A Brain–Computer Interface Controlled Auditory Event‐Related Potential (P300) Spelling System for Locked‐In Patients
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Using brain–computer interfaces (BCI) humans can select letters or other targets on a computer screen without any muscular involvement. An intensively investigated kind of BCI is based on the recording of visual event‐related brain potentials (ERP). However, some severely paralyzed patients who need a BCI for communication have impaired vision or lack control of gaze movement, thus making a BCI depending on visual input no longer feasible. In an effort to render the ERP–BCI usable for this group of patients, the ERP–BCI was adapted to auditory stimulation. Letters of the alphabet were assigned to cells in a 5 × 5 matrix. Rows of the matrix were coded with numbers 1 to 5, and columns with numbers 6 to 10, and the numbers were presented auditorily. To select a letter, users had to first select the row and then the column containing the desired letter. Four severely paralyzed patients in the end‐stage of a neurodegenerative disease were examined. All patients performed above chance level. Spelling accuracy was significantly lower with the auditory system as compared with a similar visual system. Patients reported difficulties in concentrating on the task when presented with the auditory system. In future studies, the auditory ERP–BCI should be adjusted by taking into consideration specific features of severely paralyzed patients, such as reduced attention span. This adjustment in combination with more intensive training will show whether an auditory ERP–BCI can become an option for visually impaired patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 13×
“The authors showed that with a target probability of 25%, a P300 response to these stimuli was reliably detected, and that the response remained stable in healthy volunteers as well as in ALS patients over a period of 10 sessions, although in patients selection accuracy was lower.”
BackgroundMethodInfluentialBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Detecting awareness in the vegetative state
Owen, A. M., Coleman, M. R., Boly, M., Davis, M. H., Laureys, S., & Pickard, J. D. (2006) · Science · doi:10.1126/science.1130197 · Cited by 1,978
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 5×
“16 , 17 Both the SMR– and the SCP–BCI require learning to regulate a brain response that is achieved by means of neuro-feedback.”
BackgroundMethodInfluentialSelf-citationThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
American Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
American Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Breaking the silence: Brain-computer interfaces (BCI) for communication and motor control
Birbaumer, N. (2006) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00456.x · Cited by 722 · cited 1×
“3 , 14 Recently, efforts have been undertaken to use nonvisual stimulation for BCI control.”
BackgroundNeuper, C., Scherer, R., Reiner, M., & Pfurtscheller, G. (2005) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2005.08.014 · Cited by 721
A P300-based brain–computer interface: Initial tests by ALS patients
Sellers, E. W., & Donchin, E. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.06.027 · Cited by 711
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 2×
“28 On the other hand, the results of patient 4 indicate that even a low peak amplitude of around 1 μ V may be sufficient for above-chance classification.”
BackgroundSelf-citationPatients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539 · cited 1×
“5 , 6 , 13 However, patients examined in those studies retained at least minimal control of gaze movements.”
BackgroundSelf-citationMüller-Putz, G. R., Scherer, R., Brauneis, C., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/008 · Cited by 534
On the utility of P3 latency as an index of mental chronometry
Verleger, R. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02125.x · Cited by 515
Sellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
Fabiani, M., Gratton, G., Karis, D., & Donchin, E. (1987) · Digital Commons - University of South Florida (University of South Florida) · Cited by 458
Kübler, A., & Birbaumer, N. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.019 · Cited by 441
Self-citationAn auditory brain–computer interface (BCI)
Nijboer, F., Furdea, A., Gunst, I., Mellinger, J., McFarland, D. J., Birbaumer, N., & Kübler, A. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.02.009 · Cited by 405
Self-citationBrain-computer communication: Self-regulation of slow cortical potentials for verbal communication
Kübler, A., Neumann, N., Kaiser, J., Kotchoubey, B., Hinterberger, T., & Birbaumer, N. P. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.26621 · Cited by 350
Self-citationAn auditory oddball (P300) spelling system for brain‐computer interfaces
Furdea, A., Halder, S., Krusienski, D. J., Bross, D., Nijboer, F., Birbaumer, N., & Kübler, A. (2009) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00783.x · Cited by 326
Self-citationKotchoubey, B., Lang, S., Mezger, G., Schmalohr, D., Schneck, M., Semmler, A., Bostanov, V., & Birbaumer, N. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.03.028 · Cited by 315
Self-citationSteady-state somatosensory evoked potentials: suitable brain signals for brain-computer interfaces?
Muller-Putz, G. R., Scherer, R., Neuper, C., & Pfurtscheller, G. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.863842 · Cited by 288
The Neurology of Consciousness
(2009) · doi:10.1016/b978-0-12-374168-4.x0001-9 · Cited by 241
Total manifestations of amyotrophic lateral sclerosis
Hayashi, H., & Kato, S. (1989) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(89)90158-5 · Cited by 184
A multimodal brain-based feedback and communication system
Hinterberger, T., Neumann, N., Pham, M., K�bler, A., Grether, A., Hofmayer, N., Wilhelm, B., Flor, H., & Birbaumer, N. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1690-3 · Cited by 171
Self-citationSellers, E. W., Kubler, A., & Donchin, E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875580 · Cited by 160
Vibrotactile Feedback for Brain-Computer Interface Operation
Cincotti, F., Kauhanen, L., Aloise, F., Palomäki, T., Caporusso, N., Jylänki, P., Mattia, D., Babiloni, F., Vanacker, G., Nuttin, M., et al. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/48937 · Cited by 160
Brain-computer interface (BCI) operation: signal and noise during early training sessions
McFarland, D. J., Sarnacki, W. A., Vaughan, T. M., & Wolpaw, J. R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.07.004 · Cited by 157
An Auditory Paradigm for Brain--Computer Interfaces
Hill, N. J., Lal, T. N., Bierig, K., Birbaumer, N., Schölkopf, B., Saul, L. K., Weiss, Y., & Bottou, L. (2005) · Max Planck Institute for Plasma Physics · Cited by 111
Brain–computer interfaces in the continuum of consciousness
Kübler, A., & Kotchoubey, B. (2007) · Current Opinion in Neurology · doi:10.1097/wco.0b013e3282f14782 · Cited by 77
Self-citationEvent-Related Auditory Evoked Potentials and Amyotrophic Lateral Sclerosis
Gil, R., Neau, J. ‐., Dary-Auriol, M., Agbo, C., Tantot, A.-M., & Ingrand, P. (1995) · Archives of Neurology · doi:10.1001/archneur.1995.00540330068017 · Cited by 48
Kübler, A. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374168-4.00017-4 · Cited by 34
Self-citationDesprés, O., Candas, V., & Dufour, A. (2004) · Cognitive Brain Research · doi:10.1016/j.cogbrainres.2004.10.014 · Cited by 31
Etude du sommeil nocturne au cours de l'encephalopathie porto-cave
Kurtz, D., Jp, Z., Imler, M., Girardel, M., Grinspan, G., Peter, B., & Rohmer, F. (1972) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(72)90044-2 · Cited by 31
Event‐related brain potentials in a varied‐set memory search task: A reconsideration
Kotchoubey, B., Jordan, J. S., Grözinger, B., Westphal, K. P., & Kornhuber, H. H. (1996) · Psychophysiology · doi:10.1111/j.1469-8986.1996.tb02429.x · Cited by 31
Self-citationBrain responses to number sequences with and without active task requirement
Lang, S., & Kotchoubey, B. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00267-5 · Cited by 30
Self-citationBrain-Computer Interfaces for Communication in Paralysis: A Clinical Experimental Approach
Hinterberger, T., Nijboer, F., Kübler, A., Matuz, T., Furdea, A., Mochty, U., Jordan, M., Lal, T., Hill, J., Mellinger, J., et al. (2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.003.0006 · Cited by 13
Self-citationResearchArticle Vibrotactile Feedback for Brain-Computer Interface Operation
Febo Cincotti, A., Kauhanen, L., Fabio Aloise, A., Palom, T., Caporusso, N., Jyl, P., Donatella Mattia, A., Babiloni, F., Vanacker, G., Nuttin, M., et al. (2007) · Cited by 9
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“make P300 spellers suitable for this group of patients [129,272–274].”
BackgroundBrain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928
A novel deep learning approach for classification of EEG motor imagery signals
Tabar, Y. R., & Halici, U. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016003 · Cited by 859
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Metadata
- Authors
- Kübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 1157
- Issue
- 1
- Pages
- 90-100
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W2163727886
- Cited by
- 303
- References
- 42
- FWCI
- 9.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.