Intracranial EEG Substrates of Scalp EEG Interictal Spikes
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: To determine the area of cortical generators of scalp EEG interictal spikes, such as those in the temporal lobe epilepsy. Methods: We recorded simultaneously 26 channels of scalp EEG with subtemporal supplementary electrodes and 46 to 98 channels of intracranial EEG in 16 surgery candidates with temporal lobe epilepsy. Cerebral discharges with and without scalp EEG correlates were identified, and the area of cortical sources was estimated from the number of electrode contacts demonstrating concurrent depolarization. Results: We reviewed ∼600 interictal spikes recorded with intracranial EEG. Only a very few of these cortical spikes were associated with scalp recognizable potentials; 90% of cortical spikes with a source area of >10 cm 2 produced scalp EEG spikes, whereas only 10% of cortical spikes having <10 cm 2 of source area produced scalp potentials. Intracranial spikes with <6 cm 2 of area were never associated with scalp EEG spikes. Conclusions: Cerebral sources of scalp EEG spikes are larger than commonly thought. Synchronous or at least temporally overlapping activation of 10–20 cm 2 of gyral cortex is common. The attenuating property of the skull may actually serve a useful role in filtering out all but the most significant interictal discharges that can recruit substantial surrounding cortex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Cooper, R., Winter, A. L., Crow, H. J., & Walter, W. G. (1965) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(65)90088-x · Cited by 561
Linear and Nonlinear Current Density Reconstructions
Fuchs, M., Wagner, M., Köhler, T., & Wischmann, H.-A. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199905000-00006 · Cited by 436
Menendez, R. G. D. P., Andino, S. G., Lantz, G., Michel, C. M., & Landis, T. (2001) · Brain Topography · doi:10.1023/a:1012944913650 · Cited by 348
The localizing value of ictal EEG in focal epilepsy
Foldvary, N., Klem, G. H., Hammel, J. P., Bingaman, W. E., Najm, I., & Lüders, H. O. (2001) · Neurology · doi:10.1212/wnl.57.11.2022 · Cited by 274
Intracranial EEG Substrates of Scalp Ictal Patterns from Temporal Lobe Foci
Pacia, S. V., & Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01233.x · Cited by 253
Self-citationGloor, P. (1985) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198510000-00002 · Cited by 244
fMRI Activation in Continuous and Spike‐triggered EEG–fMRI Studies of Epileptic Spikes
Al‐Asmi, A., Bénar, C., Gross, D. W., Khani, Y. A., Andermann, F., Pike, B., Dubeau, F., & Gotman, J. (2003) · Epilepsia · doi:10.1046/j.1528-1157.2003.01003.x · Cited by 203
Defining Epileptogenic Foci: Past, Present, Future
Ebersole, J. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199711000-00003 · Cited by 173
Self-citation
Cited by
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Tatum, W. O. (2012) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31826b3ab7 · Cited by 273
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Seizures and Epilepsy in Alzheimer's Disease
Friedman, D., Honig, L. S., & Scarmeas, N. (2012) · CNS Neuroscience & Therapeutics · doi:10.1111/j.1755-5949.2011.00251.x · Cited by 229
“Over 10 cm2 of gyral surface must be involved in a discharge to generate a potential recorded at the scalp [50].”
BackgroundGrouiller, F., Thornton, R. C., Groening, K., Spinelli, L., Duncan, J. S., Schaller, K., Siniatchkin, M., Lemieux, L., Seeck, M., Michel, C. M., et al. (2011) · Brain · doi:10.1093/brain/awr156 · Cited by 199
“Only a fraction of cortical spikes recorded with intracranial electrodes can be identified on simultaneous scalp EEG recordings (Alarcon et al., 1994; Tao et al., 2005).”
BackgroundRecording and analysis techniques for high-frequency oscillations
Worrell, G. A., Jerbi, K., Kobayashi, K., Lina, J. M., Zelmann, R., & Le Van Quyen, M. (2012) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2012.02.006 · Cited by 196
“This is an unexpected, and surprising result given that previous work utilizing concurrent iEEG and scalp EEG report that approximately 7 cm 2 was required to generate a LFP spike detectable on the scalp (Tao et al., 2005; Fig.”
Synchrony in Normal and Focal Epileptic Brain: The Seizure Onset Zone is Functionally Disconnected
Warren, C. P., Hu, S., Stead, M., Brinkmann, B. H., Bower, M. R., & Worrell, G. A. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00368.2010 · Cited by 185
“These layers serve to distribute signal in such a way that 7 cm2 of coordinated cortical activity is required to produce a clear deflection detectable on the scalp (Tao et al. 2005).”
BackgroundHigh-frequency Oscillations and Other Electrophysiological Biomarkers of Epilepsy: Clinical Studies
Worrell, G., & Gotman, J. (2011) · Biomarkers in Medicine · doi:10.2217/bmm.11.74 · Cited by 181
Association of epileptiform abnormalities and seizures in Alzheimer disease.
Lam, A. D., Sarkis, R. A., Pellerin, K. R., Jing, J., Dworetzky, B. A., Hoch, D. B., Jacobs, C. S., Lee, J. W., Weisholtz, D. S., Zepeda, R., et al. (2020) · Neurology · doi:10.1212/wnl.0000000000010612 · Cited by 172
How to record high‐frequency oscillations in epilepsy: A practical guideline
Zijlmans, M., Worrell, G. A., Dümpelmann, M., Stieglitz, T., Barborica, A., Heers, M., Ikeda, A., Usui, N., & Le Van Quyen, M. (2017) · Epilepsia · doi:10.1111/epi.13814 · Cited by 165
Microphysiology of Epileptiform Activity in Human Neocortex
Schevon, C. A., Ng, S. K., Cappell, J., Goodman, R. R., McKhann, G., Waziri, A., Branner, A., Sosunov, A., Schroeder, C. E., & Emerson, R. G. (2008) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31818e8010 · Cited by 162
“, 2004) afford higher spatial resolution than scalp EEG (Pacia and Ebersole, 1997; Tao et al., 2005), the electrodes used, typically 3 to 5 mm in diameter, effectively sum the electrical potentials generated in large regions of underlying cortex and so cannot register spatial signal patterns at a submillimeter scale.”
Effect of EEG electrode number on epileptic source localization in pediatric patients
Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.038 · Cited by 149
Pitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Electrocorticography and functional mapping
(2019) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-64032-1.00020-5 · Cited by 28
Metadata
- Authors
- Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2005-04-27
- Volume
- 46
- Issue
- 5
- Pages
- 669-676
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2097542981
- Cited by
- 424
- References
- 18
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.