CoChat

Bedside assessment of fibrinogen level in postpartum haemorrhage by thrombelastometry

Huissoud, C, Carrabin, N, Audibert, F, Levrat, A, Massignon, D, Berland, M, Rudigoz, R‐C · 2009 · BJOG: An International Journal of Obstetrics & Gynaecology
Cited by 230

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Objectives To establish whether reagent‐supported thrombelastometry with the rotation thrombelastometry system (ROTEM®) point‐of‐care device correlated with fibrinogen level in postpartum haemorrhages. Design Prospective observational study. Population and setting Ninety‐one women at the third trimester of pregnancy: 37 with postpartum haemorrhage (study group) and 54 without abnormal bleeding (control group). Methods Standard laboratory test results were compared with those obtained at bedside from the ROTEM with the FIBTEM® test (54 tests in the control group and 51 in the study group). Main outcome measures Analysis of correlations between fibrinogen levels and FIBTEM test results: clotting time (CT), clot amplitude at 5 and 15 minutes (CA 5; CA 15) and maximal amplitude [maximum clot firmness (MCF)]. Results Median fibrinogen level was significantly lower in the haemorrhage group than in the control group (3.4 and 5.1 g/l, respectively, P < 0.0001). Median CT was higher in the haemorrhage group than in the control group (P = 0.05). CA 5, CA 15 and MCF were significantly lower in the haemorrhage group than in controls (P < 0.0001) and strongly correlated with fibrinogen levels in both groups (r = 0.84–0.87, P < 0.0001). A cut‐off value of CA 5 at 5 mm and CA 15 at 6 mm presented an excellent sensitivity (100% for both parameters) and a good specificity (respectively 85 and 88%) to detect fibrinogen levels <1.5 g/l in postpartum haemorrhage. Conclusions The early parameters obtained from the FIBTEM test correlated well with fibrinogen levels. ROTEM might be helpful in guiding fibrinogen transfusion during postpartum haemorrhage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2009.02187.x

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

Metadata

Authors
Huissoud, C., Carrabin, N., Audibert, F., Levrat, A., Massignon, D., Berland, M., & Rudigoz, R.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2009-06-10
Volume
116
Issue
8
Pages
1097-1102
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W1537359966
Cited by
230
References
15
FWCI
11.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.