CoChat

Sex differences in fatigability following exercise normalised to the power–duration relationship

Open access
Ansdell, Paul, Škarabot, Jakob, Atkinson, Elliott, Corden, Sarah, Tygart, Amber, Hicks, Kirsty M, Thomas, Kevin, Hunter, Sandra K, Howatson, Glyn, Goodall, Stuart · 2020 · The Journal of Physiology
Cited by 97

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

Key points: Knee‐extensors demonstrate greater fatigue resistance in females compared to males during single‐limb and whole‐body exercise. For single‐limb exercise, the intensity–duration relationship is different between sexes, with females sustaining a greater relative intensity of exercise. This study established the power–duration relationship during cycling, then assessed fatigability during critical power‐matched exercise within the heavy and severe intensity domains. When critical power and the curvature constant were expressed relative to maximal ramp test power, no sex difference was observed. No sex difference in time to task failure was observed in either trial. During heavy and severe intensity cycling, females experienced lesser muscle de‐oxygenation. Following both trials, females experienced lesser reductions in knee‐extensor contractile function, and following heavy intensity exercise, females experienced less reduction in voluntary activation. These data demonstrate that whilst the relative power–duration relationship is not different between males and females, the mechanisms of fatigability during critical power‐matched exercise are mediated by sex. Due to morphological differences, females demonstrate greater fatigue resistance of locomotor muscle during single‐limb and whole‐body exercise modalities. Whilst females sustain a greater relative intensity of single‐limb, isometric exercise than males, limited investigation has been performed during whole‐body exercise. Accordingly, this study established the power–duration relationship during cycling in 18 trained participants (eight females). Subsequently, constant‐load exercise was performed at critical power (CP)‐matched intensities within the heavy and severe domains, with the mechanisms of fatigability assessed via non‐invasive neurostimulation, near‐infrared spectroscopy and pulmonary gas exchange during and following exercise. Relative CP (72 ± 5 vs. 74 ± 2% P max, P = 0.210) and curvature constant (51 ± 11 vs. 52 ± 10 J P max−1, P = 0.733) of the power–duration relationship were similar between males and females. Subsequent heavy (P = 0.758) and severe intensity (P = 0.645) exercise time to task failures were not different between sexes. However, females experienced lesser reductions in contractile function at task failure (P ≤ 0.020), and greater vastus lateralis oxygenation (P ≤ 0.039) during both trials. Reductions in voluntary activation occurred following both trials (P < 0.001), but were less in females following the heavy trial (P = 0.036). Furthermore, during the heavy intensity trial only, corticospinal excitability was reduced at the cortical (P = 0.020) and spinal (P = 0.036) levels, but these reductions were not sex‐dependent. Other than a lower respiratory exchange ratio in the heavy trial for females (P = 0.039), no gas exchange variables differed between sexes (P ≥ 0.052). Collectively, these data demonstrate that whilst the relative power–duration relationship is not different between males and females, the mechanisms of fatigability during CP‐matched exercise above and below CP are mediated by sex.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jp280031

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 97

Metadata

Authors
Ansdell, P., Škarabot, J., Atkinson, E., Corden, S., Tygart, A., Hicks, K. M., Thomas, K., Hunter, S. K., Howatson, G., & Goodall, S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2020-09-26
Volume
598
Issue
24
Pages
5717-5737
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W3085673473
Cited by
97
References
18
FWCI
11.59
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.