CoChat

A study of desensitization of acetylcholine receptors using nerve‐released transmitter in the frog

Open access
Magleby, K. L., Pallotta, B. S. · 1981 · The Journal of Physiology
Cited by 173

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

1. Desensitization of acetylcholine (ACh) receptors was studied at the frog neuromuscular junction under voltage clamp. 2. ACh was applied directly to junctional receptors by stimulating the motor nerve with trains of impulses. End‐plate currents (e.p.c.s) were used to estimate the total number of channel openings by the junctional ACh receptors, and miniature end‐plate currents (m.e.p.c.s) were used to measure changes in post‐synaptic sensitivity. Under the conditions of these experiments the changes in m.e.p.c. amplitudes were shown to be post‐synaptic in origin and thus provided a measure of desensitization. 3. When the acetylcholinesterase was inhibited with diisopropylfluorophosphate, neostigmine, or collagenase treatment to prolong the duration of the nerve‐released ACh in the synaptic cleft, desensitization developed during repetitive stimulation of 1000 impulses at 5‐33 impulses/sec and then recovered after the conditioning trains, with a time constant of about 25 sec. 4. When the acetylcholinesterase was active so that the duration of ACh in the synaptic cleft resulting from each nerve impulse was brief (< 300 μsec), desensitization developed in response to 300‐500 pairs of nerve stimuli if the interval between the impulses of each pair was 25 msec or less. When the interval was 30 msec or greater, however, measurable desensitization did not occur, even if the total number of channel openings was many times greater than in the experiments with shorter intervals or inhibited esterase where desensitization readily occurred. 5. The desensitization observed to pairs of impulses was enhanced by chlorpromazine and decreased when the post‐synaptic membrane was depolarized, properties similar to those described previously for desensitization to bath and ionophoretic application of ACh. 6. These results indicate that desensitization to nerve‐released transmitter is not a simple consequence of receptor activation, is not due to blockade of the open receptor channels by ACh, and does not result from ACh binding directly to desensitized receptors with a resulting shift in the receptor population towards the desensitized state. 7. We suggest that the desensitization observed to nerve‐released transmitter is a two‐step process with both steps initiated by ACh. In the first step ACh converts some receptors into a desensitizable state which has an apparent lifetime of less than 30 msec; in the second step ACh desensitizes the desensitizable state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1981.sp013784

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

Metadata

Authors
Magleby, K. L., & Pallotta, B. S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1981-07
Volume
316
Issue
1
Pages
225-250
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1994188838
Cited by
173
References
33
FWCI
3.05
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.