Activity‐dependent slowing of conduction differentiates functional subtypes of C fibres innervating human skin
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
1. The effects of impulse activity on conduction in cutaneous C fibres have been examined in 46 microneurographic recordings from 11 normal subjects and 11 diabetic patients with normal nerve conduction. A tungsten microelectrode was inserted into a cutaneous nerve, usually the superficial peroneal close to the ankle, and intraneural microstimulation was used to identify an area of skin innervated. Three minute trains of 0.25 ms stimuli at 1, 2 and 4 Hz were then delivered to the surface of the skin, separated by intervals of 6 min with stimulation at 0.25 Hz. Slowing and block of conduction were measured from the nerve responses for up to seven C units per stimulation sequence. 2. Three types of C unit were distinguished by their responses to repetitive stimulation: type 1 units slowed progressively during the 3 min trains; slowing of type 2 units reached a plateau within 1 min; while type 3 units hardly slowed at all. Data from normal and diabetic subjects did not differ and were pooled. After 3 min at 2 Hz, the percentage increases in latency were for type 1, 28.3 +/- 9.7 (n = 63 units, mean +/- s.d.); for type 2, 5.2 +/- 1.6 (n = 14); and for type 3, 0.8 +/- 0.5 (n = 5), with no overlap. After 3 min at 4 Hz, 58 % of type 1 units (but no type 2 or 3 units) blocked intermittently. Recovery of latency after stimulation was faster for type 2 than for type 1 units, but conduction velocities of the three types were similar. 3. Type 1 units were identified as nociceptors and 7 type 2 units were identified as 'cold' fibres, activated by non-noxious cold, with no overlap in modality. None of the units tested was activated by weak mechanical stimuli or reflex sympathetic activation. 4. Spike waveforms were averaged for 18 type 1, 10 type 2 and 6 type 3 units. All units had predominantly triphasic action potentials with a major negative peak, but those of type 3 units were on average both smaller and briefer than those of type 1 and type 2 units. 5. It is concluded that repetitive electrical stimulation reliably differentiates nociceptive from cold-specific C fibres innervating human hairy skin, as has previously been shown for the rat. Cold fibres can propagate impulses continuously at much higher rates than nociceptive fibres. The nature of the type 3 units is unclear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Queer Current and Pacemaker: The Hyperpolarization-Activated Cation Current in Neurons
Pape, H.-C. (1996) · Annual Review of Physiology · doi:10.1146/annurev.ph.58.030196.001503 · Cited by 1,151
Threshold tracking techniques in the study of human peripheral nerve
Bostock, H., Cikurel, K., & Burke, D. (1998) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199802)21:2<137::aid-mus1>3.0.co;2-c · Cited by 582 · cited 1×
“However, although K¤ conductances are well known to modulate axonal excitability (Bostock et al. 1998), there is, as yet, no evidence that they can cause sufficient hyperpolarization to block conduction.”
BackgroundSelf-citationActivity from skin mechanoreceptors recorded percutaneously in awake human subjects
Vallbo, Å. B., & Hagbarth, K.-E. (1968) · Experimental Neurology · doi:10.1016/0014-4886(68)90041-1 · Cited by 530 · cited 1×
“The general technique of microneurography has been described in detail by its pioneers (Vallbo & Hagbarth, 1968).”
MethodNovel classes of responsive and unresponsive C nociceptors in human skin
Schmidt, R., Schmelz, M., Forster, C., Ringkamp, M., Torebjork, E., & Handwerker, H. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00333.1995 · Cited by 504
Rang, H. P., & Ritchie, J. M. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008502 · Cited by 431
Function and distribution of three types of rectifying channel in rat spinal root myelinated axons.
Baker, M., Bostock, H., Grafe, P., & Martius, P. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016395 · Cited by 352 · cited 1×
“In A fibres the post-tetanic hyperpolarization is limited by caesium-sensitive inward rectification (Baker et al. 1987), due to an ion conductance (Ih), activated by hyperpolarization (Pape, 1996).”
BackgroundSelf-citationAfferent G Units Responding to Mechanical, Thermal and Chemical Stimuli in Human Non‐Glabrous Skin
Torebjörk, H. E. (1974) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1974.tb05755.x · Cited by 299 · cited 3×
“…fibres than in myelinated ones (Ritchie & Straub, 1957; Grafe et al. 1997), and have been used in microneurographic recordings from humans as a ‘marking’ technique for C fibres activated by natural stimuli (Hallin & Torebj ork, 1974; Torebj ork, 1974; Ochoa & Torebj ork, 1989; Schmelz et al. 1995).”
MethodInfluentialSensations evoked by intraneural microstimulation of C nociceptor fibres in human skin nerves.
Ochoa, J., & Torebjörk, E. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017737 · Cited by 299
Self-citationNordin, M. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018135 · Cited by 295
The hyperpolarization which follows activity in mammalian non‐medullated fibres
Ritchie, J. M., & Straub, R. W. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005744 · Cited by 270
Cited by
NeuPSIG guidelines on neuropathic pain assessment
Haanpää, M., Attal, N., Backonja, M., Baron, R., Bennett, M., Bouhassira, D., Cruccu, G., Hansson, P., Haythornthwaite, J. A., Iannetti, G. D., et al. (2011) · Pain · doi:10.1016/j.pain.2010.07.031 · Cited by 1,060
Self-citationWind-up of spinal cord neurones and pain sensation: much ado about something?
Herrero, J. F., Laird, J. M. A., & Lopez-Garcia, J. A. (2000) · Progress in Neurobiology · doi:10.1016/s0301-0082(99)00051-9 · Cited by 714
McGlone, F., & Reilly, D. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.08.004 · Cited by 472
Chemical Response Pattern of Different Classes of C-Nociceptors to Pruritogens and Algogens
Schmelz, M., Schmidt, R., Weidner, C., Hilliges, M., Torebjörk, H. E., & Handwerker, H. O. (2003) · Journal of Neurophysiology · doi:10.1152/jn.01139.2002 · Cited by 399
Weidner, C., Schmelz, M., Schmidt, R., Hansson, B., Handwerker, H. O., & Torebjörk, H. E. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-22-10184.1999 · Cited by 348
Peripheral mechanisms of cutaneous nociception
Meyer, R. A., Ringkamp, M., Campbell, J. N., & Raja, S. N. (2006) · Wall and Melzack's Textbook of Pain · doi:10.1016/b0-443-07287-6/50006-0 · Cited by 317
Schmelz, M. (2000) · Brain · doi:10.1093/brain/123.3.560 · Cited by 296
Hyperexcitable C nociceptors in fibromyalgia
Serra, J., Collado, A., Solà, R., Antonelli, F., Torres, X., Salgueiro, M., Quiles, C., & Bostock, H. (2014) · Annals of Neurology · doi:10.1002/ana.24065 · Cited by 295
“Responses were digitally filtered, and the largest peaks displayed as a latency profile or raster plot, in which dots represented stimulated action potentials, noise, or spontaneous activity, including sympathetic fibers (Fig 1).(11) Time-locked responses with conduction velocity (CV) in the C-fiber range (<2m/s) and…”
MethodSelf-citationHerzog, R. I., Cummins, T. R., & Waxman, S. G. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.3.1351 · Cited by 290
Separate Peripheral Pathways for Pruritus in Man
Namer, B., Carr, R., Johanek, L. M., Schmelz, M., Handwerker, H. O., & Ringkamp, M. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90482.2008 · Cited by 274
Serra, J., Bostock, H., Solà, R., Aleu, J., García, E., Cokic, B., Navarro, X., & Quiles, C. (2012) · Pain · doi:10.1016/j.pain.2011.08.015 · Cited by 216
Self-citationAbnormal Function of C-Fibers in Patients with Diabetic Neuropathy
Ørstavik, K., Namer, B., Schmidt, R., Schmelz, M., Hilliges, M., Weidner, C., Carr, R. W., Handwerker, H., Jørum, E., & Torebjörk, H. E. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.2659-06.2006 · Cited by 215
“Activity-dependent slowing of conduction velocity is a well known characteristic of unmyelinated nerve fibers and can be used for differentiating functional subtypes of C-fibers (Serra et al., 1999; Weidner et al., 1999).”
BackgroundMethodInfluentialPathological C-fibres in patients with a chronic painful condition
Orstavik, K. (2003) · Brain · doi:10.1093/brain/awg060 · Cited by 210
“Recording from afferent C-®bres in diabetic patients has not shown any signs of altered conductive or receptive properties (Serra et al., 1999).”
BackgroundSlowly conducting afferents activated by innocuous low temperature in human skin
Campero, M., Serra, J., Bostock, H., & Ochoa, J. L. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.t01-1-00855.x · Cited by 209
“We previously reported a number of spontaneously active fibres in microneurographic recordings from human cutaneous fascicles, which were sensitive to small temperature changes (Serra et al. 1999).”
BackgroundMethodResultInfluentialSelf-citationDefining the Functional Role of NaV1.7 in Human Nociception
McDermott, L. A., Weir, G. A., Themistocleous, A. C., Segerdahl, A. R., Blesneac, I., Baskozos, G., Clark, A. J., Millar, V., Peck, L. J., Ebner, D., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.01.047 · Cited by 206
“This frequency of sensory afferent types was significantly different to normative data from healthy patients (Serra et al., 1999; Campero et al., 2004), owing to the lack of type 1 fibers (p < 0.”
MethodResultSelf-citationWeintraub, M. I., Wolfe, G. I., Barohn, R. A., Cole, S. P., Parry, G. J., Hayat, G., Cohen, J. A., Page, J. C., Bromberg, M. B., & Schwartz, S. L. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00106-0 · Cited by 204
Bucher, D., & Goaillard, J.-M. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2011.06.001 · Cited by 186
“…some quantitative differences between motor and sensory fibers (e.g. Kiernan, 2004), C-fibers of different sensory modalities (Bostock et al., 2003; Campero et al., 2004; Obreja et al., 2010; Serra et al., 1999; Weidner et al., 2000), and peripheral versus optic nerve axons (Oozeer et al., 2006).”
BackgroundBaker, M. D., Chandra, S. Y., Ding, Y., Waxman, S. G., & Wood, J. N. (2003) · The Journal of Physiology · doi:10.1111/j.1469-7793.2003.00373.x · Cited by 183
“Transmission in small diameter axons may lead to activity-related reductions in conduction velocity, which can be explained by hyperpolarization, brought about by electrogenic Na pumping (Serra et al. 1999).”
BackgroundThermoTRP channels and cold sensing: what are they really up to?
Reid, G. (2005) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-005-1437-z · Cited by 180
“have been studied in some detail using microneurography [15, 80].”
MethodStudying human nociceptors: from fundamentals to clinic
Middleton, S. J., Barry, A. M., Comini, M., Li, Y., Ray, P. R., Shiers, S., Themistocleous, A. C., Uhelski, M. L., Yang, X., Dougherty, P. M., et al. (2021) · Brain · doi:10.1093/brain/awab048 · Cited by 173
Blair, N. T., & Bean, B. P. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-32-10338.2003 · Cited by 163
“Adaptation of firing frequency is often accompanied by a reduction in conduction velocity (Thalhammer et al., 1994; Gee et al., 1996; Serra et al., 1999), implying that intrinsic membrane excitability is depressed.”
Reduction of skin innervation is associated with a severe fibromyalgia phenotype
Evdokimov, D., Frank, J., Klitsch, A., Unterecker, S., Warrings, B., Serra, J., Papagianni, A., Saffer, N., Meyer zu Altenschildesche, C., Kampik, D., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25565 · Cited by 152
“25 to 2Hz.(29,30) Responsiveness to mechanical stimuli was tested using a calibrated set of von Frey filaments”
BackgroundMethodInfluentialSelf-citationAn ultrafast system for signaling mechanical pain in human skin
Nagi, S. S., Marshall, A. G., Makdani, A., Jarocka, E., Liljencrantz, J., Ridderström, M., Shaikh, S., O’Neill, F., Saade, D., Donkervoort, S., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1297 · Cited by 140
“We also recorded from five C-fiber HTMRs (C-HTMRs), confirmed by the 2-Hz electrical stimulation protocol (24, 25).”
Method
Metadata
- Authors
- Serra, J., Campero, M., Ochoa, J., & Bostock, H.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1999-03
- Volume
- 515
- Issue
- 3
- Pages
- 799-811
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1984045322
- Cited by
- 218
- References
- 21
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.