The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Indoor particle dynamics
Open accessAbstract
UNLABELLED: Airborne particulate matter is a diverse pollutant class whose excessive presence in indoor air contributes to an array of adverse health and material-damage effects. Particles are classified according to their diameter into three size modes: ultrafine (0.1 microm), accumulation (0.1-2 microm), and coarse (= 2 microm). These modes have largely distinct sources and composition, and they exhibit different dynamic behaviors. The concept of mass conservation or material balance provides a foundation for quantitatively and mechanistically linking important outcome variables, such as concentrations and exposures, to the influencing input parameters. The factors governing indoor particle concentrations include direct emissions from indoor sources, ventilation supply from outdoor air, filtration, deposition onto indoor surfaces, and removal from indoor air by means of ventilation. In some circumstances, transport and transformation processes within indoor environments may also play an important role in influencing particle concentrations and consequences. Such processes include mixing, interzonal transport, resuspension, coagulation, and phase change. PRACTICAL IMPLICATIONS: The paper gives a practical overview of issues related to particulate matter indoors, as well as valuable information for understanding filtration and how particles contribute to adverse health effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Seinfeld, J. H., Pandis, S. N., & Noone, K. (1998) · Physics Today · doi:10.1063/1.882420 · Cited by 8,731
Atmospheric Chemistry and Physics: From Air Pollution to Climate Change
Steinfeld, J. I. (1998) · Environment: Science and Policy for Sustainable Development · doi:10.1080/00139157.1999.10544295 · Cited by 1,930
Aerosol Technology : Properties, Behavior, and Measurement of Airborne Particles
Hinds, W. C. (1982) · Cited by 1,470
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867
Self-citationDeposition, resuspension, and penetration of particles within a residence
Thatcher, T. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00016-r · Cited by 859
Wallace, L. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467451 · Cited by 698
Özkaynak, H., Xue, J., Spengler, J. D., Wallace, L. A., Pellizzari, E. D., & Jenkins, P. (1996) · PubMed · Cited by 476
Long, C. M., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2001) · Environmental Science & Technology · doi:10.1021/es001477d · Cited by 443
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Self-citationEffects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416 · cited 1×
“Among the factors that can increase particle deposition are more intense airflow and increased indoor surface area (Thatcher et al., 2002).”
BackgroundSelf-citationClearing the Air: Asthma and Indoor Air Exposures
Swanson, M. C. (2001) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)62329-0 · Cited by 393
Source Strengths for Indoor Human Activities that Resuspend Particulate Matter
Ferro, A. R., Kopperud, R. J., & Hildemann, L. M. (2004) · Environmental Science & Technology · doi:10.1021/es0263893 · Cited by 378
Characterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Long, C. M., Suh, H. H., & Koutrakis, P. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464154 · Cited by 364
Ultrafine particles and nitrogen oxides generated by gas and electric cooking
Dennekamp, M., Howarth, S., Dick, C. A. J., Cherrie, J. W., Donaldson, K., & Seaton, A. (2001) · Occupational and Environmental Medicine · doi:10.1136/oem.58.8.511 · Cited by 323
Indoor ozone/terpene reactions as a source of indoor particles
Weschler, C. J., & Shields, H. C. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00083-7 · Cited by 319
Ozone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T., Zhang, J., Weschler, C. J., & Lioy, P. J. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.001081139 · Cited by 274
Modeling pollutant penetration across building envelopes
Liu, D.-L., & Nazaroff, W. W. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00218-7 · Cited by 272
Self-citationMurray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250
Particle deposition indoors: a review
Lai, A. C. K. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01159.x · Cited by 226
A population exposure model for particulate matter: case study results for PM2.5 in Philadelphia, PA
BURKE, J. M., ZUFALL, M. J., & ÖZKAYNAK, H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500188 · Cited by 223
Particle Penetration Through Building Cracks
Liu, D.-L., & Nazaroff, W. W. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300927 · Cited by 215
Self-citationFan, Z., Lioy, P., Weschler, C., Fiedler, N., Kipen, H., & Zhang, J. (2003) · Environmental Science & Technology · doi:10.1021/es026231i · Cited by 188
Emission Factors of Carbon Monoxide and Size-Resolved Aerosols from Biofuel Combustion
Venkataraman, C., & Rao, G. U. M. (2001) · Environmental Science & Technology · doi:10.1021/es001603d · Cited by 188
Source apportionment of indoor aerosols in Suffolk and Onondaga counties, New York
Koutrakis, P., Briggs, S. L. K., & Leaderer, B. P. (1992) · Environmental Science & Technology · doi:10.1021/es00027a012 · Cited by 184
Penetration of Ambient Fine Particles into the Indoor Environment
Mosley, R. B., Greenwell, D. J., Sparks, L. E., Guo, Z., Tucker, W. G., Fortmann, R., & Whitfield, C. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117449 · Cited by 174
The transformation of outdoor ammonium nitrate aerosols in the indoor environment
Lunden, M. M., Revzan, K. L., Fischer, M. L., Thatcher, T. L., Littlejohn, D., Hering, S. V., & Brown, N. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.035 · Cited by 152
Thatcher, T. L., Lunden, M. M., Revzan, K. L., Sextro, R. G., & Brown, N. J. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300940 · Cited by 147
Characterization of Fine Particle Emissions from Burning Church Candles
Fine, P. M., Cass, G. R., & Simoneit, B. R. T. (1999) · Environmental Science & Technology · doi:10.1021/es981039v · Cited by 140
Fractional Aerosol Filtration Efficiency of In-Duct Ventilation Air Cleaners
Hanley, J., Ensor, D., Smith, D. D., & Sparks, L. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-1-00005.x · Cited by 137
Initial Size Distributions and Hygroscopicity of Indoor Combustion Aerosol Particles
Li, W., & Hopke, P. K. (1993) · Aerosol Science and Technology · doi:10.1080/02786829308959638 · Cited by 131
Indoor-outdoor relationships for airborne particulate matter of outdoor origin
Alzona, J. E., Cohen, B. L., Rudolph, H., Jow, H. N., & Frohliger, J. O. (1979) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(79)90244-0 · Cited by 128
Determining Size-Specific Emission Factors for Environmental Tobacco Smoke Particles
Klepeis, N. E., Apte, M. G., Gundel, L. A., Sextro, R. G., & Nazaroff, W. W. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300914 · Cited by 127
Self-citationGas/particle distribution of polycyclic aromatic hydrocarbons in coupled outdoor/indoor atmospheres
Naumova, Y. Y., Offenberg, J. H., Eisenreich, S. J., Meng, Q., Polidori, A., Turpin, B. J., Weisel, C. P., Morandi, M. T., Colome, S. D., Stock, T. H., et al. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00820-8 · Cited by 126
Sarwar, G., Corsi, R. L., Allen, D. T., & Weschler, C. J. (2003) · Atmospheric Environment · doi:10.1016/s1352-2310(02)01013-0 · Cited by 119
Incense Smoke: Characterization and Dynamics in Indoor Environments
Cheng, Y. S., Bechtold, W. E., Yu, C. C., & Hung, I. (1995) · Aerosol Science and Technology · doi:10.1080/02786829508965312 · Cited by 115
Fan, C.-W., & Zhang, J. J. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00399-x · Cited by 102
Environmental tobacco smoke particles in multizone indoor environments
Miller, S. L. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00506-9 · Cited by 97
Mixing of a Point Source Pollutant by Natural Convection Flow within a Room
Baughman, A. V., Gadgil, A. J., & Nazaroff, W. W. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00006.x · Cited by 97
Self-citationIndoor pollutant mixing time in an isothermal closed room: an investigation using CFD
Gadgil, A. J., Lobscheid, C., Abadie, M., & Finlayson, E. U. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.032 · Cited by 73
Weschler, C. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.022 · Cited by 68
Size distributions of submicrometer aerosols from cooking
Li, C.-S., Lin, W., & Jenq, F. (1993) · Environment International · doi:10.1016/0160-4120(93)90365-o · Cited by 68
Schneider, T., Kildes, J., & Breum, N. O. (1999) · Building and Environment · doi:10.1016/s0360-1323(98)00048-1 · Cited by 64
Mixing of a Point-Source Indoor Pollutant by Forced Convection
Drescher, A. C., Lobascio, C., Gadgil, A. J., & Nazarofif, W. W. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.t01-1-00007.x · Cited by 64
Cited by
Chen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Adams, R. I., Miletto, M., Taylor, J. W., & Bruns, T. D. (2013) · The ISME Journal · doi:10.1038/ismej.2013.28 · Cited by 939
Tran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
Indoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
SVOC exposure indoors: fresh look at dermal pathways: SVOC exposure via dermal pathways
Weschler, C. J., & Nazaroff, W. W. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00772.x · Cited by 422
Self-citation
Metadata
- Authors
- Nazaroff, W. W.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2004-08
- Volume
- 14
- Issue
- s7
- Pages
- 175-183
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2144461288
- Cited by
- 639
- References
- 43
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.