CoChat

Late‐night salivary cortisol for diagnosis of Cushing’s syndrome by liquid chromatography/tandem mass spectrometry assay

Erickson, Dana, Singh, Ravinder J., Sathananthan, Airani, Vella, Adrian, Bryant, Sandra C. · 2012 · Clinical Endocrinology
Cited by 51

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Summary: Background Late‐night salivary cortisol (LNSC) measurements have been increasingly used by physicians as an initial diagnostic test for evaluation of patients with clinical suspicion of Cushing’s syndrome (CS). Published studies include various numbers of cases, controls and importantly, various assay methods (vast majority various immunoassays), as well as various methods to generate cut‐points. Materials and Methods The retrospective study evaluated the diagnostic utility of LNSC measurements in 249 patients evaluated for possibility of CS because of various clinical conditions using liquid chromatography/tandem mass spectrometry method (LC‐MS/MS). CS was confirmed in 47 patients (18·9%) and excluded in 202 (81·1%) patients at the time of analysis. Results Late‐night salivary cortisol was abnormal or >2·8 nmol/l in 35 of 47 patients with CS; sensitivity of 74·5% and elevated in 20 of 202 patients who were found not to have CS; specificity 90·1%. Using receiver‐operator characteristic statistics for calculation of the most optimal sensitivity and specificity, the cut‐off based on this data was LNSC > 2·1 nmol/l with sensitivity of 83·0% and specificity of 84·2%. Conclusion Analysis of data at one referral institution showed somewhat limited sensitivity of LNSC for diagnosis of CS using current reference ranges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1365-2265.2011.04239.x

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Research works printed but not linked: 10

  1. 10.4158/EP09023OR · DOI · Paper page
  2. 10.1210/jc.84.3.878 · DOI
  3. Taylor R.L., 2002, Validation of a high‐throughput liquid chromatography‐tandem mass spectrometry method for urinary cortisol and cortisone, Clinical Chemistry, 48, 1511, 10.1093/clinchem/48.9.1511 · DOI · Paper page
  4. 10.1016/j.clinbiochem.2008.01.015 · DOI
  5. 10.1210/jc.2009-2458 · DOI · Paper page
  6. 10.1111/j.1365-2265.2008.03381.x · DOI · Paper page
  7. 10.1016/j.steroids.2009.02.009 · DOI
  8. 10.1016/j.steroids.2006.09.007 · DOI
  9. 10.1111/j.1365-2265.2005.02395.x · DOI · Paper page
  10. 10.1016/j.cca.2009.11.033 · DOI

Cited by

See all 51

Metadata

Authors
Erickson, D., Singh, R. J., Sathananthan, A., Vella, A., & Bryant, S. C.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
2012-03-07
Volume
76
Issue
4
Pages
467-472
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W1566700561
Cited by
51
References
12
FWCI
4.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Late‐night salivary cortisol for diagnosis of Cushing’s syndrome by liquid chromatography/tandem mass spectrometry assay. https://app.cochat.ai/papers/10.1111/j.1365-2265.2011.04239.x
The paper
Erickson, D., Singh, R. J., Sathananthan, A., Vella, A., & Bryant, S. C. (2012). Late‐night salivary cortisol for diagnosis of Cushing’s syndrome by liquid chromatography/tandem mass spectrometry assay. Clinical Endocrinology. https://doi.org/10.1111/j.1365-2265.2011.04239.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.