Are Elderly Patients at Increased Risk of Complications Following Pacemaker Implantation? A Meta‐Analysis of Randomized Trials
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Patients over the age of 75 represent more than half the recipients of permanent pacemakers. It is not known if they have a different risk of complications than younger patients. Methods: Patient‐level data were pooled from the CTOPP, UKPACE, and Danish pacing trials. These three randomized trials of pacing mode systematically captured early and late complications following pacemaker insertion. Early postimplant complications included lead dislodgement or loss of capture, cardiac perforation, pneumothorax, hematoma, infection, and death. Lead fracture was considered a late complication. Results: A total of 4,814 patients were included in this analysis, with an average follow‐up of 5.1 years. The average age was 76 years and 43% were female. Any early complication occurred in 5.1% of patients ≥75 years of age compared to 3.4% of patients aged <75 years (P = 0.006). This was driven by an increased risk of pneumothorax (1.6% vs 0.8%, P = 0.07) and both atrial and ventricular lead dislodgement/loss of capture (2.0% vs 1.1%, P = 0.07). Early complications were higher in patients receiving atrial‐based pacemakers in both age groups (<75 years: 4.6% vs 2.4%; ≥75 years: 6.6% vs 3.7%); however, the relative risk was not influenced by age group. Older patients had a lower risk of lead fracture (3.6% vs 2.7%, P = 0.08). Conclusion: Elderly patients (≥75 years of age) are at increased risk of early postimplant complications but are at lower risk for lead fracture. PACE 2012; 35:131–134)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
The management of patients with carotid sinus syndrome: is pacing the answer?
Healey, J., Connolly, S. J., & Morillo, C. A. (2004) · Clinical Autonomic Research · doi:10.1007/s10286-004-1012-2 · Cited by 42
Self-citation
Research works printed but not linked: 19
- 10.1111/j.1540-8159.1994.tb03791.x · DOI · Paper page
- 10.1136/hrt.73.6.571 · DOI · Paper page
- 10.1510/icvts.2010.254813 · doi:10.1510/icvts.2010.254813
- 10.1016/S0003-4975(97)00615-2 · DOI · Paper page
- 10.1161/CIRCULATIONAHA.105.610303 · DOI · Paper page
- 10.1161/01.CIR.0000109490.72104.EE · DOI · Paper page
- 10.1016/S0140-6736(94)90347-6 · DOI · Paper page
- 10.1093/eurheartj/ehl438 · DOI · Paper page
- 10.1016/S0002-9149(96)90394-X · DOI
- Armaganijan L, 2011, Cardiothoracic Surgery in the Elderly, 654
- 10.1093/europace/eum019 · DOI · Paper page
- 10.1056/NEJM199804163381602 · DOI · Paper page
- 10.1111/j.1525-1594.1995.tb02454.x · DOI
- 10.1111/j.1540-8159.1995.tb04742.x · doi:10.1111/j.1540-8159.1995.tb04742.x
- 10.1097/00003246-199504000-00018 · doi:10.1097/00003246-199504000-00018
- 10.1111/j.1540-8159.1998.tb00071.x · doi:10.1111/j.1540-8159.1998.tb00071.x
- 10.1111/j.1540-8159.1996.tb03159.x · doi:10.1111/j.1540-8159.1996.tb03159.x
- 10.1016/j.hrthm.2005.06.011 · DOI · Paper page
- 10.1093/europace/eun363 · doi:10.1093/europace/eun363
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Self-citation2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citation
Metadata
- Authors
- ARMAGANIJAN, L. V., TOFF, W. D., NIELSEN, J. C., ANDERSEN, H. R., CONNOLLY, S. J., ELLENBOGEN, K. A., & HEALEY, J. S.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2011-10-31
- Volume
- 35
- Issue
- 2
- Pages
- 131-134
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1850764020
- Cited by
- 117
- References
- 2
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.