Patient satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy in women with diabetes
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Diabet. Med. 29, 272–277 (2012) Aim To evaluate self‐reported satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy among women with pregestational diabetes. Methods Fifty‐four women with Type 1 diabetes and 14 women with Type 2 diabetes were offered continuous glucose monitoring for 6 days at median 9 (range 6–14) gestational weeks and were asked to answer a semi‐structured questionnaire on patient satisfaction. Results Median HbA 1c was 49 (range 34–86) mmol/mol) [6.6 (5.3–10.0) %] and duration of diabetes was 12 (0.5–37) years. Continuous glucose monitoring was used for 6 (0.5–7) days, with 43 (65%) women using continuous glucose monitoring for at least 5 days. The women experienced 2.7 (0–12) alarms per 24 h, of which approximately one third was technical alarms and one third disturbed their sleep. Sixteen women (24%) reported discomfort with continuous glucose monitoring during daytime and twelve (18%) during sleep. Many women reported improved diabetes understanding (52%) and would recommend continuous glucose monitoring to others (83%). Twenty‐four patients (36%) had continuous glucose monitoring removed earlier than planned ( before the intended 6 days of initial monitoring). Ten women (15%) did not wish to use continuous glucose monitoring again in pregnancy. Main causes behind early removal of continuous glucose monitoring were self‐reported skin irritation, technical problems and continuous glucose monitoring inaccuracy. No differences were found in continuous glucose monitoring use, inconvenience or compliance with respect to diabetes type. Conclusions The majority of pregnant women with diabetes found real‐time continuous glucose monitoring useful and the intervention was equally tolerated regardless of diabetes type. Nevertheless, continuous glucose monitoring was frequently removed earlier than planned, primarily because of skin irritation, technical problems and inaccuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358
HbA1c levels are significantly lower in early and late pregnancy
Nielsen, L. R., Ekbom, P., Damm, P., Glümer, C., Frandsen, M. M., Jensen, D. M., & Mathiesen, E. R. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1200 · Cited by 331
Self-citationEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Hypoglycemia in Pregnant Women With Type 1 Diabetes
Nielsen, L. R., Pedersen-Bjergaard, U., Thorsteinsson, B., Johansen, M., Damm, P., & Mathiesen, E. R. (2008) · Diabetes Care · doi:10.2337/dc07-1066 · Cited by 204
Self-citationChanges in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy
Murphy, H. R., Rayman, G., Duffield, K., Lewis, K. S., Kelly, S., Johal, B., Fowler, D., & Temple, R. C. (2007) · Diabetes Care · doi:10.2337/dc07-0500 · Cited by 138
Cited by
The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2013) · Diabetes Care · doi:10.2337/dc12-2360 · Cited by 214
“This survey demonstrated that real-time CGM inaccuracy compared with self-monitored plasma glucose values, technical challenges, and skin irritation limits compliance (25), which is in line with previous studies of nonpregnant (12,32–35) and pregnant (27) patients.”
BackgroundMethodResultInfluentialSelf-citationClinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168
Voormolen, D. N., DeVries, J. H., Sanson, R. M. E., Heringa, M. P., de Valk, H. W., Kok, M., van Loon, A. J., Hoogenberg, K., Bekedam, D. J., Brouwer, T. C. B., et al. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13310 · Cited by 151
Berg, A. K., Nørgaard, K., Thyssen, J. P., Zachariae, C., Hommel, E., Rytter, K., & Svensson, J. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0088 · Cited by 87
“32 Skin reactions are a major factor in the reduced use or discontinuation of CGM in both children and pregnant women, 33,34 and studies have shown that discontinuation rates are * 35%–42%.”
Metadata
- Authors
- Secher, A. L., Madsen, A. B., Ringholm, L., Barfred, C., Stage, E., Andersen, H. U., Damm, P., & Mathiesen, E. R.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2012-01-11
- Volume
- 29
- Issue
- 2
- Pages
- 272-277
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1564239023
- Cited by
- 51
- References
- 11
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy in women with diabetes. https://app.cochat.ai/papers/10.1111/j.1464-5491.2011.03426.x
- The paper
- Secher, A. L., Madsen, A. B., Ringholm, L., Barfred, C., Stage, E., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2012). Patient satisfaction and barriers to initiating real‐time continuous glucose monitoring in early pregnancy in women with diabetes. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2011.03426.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.