Bedside assessment of fibrinogen level in postpartum haemorrhage by thrombelastometry
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Objectives To establish whether reagent‐supported thrombelastometry with the rotation thrombelastometry system (ROTEM®) point‐of‐care device correlated with fibrinogen level in postpartum haemorrhages. Design Prospective observational study. Population and setting Ninety‐one women at the third trimester of pregnancy: 37 with postpartum haemorrhage (study group) and 54 without abnormal bleeding (control group). Methods Standard laboratory test results were compared with those obtained at bedside from the ROTEM with the FIBTEM® test (54 tests in the control group and 51 in the study group). Main outcome measures Analysis of correlations between fibrinogen levels and FIBTEM test results: clotting time (CT), clot amplitude at 5 and 15 minutes (CA 5; CA 15) and maximal amplitude [maximum clot firmness (MCF)]. Results Median fibrinogen level was significantly lower in the haemorrhage group than in the control group (3.4 and 5.1 g/l, respectively, P < 0.0001). Median CT was higher in the haemorrhage group than in the control group (P = 0.05). CA 5, CA 15 and MCF were significantly lower in the haemorrhage group than in controls (P < 0.0001) and strongly correlated with fibrinogen levels in both groups (r = 0.84–0.87, P < 0.0001). A cut‐off value of CA 5 at 5 mm and CA 15 at 6 mm presented an excellent sensitivity (100% for both parameters) and a good specificity (respectively 85 and 88%) to detect fibrinogen levels <1.5 g/l in postpartum haemorrhage. Conclusions The early parameters obtained from the FIBTEM test correlated well with fibrinogen levels. ROTEM might be helpful in guiding fibrinogen transfusion during postpartum haemorrhage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The decrease of fibrinogen is an early predictor of the severity of postpartum hemorrhage
CHARBIT, B., MANDELBROT, L., SAMAIN, E., BARON, G., HADDAOUI, B., KEITA, H., SIBONY, O., MAHIEU‐CAPUTO, D., HURTAUD‐ROUX, M. F., HUISSE, M. G., et al. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02297.x · Cited by 762
Hemostatic Factors and Replacement of Major Blood Loss with Plasma-Poor Red Cell Concentrates
Hiippala, S. T., Myllyla, G. J., & Vahtera, E. M. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199508000-00026 · Cited by 703
Thrombelastography/thromboelastometry
LUDDINGTON, R. J. (2005) · Clinical and Laboratory Haematology · doi:10.1111/j.1365-2257.2005.00681.x · Cited by 655
Multi-centre investigation on reference ranges for ROTEM thromboelastometry
Lang, T., Bauters, A., Braun, S. L., Pötzsch, B., von Pape, K.-W., Kolde, H.-J., & Lakner, M. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000169225.31173.19 · Cited by 503
Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography
RUGERI, L., LEVRAT, A., DAVID, J. S., DELECROIX, E., FLOCCARD, B., GROS, A., ALLAOUCHICHE, B., & NEGRIER, C. (2007) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2007.02319.x · Cited by 491
Self-citationBose, P., Regan, F., & Paterson‐Brown, S. (2006) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2006.01018.x · Cited by 369
Salooja, N., & Perry, D. J. (2001) · Blood Coagulation and Fibrinolysis · doi:10.1097/00001721-200107000-00001 · Cited by 266
Coakley, M., Reddy, K., Mackie, I., & Mallett, S. (2006) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2006.01.016 · Cited by 232
SPALDING, G., HARTRUMPF, M., SIERIG, T., OESBERG, N., KIRSCHKE, C., & ALBES, J. (2007) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2007.02.022 · Cited by 209
Zhang, W., Alexander, S., Bouvier‐Colle, M., Macfarlane, A., & the MOMS‐B Group (2005) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2004.00303.x · Cited by 192
Coagulation assessment by rotation thrombelastometry in normal pregnancy
Carrabin, N., Benchaib, M., Fontaine, O., Levrat, A., Massignon, D., Touzet, S., Rudigoz, R.-C., Berland, M., & Huissoud, C. (2009) · Thrombosis and Haemostasis · doi:10.1160/th08-06-0386 · Cited by 166
Self-citationSuccessful reduction of massive postpartum haemorrhage by use of guidelines and staff education
Rizvi, F., Mackey, R., Barrett, T., McKenna, P. J., & Geary, M. P. (2004) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2004.00103.x · Cited by 141
Hémorragies du post-partum : recommandations du CNGOF pour la pratique clinique (décembre 2004)
Goffinet, F., Mercier, F. J., Teyssier, V., Pierre, F. H. F., Dreyfus, M., Mignon, A., Carbonne, B., & Lévy, G. (2005) · Gynécologie Obstétrique & Fertilité · doi:10.1016/j.gyobfe.2005.03.016 · Cited by 135
Estimation de la mortalité maternelle en France : une nouvelle méthode
Bouvier‐Colle, M., Deneux‐Tharaux, C., Szego, E., Couet, C., Michel, E., Varnoux, N., & Jougla, É. (2004) · Journal de gynécologie, obstétrique et biologie de la reproduction. Supplément/Journal de gynécologie obstétrique et biologie de la reproduction · doi:10.1016/s0368-2315(04)96550-7 · Cited by 36
Savry, C., Quinio, P., Lefèvre, F., & Schmitt, F. (2005) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2005.03.044 · Cited by 25
Cited by
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Fibrinogen as a therapeutic target for bleeding: a review of critical levels and replacement therapy
Levy, J. H., Welsby, I., & Goodnough, L. T. (2014) · Transfusion · doi:10.1111/trf.12431 · Cited by 331
FIBTEM provides early prediction of massive transfusion in trauma
Schöchl, H., Cotton, B., Inaba, K., Nienaber, U., Fischer, H., Voelckel, W., & Solomon, C. (2011) · Critical Care · doi:10.1186/cc10539 · Cited by 313
Whiting, P., Al, M., Westwood, M., Ramos, I. C., Ryder, S., Armstrong, N., Misso, K., Ross, J., Severens, J., & Kleijnen, J. (2015) · Health Technology Assessment · doi:10.3310/hta19580 · Cited by 310
Cortet, M., Deneux-Tharaux, C., Dupont, C., Colin, C., Rudigoz, R.-C., Bouvier-Colle, M.-H., & Huissoud, C. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes096 · Cited by 305
Self-citation
Metadata
- Authors
- Huissoud, C., Carrabin, N., Audibert, F., Levrat, A., Massignon, D., Berland, M., & Rudigoz, R.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 2009-06-10
- Volume
- 116
- Issue
- 8
- Pages
- 1097-1102
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W1537359966
- Cited by
- 230
- References
- 15
- FWCI
- 11.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.