Diabet. Med. 29, 272–277 (2012) Aim To evaluate self‐reported satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy among women with pregestational diabetes. Methods Fifty‐four women with Type 1 diabetes and 14 women with Type 2 diabetes were offered continuous glucose monitoring for 6 days at median 9 (range 6–14) gestational weeks and were asked to answer a semi‐structured questionnaire on patient satisfaction. Results Median HbA 1c was 49 (range 34–86) mmol/mol) [6.6 (5.3–10.0) %] and duration of diabetes was 12 (0.5–37) years. Continuous glucose monitoring was used for 6 (0.5–7) days, with 43 (65%) women using continuous glucose monitoring for at least 5 days. The women experienced 2.7 (0–12) alarms per 24 h, of which approximately one third was technical alarms and one third disturbed their sleep. Sixteen women (24%) reported discomfort with continuous glucose monitoring during daytime and twelve (18%) during sleep. Many women reported improved diabetes understanding (52%) and would recommend continuous glucose monitoring to others (83%). Twenty‐four patients (36%) had continuous glucose monitoring removed earlier than planned ( before the intended 6 days of initial monitoring). Ten women (15%) did not wish to use continuous glucose monitoring again in pregnancy. Main causes behind early removal of continuous glucose monitoring were self‐reported skin irritation, technical problems and continuous glucose monitoring inaccuracy. No differences were found in continuous glucose monitoring use, inconvenience or compliance with respect to diabetes type. Conclusions The majority of pregnant women with diabetes found real‐time continuous glucose monitoring useful and the intervention was equally tolerated regardless of diabetes type. Nevertheless, continuous glucose monitoring was frequently removed earlier than planned, primarily because of skin irritation, technical problems and inaccuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.2011.03426.x

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 51

Metadata

Authors
Secher, A. L., Madsen, A. B., Ringholm, L., Barfred, C., Stage, E., Andersen, H. U., Damm, P., & Mathiesen, E. R.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2012-01-11
Volume
29
Issue
2
Pages
272-277
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W1564239023
Cited by
51
References
11
FWCI
3.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patient satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy in women with diabetes. https://app.cochat.ai/papers/10.1111/j.1464-5491.2011.03426.x
The paper
Secher, A. L., Madsen, A. B., Ringholm, L., Barfred, C., Stage, E., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2012). Patient satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy in women with diabetes. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2011.03426.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.