CoChat

Assessment of Cardiovascular Autonomic Function: Age‐related Normal Ranges and Reproducibility of Spectral Analysis, Vector Analysis, and Standard Tests of Heart Rate Variation and Blood Pressure Responses

Ziegler, Dan, Laux, G., Dannehl, K., Spüler, M., Mühlen, H., Mayer, P., Gries, F.A. · 1992 · Diabetic Medicine
Cited by 375

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

To establish normal ranges for assessment of autonomic dysfunction, a battery of cardiovascular reflex tests was performed in 120 healthy subjects aged 15–67 years using a computer‐based technique. Tests of heart rate variation (HRV) included 8 measures at rest: coefficient of variation (CV), root mean squared successive difference (RMSSD), spectral analysis of HRV in the low frequency, mid frequency, and high frequency bands in the supine and standing postures; 5 measures during deep breathing: CV b, RMSSD b, Expiration‐Inspiration (E‐I) difference, E/I ratio, and mean circular resultant of vector analysis; Valsalva ratio, and max/min 30:15 ratio. In addition, the change in systolic and diastolic blood pressure in response to standing and the diastolic blood pressure response to sustained handgrip were determined. The results of all measures, the blood pressure tests excepted, declined significantly with increasing age (r = −0.16 to −0.59; p < 0.05). Moreover, RMSSD, RMSSD b, and E‐I difference decreased considerably with increasing heart rate (r = −0.37 to −0.52; p < 0.001). The longest and shortest R‐R intervals in response to standing were distributed within beats 21–39 and 6–24, respectively. All tests were independent of sex. Log transformation was used to define the age‐related lower limits of normal at the 2.3 centile for all tests of HRV, except for the E/I, Valsalva, and max/min 30:15 ratios. The results of these tests had to be analysed using a log(y‐1) transformation. The intra‐individual reproducibility determined on two consecutive days in 20 healthy subjects and 21 diabetic patients indicated that there were no major differences between the two groups regarding the day‐to‐day variation of test results, which was highest for the Valsalva ratio. We conclude that: (1) all indices of spectral and vector analyses of HRV are age‐dependent and have the advantage of being independent of heart rate; (2) RMSSD, E‐I difference, and the 30:15 ratio as it was used previously are not suitable for evaluation of autonomic dysfunction in diabetes; (3) log(y‐1) transformation is required to determine age‐dependent normal ranges and reproducibility for the three ratios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.1992.tb01754.x

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 375

Metadata

Authors
Ziegler, D., Laux, G., Dannehl, K., Spüler, M., Mühlen, H., Mayer, P., & Gries, F. A.
Venue
Diabetic Medicine
Publisher
Wiley
Published
1992-03
Volume
9
Issue
2
Pages
166-175
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W1966124808
Cited by
375
References
42
FWCI
12.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.