Abstract
1. A theoretical and experimental analysis of the relationship of the corneal stromal ultrastructure with light transmission has been made in an attempt to resolve recent contradictory explanations of corneal transparency. 2. The spatial distribution of collagen fibrils in electronmicrographs of rabbit corneal stroma has been analysed in terms of a radial distribution function. The results indicate the presence of local order extending to at least 200 nm from individual fibrils. 3. The observed spatial distribution of the collagen fibrils was used as a basis to compare the theoretically derived and the experimentally determined values of light transmission. It has been found that the transparency of the normal cornea may be explained by the quasi‐random structure revealed by the electronmicroscope. 4. Histograms of the collagen fibril diameter in normal rabbit corneal stroma revealed the range to be 12·5–32·5 nm and the mean value to be approximately 20 ± 1·5 nm. Corneal swelling did not change the collagen fibril diameter significantly. 5. It is concluded that the size and distribution of collagen fibrils revealed in electronmicrographs are consistent with the observed transparency of normal stromas. 6. A marked heterogeneity in the spatial distribution of collagen fibrils was found in the swollen cornea. This is qualitatively consistent with the observed decrease in transparency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The structure and transparency of the cornea
Maurice, D. M. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005758 · Cited by 1,129 · cited 2×
“Maurice, 1957) and CO 0 05 (Maurice, 1957) to 0-1 (Smith, 1969) is the concentration of (non-collagenous) organic material in the stroma.”
BackgroundLight scattering in the cornea
Hart, R. W., & Farrell, R. A. (1969) · Journal of the Optical Society of America · doi:10.1364/josa.59.000766 · Cited by 237
Self-citation
Cited by
The Multicomposite Structure of Tendon
Kastelic, J., Galeski, A., & Baer, E. (1978) · Connective Tissue Research · doi:10.3109/03008207809152283 · Cited by 689
Collagen fibrillogenesis in vitro: interaction of types I and V collagen regulates fibril diameter
Birk, D. E., Fitch, J. M., Babiarz, J. P., Doane, K. J., & Linsenmayer, T. F. (1990) · Journal of Cell Science · doi:10.1242/jcs.95.4.649 · Cited by 596
The physics and biology of animal reflectors
Land, M. F. (1972) · Progress in Biophysics and Molecular Biology · doi:10.1016/0079-6107(72)90004-1 · Cited by 596
Light propagation in tissues with controlled optical properties
Tuchin, V. V. (1997) · Journal of Biomedical Optics · doi:10.1117/1.429841 · Cited by 411
Collagen type I and type V are present in the same fibril in the avian corneal stroma.
Birk, D. E., Fitch, J. M., Babiarz, J. P., & Linsenmayer, T. F. (1988) · The Journal of cell biology · doi:10.1083/jcb.106.3.999 · Cited by 391
Human limbal biopsy–derived stromal stem cells prevent corneal scarring
Basu, S., Hertsenberg, A. J., Funderburgh, M. L., Burrow, M. K., Mann, M. M., Du, Y., Lathrop, K. L., Syed-Picard, F. N., Adams, S. M., Birk, D. E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009644 · Cited by 270
Hashimoto, Y., Funamoto, S., Sasaki, S., Honda, T., Hattori, S., Nam, K., Kimura, T., Mochizuki, M., Fujisato, T., Kobayashi, H., et al. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.122 · Cited by 251
“In addition, corneal transparency is explained by lattice theory [32,33] that is, based on the corneal structure, collagen fibrils align regularly and make a kind of optically clear lattice of the collagen matrix.”
BackgroundCorneal collagen—its role in maintaining corneal shape and transparency
Meek, K. M. (2009) · Biophysical Reviews · doi:10.1007/s12551-009-0011-x · Cited by 183
“The fact that narrower fibrils are more closely spaced may also be related to optical properties of the cornea (Cox et al. 1970; Benedek 1971).”
Ultrastructure of the corneal stroma: a comparative study
Meek, K. M., & Leonard, D. W. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81364-x · Cited by 166
Twersky, V. (1975) · Journal of the Optical Society of America · doi:10.1364/josa.65.000524 · Cited by 159
Glucose and Mannitol Diffusion in Human Dura Mater
Bashkatov, A. N., Genina, E. A., Sinichkin, Y. P., Kochubey, V. I., Lakodina, N. A., & Tuchin, V. V. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74750-x · Cited by 159
“The number of the scattering particles per unit area can be estimated as N ¼ f/(pa2) (Cox et al., 1970), where f is the volume fraction of the tissue scatterers.”
BackgroundMethodInfluentialRefractive indices of the collagen fibrils and extrafibrillar material of the corneal stroma
Leonard, D. W., & Meek, K. M. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78784-8 · Cited by 158
Farrell, R. A., McCally, R. L., & Tatham, P. E. R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010325 · Cited by 126
Self-citationDoutch, J., Quantock, A. J., Smith, V. A., & Meek, K. M. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.132316 · Cited by 65
Mechanisms of self-organization for the collagen fibril lattice in the human cornea
Cheng, X., & Pinsky, P. M. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0512 · Cited by 53
The precision of lateral size control in the assembly of corneal collagen fibrils
Holmes, D. F., & Kadler, K. E. (2005) · Journal of Molecular Biology · doi:10.1016/j.jmb.2004.10.078 · Cited by 30
Effect of transcorneal pressure on small-angle light scattering from rabbit cornea
McCally, R. L., & Farrell, R. A. (1977) · Polymer · doi:10.1016/0032-3861(77)90159-8 · Cited by 8
Self-citation
Metadata
- Authors
- Cox, J. L., Farrell, R. A., Hart, R. W., & Langham, M. E.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1970-10
- Volume
- 210
- Issue
- 3
- Pages
- 601-616
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2140237791
- Cited by
- 145
- References
- 2
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.