A study of desensitization of acetylcholine receptors using nerve‐released transmitter in the frog
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
1. Desensitization of acetylcholine (ACh) receptors was studied at the frog neuromuscular junction under voltage clamp. 2. ACh was applied directly to junctional receptors by stimulating the motor nerve with trains of impulses. End‐plate currents (e.p.c.s) were used to estimate the total number of channel openings by the junctional ACh receptors, and miniature end‐plate currents (m.e.p.c.s) were used to measure changes in post‐synaptic sensitivity. Under the conditions of these experiments the changes in m.e.p.c. amplitudes were shown to be post‐synaptic in origin and thus provided a measure of desensitization. 3. When the acetylcholinesterase was inhibited with diisopropylfluorophosphate, neostigmine, or collagenase treatment to prolong the duration of the nerve‐released ACh in the synaptic cleft, desensitization developed during repetitive stimulation of 1000 impulses at 5‐33 impulses/sec and then recovered after the conditioning trains, with a time constant of about 25 sec. 4. When the acetylcholinesterase was active so that the duration of ACh in the synaptic cleft resulting from each nerve impulse was brief (< 300 μsec), desensitization developed in response to 300‐500 pairs of nerve stimuli if the interval between the impulses of each pair was 25 msec or less. When the interval was 30 msec or greater, however, measurable desensitization did not occur, even if the total number of channel openings was many times greater than in the experiments with shorter intervals or inhibited esterase where desensitization readily occurred. 5. The desensitization observed to pairs of impulses was enhanced by chlorpromazine and decreased when the post‐synaptic membrane was depolarized, properties similar to those described previously for desensitization to bath and ionophoretic application of ACh. 6. These results indicate that desensitization to nerve‐released transmitter is not a simple consequence of receptor activation, is not due to blockade of the open receptor channels by ACh, and does not result from ACh binding directly to desensitized receptors with a resulting shift in the receptor population towards the desensitized state. 7. We suggest that the desensitization observed to nerve‐released transmitter is a two‐step process with both steps initiated by ACh. In the first step ACh converts some receptors into a desensitizable state which has an apparent lifetime of less than 30 msec; in the second step ACh desensitizes the desensitizable state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A study of the ‘desensitization’ produced by acetylcholine at the motor end‐plate
Katz, B., & Thesleff, S. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005838 · Cited by 1,461
Anderson, C. R., & Stevens, C. F. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010410 · Cited by 986
A quantitative description of end‐plate currents
Magleby, K. L., & Stevens, C. F. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009840 · Cited by 616
Self-citationSakmann, B., Patlak, J., & Neher, E. (1980) · Nature · doi:10.1038/286071a0 · Cited by 600
The binding of acetylcholine to receptors and its removal from the synaptic cleft
Katz, B., & Miledi, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010248 · Cited by 574
Interaction at end-plate receptors between different choline derivatives
Castillo, J. D., & Katz, B. (1957) · Proceedings of the Royal Society of London. Series B - Biological Sciences · doi:10.1098/rspb.1957.0018 · Cited by 470
The effect of voltage on the time course of end‐plate currents
Magleby, K. L., & Stevens, C. F. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009839 · Cited by 442
Self-citationOn the permeability of end‐plate membrane during the action of transmitter
Takeuchi, A., & Takeuchi, N. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006564 · Cited by 429
The permeability of endplate channels to monovalent and divalent metal cations.
Adams, D. J., Dwyer, T. M., & Hille, B. (1980) · The Journal of general physiology · doi:10.1085/jgp.75.5.493 · Cited by 331
THESLEFF, S. (1955) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1955.tb01242.x · Cited by 281
Cited by
Short-Term Synaptic Plasticity
Zucker, R. S., & Regehr, W. G. (2002) · Annual Review of Physiology · doi:10.1146/annurev.physiol.64.092501.114547 · Cited by 5,068
Acetylcholine Receptor: An Allosteric Protein
Changeux, J.-P., Devillers-Thiéry, A., & Chemouilli, P. (1984) · Science · doi:10.1126/science.6382611 · Cited by 623
Desensitized states prolong GABAA channel responses to brief agonist pulses
Jones, M. V., & Westbrook, G. L. (1995) · Neuron · doi:10.1016/0896-6273(95)90075-6 · Cited by 583
The impact of receptor desensitization on fast synaptic transmission
Jones, M. V., & Westbrook, G. L. (1996) · Trends in Neurosciences · doi:10.1016/s0166-2236(96)80037-3 · Cited by 470
Desensitization of AMPA receptors upon multiquantal neurotransmitter release
Trussell, L. O., Zhang, S., & Ramant, I. M. (1993) · Neuron · doi:10.1016/0896-6273(93)90066-z · Cited by 464
Glutamate receptor desensitization and its role in synaptic transmission
Trussell, L. O., & Fischbach, G. D. (1989) · Neuron · doi:10.1016/0896-6273(89)90034-2 · Cited by 456
Neuromuscular fatigue in healthy muscle: Underlying factors and adaptation mechanisms
Boyas, S., & Guével, A. (2011) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2011.01.001 · Cited by 324
von Gersdorff, H., Schneggenburger, R., Weis, S., & Neher, E. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-21-08137.1997 · Cited by 277
Sine, S. M., Ohno, K., Bouzat, C., Auerbach, A., Milone, M., Pruitt, J. N., & Engel, A. G. (1995) · Neuron · doi:10.1016/0896-6273(95)90080-2 · Cited by 270
Congenital Myasthenic Syndromes
Engel, A. G. (2011) · Neuromuscular Disorders · doi:10.1002/9781119973331.ch19 · Cited by 237
Sakaba, T., & Neher, E. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-02-00462.2001 · Cited by 217
“In the neuromuscular junction, deconvolution of the EPSCs with the miniature EPSC (mEPSC) gives an accurate estimate of the time course of transmitter release (van der Kloot 1988a,b), because the released quanta do not interact with each other (Hartzell et al., 1975; Magleby and Pallotta, 1981).”
MethodWilson, G. G., & Karlin, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.3.1241 · Cited by 138
A kinetic mechanism for nicotinic acetylcholine receptors based on multiple allosteric transitions.
Edelstein, S. J., Schaad, O., Henry, E., Bertrand, D., & Changeux, J.-P. (1996) · Biological Cybernetics · doi:10.1007/s004220050302 · Cited by 134
“…from studies both in vitro and in vivo indicates that even after brief pulses, small, but finite amounts of the receptor population remain in desensitized states (Magleby and Pallotta 1981; Colquhoun et al. 1992; Hestrin 1993), thereby constituting a short-term remembrance of the transient opening.”
BackgroundReitstetter, R., Lukas, R. J., & Gruener, R. (1999) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)38184-4 · Cited by 87
“Desensitization can also occur without channel activation, thus bypassing the open state (Magleby and Pallotta, 1981; Changeux, 1990).”
Metadata
- Authors
- Magleby, K. L., & Pallotta, B. S.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1981-07
- Volume
- 316
- Issue
- 1
- Pages
- 225-250
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1994188838
- Cited by
- 173
- References
- 33
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.