The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Patients Treated with Catheter Ablation for Atrial Fibrillation Have Long‐Term Rates of Death, Stroke, and Dementia Similar to Patients Without Atrial Fibrillation
Abstract
Outcomes in Patients With AF. Introduction: Atrial fibrillation (AF) adversely impacts mortality, stroke, heart failure, and dementia. AF ablation eliminates AF in most patients. We evaluated the long‐term impact of AF ablation on mortality, heart failure (HF), stroke, and dementia in a large system‐wide patient population. Methods: A total of 4,212 consecutive patients who underwent AF ablation were compared (1:4) to 16,848 age/gender matched controls with AF (no ablation) and 16,848 age/gender matched controls without AF. Patients were enrolled from the large ongoing prospective Intermountain AF study and were followed for at least 3 years. Results: Of the 37,908 patients, mean age 65.0 ± 13 years, 5,667 (14.9%) died, 1,296 (3.4%) had a stroke, and 1,096 (2.9%) were hospitalized for HF over >3 years of follow‐up. AF ablation patients were less likely to have diabetes, but were more likely to have hypertension, HF, and significant valvular heart disease. AF ablation patients had a lower risk of death and stroke in comparison to AF patients without ablation. Alzheimer's dementia occurred in 0.2% of the AF ablation patients compared to 0.9% of the AF no ablation patients and 0.5% of the no AF patients (P < 0.0001). Other forms of dementia were also reduced significantly in those treated with ablation. Compared to patients with no AF, AF ablation patients had similar long‐term rates of death, dementia, and stroke. Conclusions: AF ablation patients have a significantly lower risk of death, stroke, and dementia in comparison to AF patients without ablation. AF ablation may eliminate the increased risk of death and stroke associated with AF. (J Cardiovasc Electrophysiol, Vol. 22, pp. 839‐845, August 2011)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Miyasaka, Y., Barnes, M. E., Gersh, B. J., Cha, S. S., Bailey, K. R., Abhayaratna, W. P., Seward, J. B., & Tsang, T. S. M. (2006) · Circulation · doi:10.1161/circulationaha.105.595140 · Cited by 2,564
Van Gelder, I. C., Hagens, V. E., Bosker, H. A., Kingma, J. H., Kamp, O., Kingma, T., Said, S. A., Darmanata, J. I., Timmermans, A. J. M., Tijssen, J. G. P., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa021375 · Cited by 2,359
Rhythm control versus rate control for atrial fibrillation and heart failure
Roy, D., Talajic, M., Nattel, S., Wyse, D. G., Dorian, P., Lee, K. L., Bourassa, M. G., Arnold, J. M. O., Buxton, A. E., Camm, A. J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708789 · Cited by 1,585
Stewart, S., Hart, C. L., Hole, D. J., & McMurray, J. J. V. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01236-6 · Cited by 1,562
The AFFIRM Investigators (2004) · Circulation · doi:10.1161/01.cir.0000121736.16643.11 · Cited by 1,206
Wilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Hohnloser, S. H., Kuck, K.-H., & Lilienthal, J. (2000) · The Lancet · doi:10.1016/s0140-6736(00)03230-x · Cited by 1,134
Effect of Dronedarone on Cardiovascular Events in Atrial Fibrillation
Hohnloser, S. H., Crijns, H. J. G. M., van Eickels, M., Gaudin, C., Page, R. L., Torp-Pedersen, C., & Connolly, S. J. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0803778 · Cited by 1,129
Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., Bash, D., Schweikert, R., Brachmann, J., Gunther, J., et al. (2005) · JAMA · doi:10.1001/jama.293.21.2634 · Cited by 1,121 · cited 1×
“5% [15]), heart failure hospitalization (1 year: 0.”
Circumferential Pulmonary-Vein Ablation for Chronic Atrial Fibrillation
Oral, H., Pappone, C., Chugh, A., Good, E., Bogun, F., Pelosi, F., Bates, E. R., Lehmann, M. H., Vicedomini, G., Augello, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa050955 · Cited by 976
Randomized trial of rate-control versus rhythm-control in persistent atrial fibrillation
Carlsson, J. Ö., Miketic, S., Windeler, J. Ü., Cuneo, A., Haun, S., Micus, S., Walter, S., & Tebbe, U. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00332-2 · Cited by 941
Catheter Ablation Versus Antiarrhythmic Drugs for Atrial Fibrillation: The A4 Study
Jaïs, P., Cauchemez, B., Macle, L., Daoud, E., Khairy, P., Subbiah, R., Hocini, M., Extramiana, F., Sacher, F., Bordachar, P., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.772582 · Cited by 891
Wang, T. J., Massaro, J. M., Levy, D., Vasan, R. S., Wolf, P. A., D'Agostino, R. B., Larson, M. G., Kannel, W. B., & Benjamin, E. J. (2003) · JAMA · doi:10.1001/jama.290.8.1049 · Cited by 780
Pappone, C., Augello, G., Sala, S., Gugliotta, F., Vicedomini, G., Gulletta, S., Paglino, G., Mazzone, P., Sora, N., Greiss, I., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.037 · Cited by 686
Stabile, G., Bertaglia, E., Senatore, G., De Simone, A., Zoppo, F., Donnici, G., Turco, P., Pascotto, P., Fazzari, M., & Vitale, D. F. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi583 · Cited by 503
Rate Control vs Rhythm Control in Patients With Nonvalvular Persistent Atrial Fibrillation
Opolski, G., Torbicki, A., Kosior, D. A., Szulc, M., Wozakowska-Kapłon, B., Kołodziej, P., & Achremczyk, P. (2004) · Chest · doi:10.1378/chest.126.2.476 · Cited by 473
Atrial fibrillation is independently associated with senile, vascular, and Alzheimer's dementia
Bunch, T. J., Weiss, J. P., Crandall, B. G., May, H. T., Bair, T. L., Osborn, J. S., Anderson, J. L., Muhlestein, J. B., Horne, B. D., Lappe, D. L., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.12.004 · Cited by 405
Self-citationA population-based study of mortality among patients with atrial fibrillation or flutter
Vidaillet, H., Granada, J. F., Chyou, P. O.-H., Maassen, K., Ortiz, M., Pulido, J. N., Sharma, P., Smith, P. N., & Hayes, J. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01253-6 · Cited by 289
Lafuente-Lafuente, C., Mouly, S., Longás-Tejero, M. A., Mahé, I., & Bergmann, J.-F. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.7.719 · Cited by 288
Connolly, S. J., Crijns, H. J. G. M., Torp-Pedersen, C., van Eickels, M., Gaudin, C., Page, R. L., & Hohnloser, S. H. (2009) · Circulation · doi:10.1161/circulationaha.109.875252 · Cited by 261
Shelton, R. J., Clark, A. L., Goode, K., Rigby, A. S., Houghton, T., Kaye, G. C., & Cleland, J. G. F. (2009) · Heart · doi:10.1136/hrt.2008.158931 · Cited by 178
Naccarelli, G. V., Wolbrette, D. L., Khan, M., Bhatta, L., Hynes, J., Samii, S., & Luck, J. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)03375-1 · Cited by 174
Left atrial function and scar after catheter ablation of atrial fibrillation
Wylie, J. V., Peters, D. C., Essebag, V., Manning, W. J., Josephson, M. E., & Hauser, T. H. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.02.008 · Cited by 170
Schrickel, J. W., Lickfett, L., Lewalter, T., Mittmann-Braun, E. L., Selbach, S. G. M., Strach, K. A., Nähle, C. P., SCHWAB, J. O., Linhart, M., Andrié, R., et al. (2009) · EP Europace · doi:10.1093/europace/eup350 · Cited by 126
Newly Diagnosed Atrial Fibrillation
Page, R. L. (2004) · New England Journal of Medicine · doi:10.1056/nejmcp041956 · Cited by 125
Cuoco, F. A. (2010) · Yearbook of Cardiology · doi:10.1016/s0145-4145(10)79886-5 · Cited by 124
Epidemiological Profile of Atrial Fibrillation: A Contemporary Perspective
Tsang, T. S. M., Miyasaka, Y., Barnes, M. E., & Gersh, B. J. (2005) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2005.06.001 · Cited by 110
Crandall, M. A., Horne, B. D., DAY, J. D., Anderson, J. L., Muhlestein, J. B., Crandall, B. G., Weiss, J. P., OSBORNE, J. S., LAPPE, D. L., & Bunch, T. J. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02427.x · Cited by 74
Self-citationWarfarin Is Not Needed in Low‐Risk Patients Following Atrial Fibrillation Ablation Procedures
Bunch, T. J., Crandall, B. G., Weiss, J. P., May, H. T., Bair, T. L., Osborn, J. S., Anderson, J. L., LAPPE, D. L., Muhlestein, J. B., Nelson, J. S., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01481.x · Cited by 74
Self-citationThe AFFIRM Investigators (2005) · American Heart Journal · doi:10.1016/j.ahj.2004.09.038 · Cited by 71
From randomized trials to registry studies: translating data into clinical information
Brown, M. L., Gersh, B. J., Holmes, D. R., Bailey, K. R., & Sundt, T. M. (2008) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1307 · Cited by 61
Implementation of a computerized cardiovascular information system in a private hospital setting
Taylor, G. S., Muhlestein, J. B., Wagner, G. S., Bair, T. L., Li, P., & Anderson, J. L. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70123-1 · Cited by 54
Self-citationPathophysiology of concomitant atrial fibrillation and heart failure: implications for management
Morrison, T. B., Bunch, T. J., & Gersh, B. J. (2008) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1414 · Cited by 42
Self-citationValderrama, A. L., Dunbar, S. B., & Mensah, G. A. (2005) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2005.07.021 · Cited by 41
Identification, diagnosis and assessment of atrial fibrillation
Dewar, R. I., & Lip, G. Y. H. (2006) · Heart · doi:10.1136/hrt.2006.099861 · Cited by 38
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationEarly Rhythm-Control Therapy in Patients with Atrial Fibrillation
Kirchhof, P., Camm, A. J., Goette, A., Brandes, A., Eckardt, L., Elvan, A., Fetsch, T., van Gelder, I. C., Haase, D., Haegeli, L. M., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2019422 · Cited by 2,190
Packer, D. L., Mark, D. B., Robb, R. A., Monahan, K. H., Bahnson, T. D., Poole, J. E., Noseworthy, P. A., Rosenberg, Y. D., Jeffries, N., Mitchell, L. B., et al. (2019) · JAMA · doi:10.1001/jama.2019.0693 · Cited by 1,503
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citation
Metadata
- Authors
- BUNCH, T. J., CRANDALL, B. G., WEISS, J. P., MAY, H. T., BAIR, T. L., OSBORN, J. S., ANDERSON, J. L., MUHLESTEIN, J. B., HORNE, B. D., LAPPE, D. L., & DAY, J. D.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2011-03-15
- Volume
- 22
- Issue
- 8
- Pages
- 839-845
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W2073403006
- Cited by
- 398
- References
- 36
- FWCI
- 18.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.