Clinical experience with a helical bipolar stimulating lead

TARVER, W. BRENT, GEORGE, RICHARD E., MASCHINO, STEVE E., HOLDER, LORI K., WERNICKE, J. F.·1992·Pacing and Clinical Electrophysiology

Abstract

Over 100 patients have been treated for partial epilepsy using a NeuroCybernetic Prosthesis System (NCP). The NCP System is comprised of an implantable pulse generator, an implantable bipolar stimulating lead, and an external communication system. The lead delivers electrical impulses from the NCP Generator to the vagus nerve, and includes a connector end that plugs into the generator, a silicone insulated lead body, and the helical electrode array that attaches to the nerve. The surgical implantation technique has a significant impact on lead reliability and performance. The lead electrode has performed well to date. Modifications to further improve reliability have been implemented. Clinical experience, case history examples, and voltage measurements are examined. The lead electrode is an important component of the overall system and plays a significant part in the success of vagus nerve stimulation therapy.

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.1992.tb02933.x

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F.
Affiliations
  • Webster Vienna Private University (AT)
  • Baylor College of Medicine (US)
Corresponding author
TARVER, W. BRENT
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
1992-10
Volume
15
Issue
10
Pages
1545-1556
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W1996475512
Cited by
46
References
14
Citations by year
2025: 1 · 2020: 4 · 2019: 2 · 2018: 3 · 2017: 1 · 2015: 2 · 2013: 1 · 2012: 3
FWCI
0.57
Type
journal article
Language
en
Open access
closed
Locations
  • Pacing and Clinical Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Neurology › Neurological disorders and treatments
Keywords
vagus nerve stimulation, focal epilepsy, implantable pulse generator, surgical implantation technique, voltage measurement
MeSH terms
Adolescent, Adult, Electrodes, Implanted, Electric Stimulation Therapy, Epilepsies, Partial, Equipment Design, Equipment Failure, Humans, Male, Vagus Nerve, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review