The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Remote Monitoring of Implantable Cardioverter Defibrillators: A Prospective Analysis
Abstract
A prospective study evaluating the functionality and ease of use of the Medtronic CareLink ® Network, “CareLink,” was conducted at ten investigational sites. This internet‐based remote monitoring service allows clinicians to remotely manage their patients' implantable cardioverter defibrillators (ICDs) and chronic diseases. The network is comprised of a patient monitor, a secure server, and clinician and patient websites. Under clinician direction, patients interrogated their ICDs at home, and transmitted data to secure servers via a standard telephone line. Comprehensive device data and a 10‐second presenting rhythm electrogram were captured by the monitor and available for access and review on the clinician website. The information could also be printed using a standard desktop computer with internet access. During this study, patients were asked to transmit device data twice, at least 7 days apart, as scheduled by the clinic. Monitor functionality was assessed, and ease of using the system components was evaluated via questionnaires completed by patients and clinicians following each data transmission and review. Fifty‐nine patients (64 ± 14 years, range 22‐85 years) completed 119 transmissions with only 14 calls to the study support center. Clinician review of data transmissions revealed several clinically significant findings, including silent AF discovery, assessment of antiarrhythmic drug efficacy in a previously diagnosed AF patient, previously unobserved atrial undersensing, and ventricular tachycardia. ICD patients found the monitor easy to use. Clinicians were pleased with the performance of the network and the quality of the web‐accessed data, and found it comparable to an in‐office device interrogation. CareLink is a practical tool for routine device management and may allow timely identification of clinically important issues. (PACE 2004; 27[Pt. I]:757–763)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A total of 56% (5/9) of the studies [22,28,42,78,91] demonstrated a benefit of telemonitoring on patient satisfaction when compared with a comparator”
From Interactive Remote Patient Monitoring Devices for Managing Chronic Health Conditions: Systematic Review and Meta-analysis (2022) · cites this paper as [91]
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,273
Self-citationGregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 907
Self-citationClinical Cardiac Pacing and Defibrillation
(2001) · Journal of Intensive Care Medicine · doi:10.1046/j.1525-1489.2001.00053-2.x · Cited by 184
Winters, S. L., Packer, D. L., Marchlinski, F. E., Lazzara, R., Cannom, D. S., BREITHARDT, G. E., WILBER, D. A., Camm, A. J., & Ruskin, J. N. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00262.x · Cited by 68
Bernstein, A. D., IRWIN, M. E., Parsonnet, V., Wilkoff, B. L., BLACK, W. R., Buckingham, T. A., Maloney, J. D., Reynolds, D., Saksena, S. V., Singer, I., et al. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03738.x · Cited by 60
Cardiology workforce: there’s already a shortage, and it’s getting worse!
Fye, W. B. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01935-6 · Cited by 46
Research works printed but not linked: 5
- McGrory‐Usset ME, 2002, New Development in Cardiac Pacing and Electrophysiology, 81
- Dressing TJ, 2002, Transtelephonic ICD Follow‐up is Better: More Comprehensive, Less Intrusive and More Desirable, PACE, 25, 219
- Igidbashian D, 2002, Benefit of permanent pacemaker follow‐up with home monitoring, PACE, 25, 47
- Stellbrink C, 2002, Home monitoring for pacemaker therapy: Intermediate results of first european multicenter study, PACE, 25, 655
- Owen R, 2003, Pacer/arrhythmia clinic improves patient satisfaction, EP Lab Digest, 3, 18
Cited by
Sorted by citations
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Self-citationACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,772
Self-citationEpstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276ce9b · Cited by 1,496
Self-citationInappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zaręba, W., Cannom, D. S., McNitt, S. A., Rosero, S. Z., Wang, P. J., Schuger, C. D., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 810
Tracy, C. M., Epstein, A. E., Darbar, D., Dimarco, J., Dunbar, S. B., Estes, N. A. M., Ferguson, T. B., Hammill, S. C., Karasik, P., Link, M. S., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.007 · Cited by 748
Self-citationVarma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
Epstein, A. E., Dimarco, J., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.014 · Cited by 550
Self-citationSlotwiner, D. J., Varma, N., Akar, J. G., Annas, G. J., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 533
Self-citationThe CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Self-citationStellios, I., Kotzanikolaou, P., Psarakis, M., Alcaraz, C., & López, J. (2018) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2855563 · Cited by 457
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364
Self-citationLandolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Varma, N., Piccini, J. P., Snell, J. D., Fischer, A., Dalal, N., & Mittal, S. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.033 · Cited by 232
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Europace · doi:10.1093/europace/eun122 · Cited by 231
Self-citationLazarus, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00595.x · Cited by 227
Clinical Benefits of Remote Versus Transtelephonic Monitoring of Implanted Pacemakers
Crossley, G. H., Chen, J., Choucair, W., Cohen, T. J., Gohn, D. C., Johnson, W. B., Kennedy, E. E., Mongeon, L. R., Serwer, G. A., Qiao, H., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.10.001 · Cited by 202
Self-citationRaatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
Burri, H., & Senouf, D. (2009) · EP Europace · doi:10.1093/europace/eup110 · Cited by 180
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P. E., Stone, P. H., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P. F., BREITHARDT, G. E., et al. (2012) · EP Europace · doi:10.1093/europace/eur303 · Cited by 178
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · EP Europace · doi:10.1093/europace/eum289 · Cited by 178
Robust Cyber–Physical Systems: Concept, models, and implementation
Hu, F., Lu, Y., Vasilakos, A. V., Hao, Q., Ma, R., Patil, Y. J., Zhang, T., Lu, J., Li, X., & Xiong, N. N. (2015) · Future Generation Computer Systems · doi:10.1016/j.future.2015.06.006 · Cited by 174
Ricci, R. P., Morichelli, L., & Santini, M. (2008) · EP Europace · doi:10.1093/europace/eun303 · Cited by 169
Automatic Remote Monitoring of Implantable Cardioverter-Defibrillator Lead and Generator Performance
Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. A. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.951962 · Cited by 164
Swerdlow, C. D., Gunderson, B. D., Ousdigian, K. T., Abeyratne, A., Stadler, R. W., Gillberg, J. M., Patel, A. S., & Ellenbogen, K. A. (2008) · Circulation · doi:10.1161/circulationaha.108.796136 · Cited by 141
Long-term patient acceptance of and satisfaction with implanted device remote monitoring
Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A. D. G., Porfili, A., Laudadio, M. T., Gargaro, A., & Santini, M. (2010) · EP Europace · doi:10.1093/europace/euq046 · Cited by 138
MARZEGALLI, M., LUNATI, M., LANDOLINA, M., PEREGO, G. B., RICCI, R. P., GUENZATI, G., SCHIRRU, M., BELVITO, C., BRAMBILLA, R., MASELLA, C., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01175.x · Cited by 134
Advanced ICD Troubleshooting: Part I
Swerdlow, C. D., & Friedman, P. A. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00275.x · Cited by 133
Hauser, R. G., Maisel, W. H., Friedman, P. A., Kallinen, L. M., Mugglin, A. S., Kumar, K., Hodge, D. O., Morrison, T. B., & Hayes, D. L. (2011) · Circulation · doi:10.1161/circulationaha.110.975219 · Cited by 121
Boriani, G., Costa, A. D., Ricci, R. P., Quesada, A., Favale, S., Iacopino, S., Romeo, F., Risi, A., Stefano, L. M. D. S., Navarro, X., et al. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2608 · Cited by 107
Telemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102
Swerdlow, C. D., Gunderson, B. D., Ousdigian, K. T., Abeyratne, A., Sachanandani, H., & Ellenbogen, K. A. (2010) · Circulation · doi:10.1161/circulationaha.110.962407 · Cited by 99
Jung, W., Rillig, A., Birkemeyer, R., Miljak, T., & Meyerfeldt, U. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9311-5 · Cited by 96
Kallinen, L. M., Hauser, R. G., Lee, K. W., Almquist, A. K., Katsiyiannis, W. T., Tang, C. Y., Melby, D. P., & Gornick, C. C. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.02.039 · Cited by 92
Automatic home monitoring of implantable cardioverter defibrillators
Nielsen, J. C., Kottkamp, H., Zabel, M., Aliot, E., Kreutzer, U., Bauer, A., Schuchert, A., Neuser, H., Schumacher, B., Schmidinger, H., et al. (2008) · EP Europace · doi:10.1093/europace/eun099 · Cited by 84
eHealth in cardiovascular medicine: A clinical update
Saner, H. E., & van der Velde, E. T. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316670256 · Cited by 79
Santini, M., Ricci, R. P., Lunati, M., Landolina, M., Perego, G. B., Marzegalli, M., Schirru, M., Belvito, C., Brambilla, R., Guenzati, G., et al. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9321-3 · Cited by 71
Simone, A. D., Leoni, L., Luzi, M., Amellone, C., Stabile, G., Rocca, V. L., Capucci, A., D’Onofrio, A., Ammendola, E., Accardi, F., et al. (2015) · EP Europace · doi:10.1093/europace/euu318 · Cited by 69
Leo, D. G., Buckley, B. J. R., Chowdhury, M., Harrison, S. L., Isanejad, M., Lip, G. Y. H., Wright, D. J., Lane, D. A., & the TAILOR investigators (2022) · Journal of Medical Internet Research · doi:10.2196/35508 · Cited by 62
Braunschweig, F., Ford, I., Conraads, V. M., Cowie, M., Jondeau, G., Kautzner, J., Lunati, M., Aguilera, R. M., Yu, C., Marijianowski, M. M. H., et al. (2008) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2008.06.016 · Cited by 60
Remote monitoring of cardiac implantable electronic devices and disease management
Varma, N., Braunschweig, F., Burri, H., Hindricks, G., Linz, D., Michowitz, Y., Ricci, R. P., & Nielsen, J. C. (2023) · EP Europace · doi:10.1093/europace/euad233 · Cited by 57
Varma, N. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.07.051 · Cited by 57
Yee, R., Verma, A., Beardsall, M., Fraser, J. A., Philippon, F., & Exner, D. V. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.11.036 · Cited by 54
Timmermans, I., Meine, M., Szendey, I., Aring, J., Roldán, J. R., van Erven, L., Kahlert, P., Zitron, E., Mabo, P., Denollet, J., et al. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13574 · Cited by 53
Boriani, G., Diemberger, I., Martignani, C., Biffi, M., Valzania, C., Bertini, M., Domenichini, G., Saporito, D., Ziacchi, M., & Branzi, A. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0355-5 · Cited by 53
Advanced ICD Troubleshooting: Part II
Swerdlow, C. D., & Friedman, P. A. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00300.x · Cited by 53
Remote Monitoring for Advisories: Automatic Early Detection of Silent Lead Failure
Varma, N. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02314.x · Cited by 52
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Varma, N., Pavri, B. B., Stambler, B. S., Michalski, J., & TRUST Investigators (2012) · EP Europace · doi:10.1093/europace/eus410 · Cited by 47
Remote monitoring of cardiac implantable electronic devices (CIED)
Zeitler, E. P., & Piccini, J. P. (2016) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2016.03.012 · Cited by 46
Contemporary Pacemaker and Defibrillator Device Therapy
Schoenfeld, M. H. (2007) · Circulation · doi:10.1161/circulationaha.106.618587 · Cited by 45
Self-citationRemote implantable cardioverter defibrillator monitoring in a Brugada syndrome population
Sacher, F., Probst, V., Bessouet, M., Wright, M. J., Maluski, A., Abbey, S., Bordachar, P., Deplagne, A., Ploux, S., Lande, G., et al. (2008) · EP Europace · doi:10.1093/europace/eup034 · Cited by 44
Lunati, M., Gasparini, M., Santini, M., Landolina, M., Perego, G. B., Pappone, C., Marzegalli, M., ARGIOLAS, C., Murthy, A., Valsecchi, S., et al. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00923.x · Cited by 41
Compliance with Remote Monitoring of ICDS/CRTDS in a Real‐World Population
Rosenfeld, L. E., Patel, A. S., Ajmani, V. B., Holbrook, R., & BRAND, T. A. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12358 · Cited by 40
Analysis of 57,148 Transmissions by Remote Monitoring of Implantable Cardioverter Defibrillators
Theuns, D. A. M. J., Rivero‐Ayerza, M., Knops, P., Res, J., & Jordaens, L. J. L. M. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02230.x · Cited by 40
Assessment of a remote monitoring system for implantable cardioverter defibrillators
Masella, C., Zanaboni, P., Stasi, F. D., Gilardi, S., Ponzi, P., & Valsecchi, S. (2008) · Journal of Telemedicine and Telecare · doi:10.1258/jtt.2008.080202 · Cited by 37
Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands
de Cock, C. C., Elders, J., van Hemel, N. M., van den Broek, K., van Erven, L., de Mol, B. A. J. M., Talmon, J. L., Theuns, D. A. M. J., & de Voogt, W. (2012) · Netherlands Heart Journal · doi:10.1007/s12471-011-0239-5 · Cited by 34
Marcus, G. M., CHAN, D. W., & Redberg, R. F. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02971.x · Cited by 34
Remote Active Monitoring in Patients With Heart Failure (RAPID-RF): Design and Rationale
Saxon, L. A., BOEHMER, J. P., Neuman, S., & Mullin, C. M. (2007) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2006.12.004 · Cited by 33
Sophisticated Remote Implantable Cardioverter‐Defibrillator Follow‐Up: A Status Report
Schoenfeld, M. H., & REYNOLDS, D. W. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.09554.x · Cited by 33
Self-citationVersteeg, H., Pedersen, S. S., Mastenbroek, M. H., Redekop, W. K., Schwab, J. O., Mabo, P., & Meine, M. (2014) · Netherlands Heart Journal · doi:10.1007/s12471-014-0587-z · Cited by 32
Chen, J., Wilkoff, B. L., Choucair, W. K., Cohen, T. J., Crossley, G. H., Johnson, W. B., Mongeon, L., Serwer, G. A., & Sherfesee, L. (2008) · Trials · doi:10.1186/1745-6215-9-18 · Cited by 30
Self-citationRuvo, E. D., Sciarra, L., Martino, A. M., Rebecchi, M., Iulianella, R. V., Sebastiani, F., Fagagnini, A., Borrelli, A., Scarà, A., Grieco, D., et al. (2015) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-015-0067-4 · Cited by 30
Transparent sharing of digital health data: A call to action
Slotwiner, D. J., Tarakji, K. G., Al‐Khatib, S. M., PASSMAN, R. S., Saxon, L. A., Peters, N. S., McCall, D., Turakhia, M. P., Schaeffer, J., Mendenhall, G. S., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.04.042 · Cited by 29
A Review on Remote Monitoring Technology Applied to Implantable Electronic Cardiovascular Devices
Costa, P. D., Rodrigues, P. P., Reis, A. H., & Costa‐Pereira, A. (2010) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2010.0082 · Cited by 28
The follow-up of cardiac devices: what to expect for the future?
Stellbrink, C., & Trappe, H. (2007) · European Heart Journal Supplements · doi:10.1093/eurheartj/sum071 · Cited by 27
Hauser, R. G., Mugglin, A. S., Friedman, P. A., Kramer, D. B., Kallinen, L. M., McGriff, D. M., & Hayes, D. L. (2012) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.111.962621 · Cited by 27
Impact of Remote Monitoring on Clinical Outcomes
Varma, N., & Ricci, R. P. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12829 · Cited by 26
López-Villegas, A., Catalán-Matamoros, D., Robles‐Musso, E., & Peiró, S. (2015) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/ggi.12612 · Cited by 26
Antepartum Fetal Monitoring through a Wearable System and a Mobile Application
Signorini, M. G., Lanzola, G., Torti, E., Fanelli, A., & Magenes, G. (2018) · Technologies · doi:10.3390/technologies6020044 · Cited by 24
Varma, N. (2013) · EP Europace · doi:10.1093/europace/eut116 · Cited by 23
Andò, K., Koyama, J., Abe, Y., Sato, T., Shoda, M., Soga, Y., Nobuyoshi, M., Honda, T., Nakao, K., Terata, K., et al. (2011) · International Heart Journal · doi:10.1536/ihj.52.39 · Cited by 20
Remotely monitored inactivity due to COVID-19 lockdowns
Fagih, A. R. A., Onazi, M. A., Basiri, S. A., Alkaf, F., Dagriri, K., Hebaishi, Y. A., Samargandy, S., & Shengeiti, L. A. (2020) · Saudi Medical Journal · doi:10.15537/smj.2020.11.25449 · Cited by 19
Osca, J., Tello, M. J. S., Navarro, J., Cano, Ó., Raso, R., Castro, J. E., Olagüe, J., & Salvador, A. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)72071-8 · Cited by 19
Ottenberg, A. L., Swetz, K. M., Mueller, L. A., Gerhardson, S., & Mueller, P. S. (2013) · Heart & Lung · doi:10.1016/j.hrtlng.2013.03.002 · Cited by 19
Remote detection of incessant slow VT with an ICD capable of home monitoring
SIAPLAOURAS, S. (2006) · EP Europace · doi:10.1093/europace/eul050 · Cited by 19
Device Features for Managing Patients with Heart Failure
Varma, N., & Wilkoff, B. L. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.005 · Cited by 18
Impact of COVID-19 Pandemic on Cardiac Electronic Device Management and Role of Remote Monitoring
Magnocavallo, M., Vetta, G., Bernardini, A., Piro, A., Mei, M. C., Iorio, M. D., Mariani, M. V., Rocca, D. G. D., Severino, P., Quaglione, R., et al. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.10.010 · Cited by 18
Characteristics of Sprint Fidelis lead failure.
Beukema, R. J., Misier, A. R. R., Delnoy, P. P. H. M., Smit, J. J. J., & Elvan, A. (2010) · PubMed Central · Cited by 18
Perings, C. A., Klein, G. G., Toft, E., Moro, C., Klug, D., Böcker, D., Trappe, H., & Korte, T. (2006) · EP Europace · doi:10.1093/europace/eul009 · Cited by 18
Cronin, E. M., & Varma, N. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.18 · Cited by 17
López-Villegas, A., Catalán-Matamoros, D., López‐Liria, R., Enebakk, T., Thunhaug, H., & Lappegård, K. T. (2018) · BMC Geriatrics · doi:10.1186/s12877-018-0911-3 · Cited by 17
Leppert, F., Siebermair, J., Wesemann, U., Martens, E., Sattler, S. M., Scholz, S. M., Veith, S., Greiner, W., Rassaf, T., Kääb, S., et al. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01667-0 · Cited by 17
Pron, G. E., Ieraci, L., & Kaulback, K. (2012) · Europe PMC (PubMed Central) · Cited by 17
Costa, P. D., Reis, A. H., & Rodrigues, P. P. (2013) · Telemedicine and e-Health · doi:10.1089/tmj.2012.0064 · Cited by 16
López-Villegas, A., Catalán-Matamoros, D., Robles‐Musso, E., & Peiró, S. (2015) · Revista Española de Salud Pública · doi:10.4321/s1135-57272015000200004 · Cited by 16
Osca, J., Tello, M. J. S., Navarro, J., Cano, Ó., Raso, R., Castro, J. E., Olagüe, J., & Salvador, A. (2009) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(09)72653-2 · Cited by 16
Timmermans, I., Meine, M., Zitron, E., Widdershoven, J. W. M. G., Kimman, G., Prévôt, S., Rauwolf, T., Anselme, F., Szendey, I., Roldán, J. R., et al. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13123 · Cited by 16
Usefulness of Remote Monitoring in Cardiac Implantable Device Follow-Up
Stoepel, C., Boland, J. L., Busca, R., Saal, G., & Oliveira, M. (2009) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2009.0068 · Cited by 16
Remote Monitoring of Patients With Implanted Cardiac Devices
Kusumoto, F. M., & Goldschlager, N. (2010) · Clinical Cardiology · doi:10.1002/clc.20688 · Cited by 16
Lim, P., Lee, A., Chua, K., Lim, E., Chong, D. W. S., Tan, B., Ho, K., Teo, W. S., & Ching, C. (2016) · Singapore Medical Journal · doi:10.11622/smedj.2016120 · Cited by 16
Marzegalli, M., Landolina, M., Lunati, M., Perego, G. B., Pappone, A., Guenzati, G., Campana, C., Frigerio, M., Parati, G., Curnis, A., et al. (2009) · Trials · doi:10.1186/1745-6215-10-42 · Cited by 16
Implantable medical devices as agents and part of multiagent systems
Drew, T., & Gini, M. L. (2006) · Adaptive Agents and Multi-Agents Systems · doi:10.1145/1160633.1160930 · Cited by 15
Gramegna, L., Tomasi, C., Gasparini, G. M., Scaboro, G., Zanon, F., Boaretto, G., Tomei, R., & Tomasi, L. (2011) · EP Europace · doi:10.1093/europace/eur334 · Cited by 14
Zoppo, F., Facchin, D., Molon, G., Zanotto, G., Catanzariti, D., Rossillo, A., Baccillieri, S., MENARD, C., COMISSO, J., Gentili, A., et al. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12474 · Cited by 14
Pacemaker Remote Monitoring in the Pediatric Population: Is It A Real Solution?
Leoni, L., Padalino, M. A., Biffanti, R., Ferretto, S., Vettor, G., Corrado, D., Stellin, G., Milanesi, O., & Iliceto, S. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12600 · Cited by 14
Work burden with remote monitoring of implantable cardioverter defibrillator
Papavasileiou, L. P., Forleo, G. B., Panattoni, G., Schirripa, V., Minni, V., Magliano, G., Bellos, K., Santini, L., & Romeo, F. (2012) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e328354e3e1 · Cited by 14
Ricci, R. P., Pignalberi, C., Magris, B., Aquilani, S., Altamura, V., Morichelli, L., Porfili, A., Quarta, L., Saputo, F. A., & Santini, M. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9612-y · Cited by 13
Remote Surveillance of Implantable Cardiac Devices
Orlov, M. V., Szombathy, T., CHAUDHRY, G. M., & Haffajee, C. I. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02412.x · Cited by 13
Ahmed, I., Patel, A. S., BALGAARD, T. J., & Rosenfeld, L. E. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12798 · Cited by 13
Mittal, S., Movsowitz, C., & Varma, N. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2014.01.001 · Cited by 12
Metadata
- Authors
- SCHOENFELD, M. H., COMPTON, S. J., MEAD, R. H., WEISS, D. N., SHERFESEE, L., ENGLUND, J., & MONGEON, L. R.
- Affiliations
- Yale University (US)
- Alaska Heart and Vascular Institute (US)
- Sequoia Hospital (US)
- Medtronic (United States) (US)
- Corresponding author
- SCHOENFELD, MARK H.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2004-05-25
- Volume
- 27
- Issue
- 6p1
- Pages
- 757-763
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2158824883
- Cited by
- 194
- References
- 11
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 6 · 2017: 4 · 2016: 6 · 2015: 10 · 2014: 7 · 2013: 17 · 2012: 17
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Pacing and Clinical Electrophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- implantable cardioverter-defibrillator, remote monitoring, atrial fibrillation detection, atrial undersensing, ventricular tachycardia, antiarrhythmic efficacy, ease of use
- MeSH terms
- Adult, Aged, Aged, 80 and over, Anti-Arrhythmia Agents, Atrial Fibrillation, Computer Communication Networks, Computer Systems, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Telemetry, Telephone, Death, Sudden, Cardiac, Defibrillators, Implantable, Tachycardia, Ventricular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review