & Pelz, D. M. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00012 · Cited by 143
Jackson, K., & Cook, T. M. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.04983.x · Cited by 142
Self-citationCervical Spine Movement during Laryngoscopy with the Bullard, Macintosh, and Miller Laryngoscopes
Hastings, R. H., Vigil, A. C., Hanna, R., Yang, B.-Y., & Sartoris, D. J. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00007 · Cited by 141
Lim, Y., & Yeo, S. W. (2005) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0503300215 · Cited by 113
Jordan, G., Silsby, J., Bayley, G., Cook, T. M., & Difficult Airway Society (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05069.x · Cited by 102
Self-citationBein, B., Worthmann, F., Scholz, J., Brinkmann, F., Tonner, P. H., Steinfath, M., & Dörges, V. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03778.x · Cited by 100
Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy*
Bein, B., Yan, M., Tonner, P. H., Scholz, J., Steinfath, M., & Dörges, V. (2004) · Anaesthesia · doi:10.1111/j.1365-2044.2004.03967.x · Cited by 94
Novel Airway Devices: Spoilt for Choice?
Cook, T. M. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03047.x · Cited by 92
Self-citationRudolph, C., Schneider, J. P., Wallenborn, J., & Schaffranietz, L. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04224.x · Cited by 88
Arino, J. J., Velasco, J. M., Gasco, C., & López‐Timoneda, F. (2003) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03021064 · Cited by 86
Smith, C. E., Pinchak, A. B., Sidhu, T. S., Radesic, B. P., Pinchak, A. C., & Hagen, J. F. (1999) · Anesthesiology · doi:10.1097/00000542-199911000-00015 · Cited by 75
Wahlen, B. M., & Gercek, E. (2004) · European Journal of Anaesthesiology · doi:10.1097/00003643-200411000-00013 · Cited by 66
Cooper, S. D., Benumof, J. L., & Ozaki, G. T. (1994) · Anesthesia & Analgesia · doi:10.1213/00000539-199411000-00025 · Cited by 66
Management of unexpected difficult airway at a teaching institution over a 7-year period
Connelly, N. R., Ghandour, K., Robbins, L. D., Dunn, S., & Gibson, C. (2006) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2005.08.011 · Cited by 61
Tracheal intubation using a Bullard laryngoscope for patients with a simulated difficult airway
MacQuarrie, K., Hung, O. R., & Law, J. A. (1999) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03013911 · Cited by 59
Does a new videolaryngoscope (glidescope) provide better glottic exposure?
Hsiao, W.-T., Lin, Y.-H., Wu, H.-S., & Chen, C.-L. (2005) · Acta anaesthesiologica Taiwanica · Cited by 35
The LMA CTrach TM in airway resuscitation: six case reports
Goldman, A. J., & Rosenblatt, W. H. (2006) · Anaesthesia · doi:10.1111/j.1365-2044.2006.04787.x · Cited by 28
Cited by
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
Self-citationAziz, M. F., Healy, D., Kheterpal, S., Fu, R. F., Dillman, D., & Brambrink, A. M. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182023eb7 · Cited by 395
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Self-citationGriesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-011-9620-5 · Cited by 363
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Metadata
- Authors
- Mihai, R., Blair, E., Kay, H., & Cook, T. M.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2008-06-10
- Volume
- 63
- Issue
- 7
- Pages
- 745-760
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1535762044
- Cited by
- 179
- References
- 37
- FWCI
- 24.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.