A Brain–Computer Interface Controlled Auditory Event‐Related Potential (P300) Spelling System for Locked‐In Patients
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Using brain–computer interfaces (BCI) humans can select letters or other targets on a computer screen without any muscular involvement. An intensively investigated kind of BCI is based on the recording of visual event‐related brain potentials (ERP). However, some severely paralyzed patients who need a BCI for communication have impaired vision or lack control of gaze movement, thus making a BCI depending on visual input no longer feasible. In an effort to render the ERP–BCI usable for this group of patients, the ERP–BCI was adapted to auditory stimulation. Letters of the alphabet were assigned to cells in a 5 × 5 matrix. Rows of the matrix were coded with numbers 1 to 5, and columns with numbers 6 to 10, and the numbers were presented auditorily. To select a letter, users had to first select the row and then the column containing the desired letter. Four severely paralyzed patients in the end‐stage of a neurodegenerative disease were examined. All patients performed above chance level. Spelling accuracy was significantly lower with the auditory system as compared with a similar visual system. Patients reported difficulties in concentrating on the task when presented with the auditory system. In future studies, the auditory ERP–BCI should be adjusted by taking into consideration specific features of severely paralyzed patients, such as reduced attention span. This adjustment in combination with more intensive training will show whether an auditory ERP–BCI can become an option for visually impaired patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 13×
“The authors showed that with a target probability of 25%, a P300 response to these stimuli was reliably detected, and that the response remained stable in healthy volunteers as well as in ALS patients over a period of 10 sessions, although in patients selection accuracy was lower.”
BackgroundMethodInfluentialBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Detecting awareness in the vegetative state
Owen, A. M., Coleman, M. R., Boly, M., Davis, M. H., Laureys, S., & Pickard, J. D. (2006) · Science · doi:10.1126/science.1130197 · Cited by 1,978
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 5×
“16 , 17 Both the SMR– and the SCP–BCI require learning to regulate a brain response that is achieved by means of neuro-feedback.”
BackgroundMethodInfluentialSelf-citationThe mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
American Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
American Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
Toward Brain-Computer Interfacing
(2007) · The MIT Press eBooks · doi:10.7551/mitpress/7493.001.0001 · Cited by 785
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“make P300 spellers suitable for this group of patients [129,272–274].”
BackgroundBrain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928
A novel deep learning approach for classification of EEG motor imagery signals
Tabar, Y. R., & Halici, U. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2560/14/1/016003 · Cited by 859
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
“However, mean accuracy was 65.53% in this condition; thus this level of accuracy is not sufficient for effective communication, as 70% is typically assumed to be required (K} ubler et al., 2001, 2009; Sellers et al., 2006).”
BackgroundInfluentialClinical Applications of Brain-Computer Interfaces: Current State and Future Prospects
Mak, J. N., & Wolpaw, J. R. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2035356 · Cited by 509
Simon, N., Käthner, I., Ruf, C. A., Pasqualotto, E., Kübler, A., & Halder, S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.01039 · Cited by 478
Self-citationVisual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
(C)overt attention and visual speller design in an ERP-based brain-computer interface
Treder, M. S., & Blankertz, B. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-28 · Cited by 362
P300 brain computer interface: current challenges and emerging trends
Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00014 · Cited by 359
Self-citationAllison, B. Z., & Neuper, C. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_3 · Cited by 350
Lazarou, I., Nikolopoulos, S., Petrantonakis, P. C., Kompatsiaris, I., & Tsolaki, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00014 · Cited by 335
EEG-Based Emotion Classification Using a Deep Neural Network and Sparse Autoencoder
Liu, J., Wu, G., Luo, Y., Qiu, S., Yang, S., Li, W., & Bi, Y. (2020) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2020.00043 · Cited by 260
SSVEP-based Bremen–BCI interface—boosting information transfer rates
Volosyak, I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036020 · Cited by 232
“people with severe motor disabilities [4, 5].”
Huggins, J. E., Wren, P. A., & Gruis, K. L. (2011) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482968.2011.572978 · Cited by 215
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
Mak, J. N., Arbel, Y., Minett, J. W., McCane, L. M., Yuksel, B., Ryan, D., Thompson, D., Bianchi, L., & Erdogmus, D. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025003 · Cited by 195
“…by results from young healthy adults while reports from users with disabilities are limited (Sellers and Donchin 2006, Piccione et al 2006, Kubler and Birbaumer 2008, Nijboer et al 2008, Silvoni et al 2009, Sellers et al 2006b, 2010, Hoffmann et al 2008, Kubler et al 2009, Townsend et al 2010).”
BackgroundLulé, D., Noirhomme, Q., Kleih, S. C., Chatelle, C., Halder, S., Demertzi, A., Bruno, M.-A., Gosseries, O., Vanhaudenhuyse, A., Schnakers, C., et al. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.04.030 · Cited by 189
“To date, few studies with non-visually based P3-BCI exist (e.g., see Klobassa et al., 2009; Furdea et al., 2009; Kübler et al., 2009; Schreuder et al., 2011 for auditory BCIs).”
Self-citationBCI Demographics II: How Many (and What Kinds of) People Can Use a High-Frequency SSVEP BCI?
Volosyak, I., Valbuena, D., Luth, T., Malechka, T., & Graser, A. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2121919 · Cited by 175
“These devices use brain activity as an input signal and may be the only possible way of communication for severely disabled users, such as persons suffering from Cerebral Palsy, stroke victims, or persons with injuries of the brain or spinal cord [ 3 ], [4].”
BackgroundLin, S., Liu, J., Li, W., Wang, D., Huang, Y., Jia, C., Li, Z., Murtaza, M., Wang, H., Song, J., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02019 · Cited by 171
Evolving Signal Processing for Brain–Computer Interfaces
Makeig, S., Kothe, C., Mullen, T., Bigdely-Shamlo, N., Zhang, Z., & Kreutz-Delgado, K. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2185009 · Cited by 163
“Not surprisingly, such systems were widely considered to be of foreseeable practical use only to a relatively few cognitively intact ‘locked-in’ users suffering near-complete loss of muscular control [47][48].”
BackgroundAn adaptive P300-based control system
Jin, J., Allison, B. Z., Sellers, E. W., Brunner, C., Horki, P., Wang, X., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036006 · Cited by 158
“Using a calibration data set from each participant, they determined the optimal number of trials per average for each participant using a metric referred to as the written symbol rate (WSR) (K¨ubler et al 2009).”
BackgroundMethodMcCane, L. M., Heckman, S. M., McFarland, D. J., Townsend, G., Mak, J. N., Sellers, E. W., Zeitlin, D., Tenteromano, L. M., Wolpaw, J. R., & Vaughan, T. M. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.01.013 · Cited by 141
Detecting Consciousness: A Unique Role for Neuroimaging
Owen, A. M. (2013) · Annual Review of Psychology · doi:10.1146/annurev-psych-113011-143729 · Cited by 122
“Locked-in patients with ALS could use this system to communicate (Kübler et al. 2009), although classification accuracies were lower in the auditory than in the visual domain.”
MethodBrain-Computer Interface: Applications to Speech Decoding and Synthesis to Augment Communication
Luo, S., Rabbani, Q., & Crone, N. E. (2022) · Neurotherapeutics · doi:10.1007/s13311-022-01190-2 · Cited by 106
Neurofeedback Training for BCI Control
Neuper, C., & Pfurtscheller, G. (2009) · The Frontiers Collection · doi:10.1007/978-3-642-02091-9_4 · Cited by 102
“Kubler et al. [ 66 ] and Furdea et al. [67] showed that P300 BCIs could also be implemented with auditory rather than visual feedback.”
Effects of training and motivation on auditory P300 brain-computer interface performance
Baykara, E., Ruf, C. A., Fioravanti, C., Käthner, I., Simon, N., Kleih, S. C., Kübler, A., & Halder, S. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.054 · Cited by 91
“(2009) Auditory 36 59.4 1.86 Online Healthy Kübler et al. (2009) Auditory 25 12.1 0.05 Online ALS patients Halder et al. (2010) Auditory 2 78.5 2.46 Offline Healthy Höhne et al. (2011) Auditory 9 89.4 4.61 Online Healthy Schreuder et al.”
MethodInfluentialSelf-citationClinical evaluation of BrainTree, a motor imagery hybrid BCI speller
Perdikis, S., Leeb, R., Williamson, J., Ramsay, A., Tavella, M., Desideri, L., Hoogerwerf, E.-J., Al-Khodairy, A., Murray-Smith, R., & Millán, J. D. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036003 · Cited by 85
“[19], 5 in [20], 4 in [21], 3 in [4] and [22], 1 in [23].”
Brain-Computer Interfaces for Communication: Preferences of Individuals With Locked-in Syndrome
Branco, M. P., Pels, E. G. M., Sars, R. H., Aarnoutse, E. J., Ramsey, N. F., Vansteensel, M. J., & Nijboer, F. (2021) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968321989331 · Cited by 61
Self-citationReichert, C., Tellez Ceja, I. F., Sweeney-Reed, C. M., Heinze, H.-J., Hinrichs, H., & Dürschmid, S. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.591777 · Cited by 23
“For this reason, auditory (Kübler et al., 2009; Halder et al., 2010, 2016; Hill et al., 2014) and tactile variants (Brouwer and van Erp, 2010; Jin et al., 2020) of the oddball paradigm have been investigated, with the finding that they provide inferior performance compared to BCIs based on visual…”
Guo, M., Jin, J., Jiao, Y., Wang, X., & Cichockia, A. (2019) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2019.00024 · Cited by 18
“…divided into several categories according to the types of signals used, especially ERP-based BCI (Farwell and Donchin, 1988; Furdea et al., 2009; Kübler et al., 2009; Zhang et al., 2012; including P300-BCI), motor imagery BCI (Pfurtscheller and Neuper, 2001; Wang et al., 2006; Hwang et al.,…”
Method
Metadata
- Authors
- Kübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 1157
- Issue
- 1
- Pages
- 90-100
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W2163727886
- Cited by
- 303
- References
- 42
- FWCI
- 9.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.