CoChat

Depth‐dependent detection of microampere currents delivered to monkey V1

Open access
Tehovnik, Edward J., Slocum, Warren M. · 2009 · European Journal of Neuroscience
Cited by 54

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Monkeys can detect electrical stimulation delivered to the striate cortex (area V1). We examined whether such stimulation is layer dependent. While remaining fixated on a spot of light, a rhesus monkey was required to detect a 100‐ms train of electrical stimulation delivered to a site within area V1. A monkey signaled the delivery of stimulation by depressing a lever after which he was rewarded with a drop of apple juice. Control trials were interleaved during which time no stimulation was delivered and the monkey was rewarded for not depressing the lever. Biphasic pulses were delivered at 200 Hz, and the current was typically at or < 30 μA using 0.2‐ms cathode‐first biphasic pulses. For some experiments, the pulse duration was varied from 0.05 to 0.7 ms and anode‐first pulses were used. The current threshold for detecting cathode‐first pulses 50% of the time was the lowest (< 10 μA) when stimulation was delivered to the deepest layers of V1 (between 1.0 and 2.5 mm below the cortical surface). Also, the shortest chronaxies (< 0.2 ms) and the shortest latencies (< 200 ms) for detecting the stimulation were observed at these depths. Finally, anode‐first pulses were most effective at evoking a detection response in superficial V1 and cathode‐first pulses were most effective at evoking a detection response in deep V1 (> 1.75 mm below the cortical surface). Accordingly, the deepest layers of V1 are the most sensitive for the induction of a detection response to electrical stimulation in monkeys.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1460-9568.2009.06695.x

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 54

Metadata

Authors
Tehovnik, E. J., & Slocum, W. M.
Venue
European Journal of Neuroscience
Publisher
Wiley
Published
2009-03-30
Volume
29
Issue
7
Pages
1477-1489
ISSN
  • 0953-816X (ISSN-L)
  • 1460-9568
OpenAlex
W2122995916
Cited by
54
References
12
FWCI
1.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Depth‐dependent detection of microampere currents delivered to monkey V1. https://app.cochat.ai/papers/10.1111/j.1460-9568.2009.06695.x
The paper
Tehovnik, E. J., & Slocum, W. M. (2009). Depth‐dependent detection of microampere currents delivered to monkey V1. European Journal of Neuroscience. https://doi.org/10.1111/j.1460-9568.2009.06695.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.