Depth‐dependent detection of microampere currents delivered to monkey V1
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Monkeys can detect electrical stimulation delivered to the striate cortex (area V1). We examined whether such stimulation is layer dependent. While remaining fixated on a spot of light, a rhesus monkey was required to detect a 100‐ms train of electrical stimulation delivered to a site within area V1. A monkey signaled the delivery of stimulation by depressing a lever after which he was rewarded with a drop of apple juice. Control trials were interleaved during which time no stimulation was delivered and the monkey was rewarded for not depressing the lever. Biphasic pulses were delivered at 200 Hz, and the current was typically at or < 30 μA using 0.2‐ms cathode‐first biphasic pulses. For some experiments, the pulse duration was varied from 0.05 to 0.7 ms and anode‐first pulses were used. The current threshold for detecting cathode‐first pulses 50% of the time was the lowest (< 10 μA) when stimulation was delivered to the deepest layers of V1 (between 1.0 and 2.5 mm below the cortical surface). Also, the shortest chronaxies (< 0.2 ms) and the shortest latencies (< 200 ms) for detecting the stimulation were observed at these depths. Finally, anode‐first pulses were most effective at evoking a detection response in superficial V1 and cathode‐first pulses were most effective at evoking a detection response in deep V1 (> 1.75 mm below the cortical surface). Accordingly, the deepest layers of V1 are the most sensitive for the induction of a detection response to electrical stimulation in monkeys.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferrier lecture. Functional architecture of macaque monkey visual cortex
Hubel, D. H., & Wiesel, T. N. (1977) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1977.0085 · Cited by 2,608 · cited 3×
“The striate cortex (or area V1) in primates is the first station of the retino-geniculo-striate pathway that receives an integrated visual signal from the two eyes before relaying the signal to higher cortical areas (Hubel & Wiesel, 1977).”
BackgroundResultNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170 · cited 4×
“Chronaxie estimates as a function of cortical depth To determine the excitability (or chronaxies) of the directly stimulated elements mediating the detection response, strength–duration functions were generated (Brindley & Lewin, 1968; Dobelle & ª The Authors (2009).”
BackgroundMethodResultInfluentialSchmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672 · cited 10×
“light varying in size to up to roughly 2 of visual angle (Dobelle & Mladejovsky, 1974; Schmidt et al., 1996).”
BackgroundMethodInfluentialAxons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
Visual sensations produced by intracortical microstimulation of the human occipital cortex
Bak, M., Girvin, J. P., Hambrecht, F. T., Kufta, C. V., Loeb, G. E., & Schmidt, E. M. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442682 · Cited by 299 · cited 12×
“more effective than anode-first pulses for stimulation of the deepest layers (Bak et al., 1990; Schmidt et al., 1996).”
BackgroundResultInfluentialDemonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195 · cited 1×
“…Journal of Neuroscience, 29, 1477–1489 prosthetic devices for the restoration of sensory and motor functions in disabled individuals (Otto et al., 2005; Leal-Campanario et al., 2006; Butovos & Schwarz, 2007; Fitzsimmons et al., 2007; Pezaris & Reid, 2007; Cogan, 2008; Schiller & Tehovnik, 2008).”
BackgroundMapping of functional organization in human visual cortex: Electrical cortical stimulation
Lee, H. W., Hong, S. B., Seo, D. W., Tae, W. S., & Hong, S. C. (2000) · Neurology · doi:10.1212/wnl.54.4.849 · Cited by 184
A model for intracortical visual prosthesis research
Troyk, P., Bak, M., Berg, J., Bradley, D., Cogan, S., Erickson, R., Kufta, C., McCreery, D., Schmidt, E., & Towle, V. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07308.x · Cited by 166 · cited 2×
“…results have lead to the notion that microstimulation of V1 in behaving monkeys could serve as a model for the implantation of a functional cortical visual prosthesis for blind patients (Troyk et al., 2003; Bartlett et al., 2005; Bradley et al., 2005; DeYoe et al., 2005; Tehovnik et al., 2005).”
Background
Cited by
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 308
Shape perception via a high-channel-count neuroprosthesis in monkey visual cortex
Chen, X., Wang, F., Fernandez, E., & Roelfsema, P. R. (2020) · Science · doi:10.1126/science.abd7435 · Cited by 250
Klink, P. C., Dagnino, B., Gariel-Mathis, M.-A., & Roelfsema, P. R. (2017) · Neuron · doi:10.1016/j.neuron.2017.05.033 · Cited by 135
“…previous results indicate that the precise positioning of the electrode arrayswithin this cortical depth range has relatively little influence on the qualitative effect of microstimulation (DeYoe et al., 2005; Murphey and Maunsell, 2007; Tehovnik and Slocum, 2009; Tehovnik et al., 2002).”
ResultImplantable microcoils for intracortical magnetic stimulation
Lee, S. W., Fallegger, F., Casse, B. D. F., & Fried, S. I. (2016) · Science Advances · doi:10.1126/sciadv.1600889 · Cited by 151
Metadata
- Authors
- Tehovnik, E. J., & Slocum, W. M.
- Venue
- European Journal of Neuroscience
- Publisher
- Wiley
- Published
- 2009-03-30
- Volume
- 29
- Issue
- 7
- Pages
- 1477-1489
- ISSN
- 0953-816X (ISSN-L)
- 1460-9568
- OpenAlex
- W2122995916
- Cited by
- 54
- References
- 12
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Depth‐dependent detection of microampere currents delivered to monkey V1. https://app.cochat.ai/papers/10.1111/j.1460-9568.2009.06695.x
- The paper
- Tehovnik, E. J., & Slocum, W. M. (2009). Depth‐dependent detection of microampere currents delivered to monkey V1. European Journal of Neuroscience. https://doi.org/10.1111/j.1460-9568.2009.06695.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.