The DOI matches its Crossref record.
Optimum Settings for Automatic Controllers
Abstract
In this paper, the three principal control effects found in present controllers are examined and practical names and units of measurement are proposed for each effect. Corresponding units are proposed for a classification of industrial processes in terms of the two principal characteristics affecting their controllability. Formulas are given which enable the controller settings to be determined from the experimental or calculated values of the lag and unit reaction rate of the process to be controlled. These units form the basis of a quick method for adjusting a controller on the job. The effect of varying each controller setting is shown in a series of chart records. It is believed that the conceptions of control presented in this paper will be of assistance in the adjustment of existing controller applications and in the design of new installations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PID control system analysis, design, and technology
Ang, K. H., Chong, G., & Li, Y. (2005) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2005.847331 · Cited by 2,983
Simple analytic rules for model reduction and PID controller tuning
Skogestad, S. (2003) · Journal of Process Control · doi:10.1016/s0959-1524(02)00062-8 · Cited by 2,006
Feedback systems: an introduction for scientists and engineers
(2008) · Choice Reviews Online · doi:10.5860/choice.46-2107 · Cited by 1,968
Automatic tuning of simple regulators with specifications on phase and amplitude margins
Åström, K. J., & Hägglund, T. (1984) · Automatica · doi:10.1016/0005-1098(84)90014-1 · Cited by 1,834
From model-based control to data-driven control: Survey, classification and perspective
Hou, Z.-S., & Wang, Z. (2013) · Information Sciences · doi:10.1016/j.ins.2012.07.014 · Cited by 1,405
Virtual reference feedback tuning: a direct method for the design of feedback controllers
Campi, M. C., Lecchini, A., & Savaresi, S. M. (2002) · Automatica · doi:10.1016/s0005-1098(02)00032-8 · Cited by 1,110
Åström, K. J., & Hägglund, T. (2026) · Wiley eBooks · doi:10.1002/9781394442102 · Cited by 1,103
Revisiting the Ziegler–Nichols step response method for PID control
Åström, K. J., & Hägglund, T. (2004) · Journal of Process Control · doi:10.1016/j.jprocont.2004.01.002 · Cited by 1,038
A review of PID control, tuning methods and applications
Borase, R. P., Maghade, D. K., Sondkar, S. Y., & Pawar, S. N. (2021) · International Journal of Dynamics and Control · doi:10.1007/s40435-020-00665-4 · Cited by 1,036
Handbook of Pi and Pid Controller Tuning Rules
O’Dwyer, A. (2006) · IMPERIAL COLLEGE PRESS eBooks · doi:10.1142/9781860949104 · Cited by 1,015
Formulas for Data-Driven Control: Stabilization, Optimality, and Robustness
De Persis, C., & Tesi, P. (2020) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2019.2959924 · Cited by 983
Fuzzy gain scheduling of PID controllers
Zhao, Z.-Y., Tomizuka, M., & Isaka, S. (1993) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.260670 · Cited by 775
Cyber–Physical Systems: A Perspective at the Centennial
Kim, K.-D., & Kumar, P. R. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2189792 · Cited by 761
Survey on Recent Results in the Stability and Control of Time-Delay Systems*
Gu, K., & Niculescu, S.-I. (2003) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.1569950 · Cited by 629
Data Informativity: A New Perspective on Data-Driven Analysis and Control
van Waarde, H. J., Eising, J., Trentelman, H. L., & Camlibel, M. K. (2020) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2020.2966717 · Cited by 514
Reinforcement Learning for UAV Attitude Control
Koch, W., Mancuso, R., West, R., & Bestavros, A. (2019) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3301273 · Cited by 499
Metaheuristic algorithms for PID controller parameters tuning: review, approaches and open problems
Joseph, S. B., Dada, E. G., Abidemi, A., Oyewola, D. O., & Khammas, B. M. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e09399 · Cited by 458
PI/PID Controller Design Based on Direct Synthesis and Disturbance Rejection
Chen, D., & Seborg, D. E. (2002) · Industrial & Engineering Chemistry Research · doi:10.1021/ie010756m · Cited by 430
FLIESS, M., & JOIN, C. (2009) · IFAC Proceedings Volumes · doi:10.3182/20090706-3-fr-2004.00256 · Cited by 384
Human-competitive results produced by genetic programming
Koza, J. R. (2010) · Genetic Programming and Evolvable Machines · doi:10.1007/s10710-010-9112-3 · Cited by 321
A˚ström, K. J., & Kumar, P. R. (2014) · Automatica · doi:10.1016/j.automatica.2013.10.012 · Cited by 304
(1997) · Elsevier eBooks · doi:10.1016/b978-0-12-526430-3.x5000-4 · Cited by 290
Performance and gain and phase margins of well-known PID tuning formulas
Ho, W. K., Gan, O. P., Tay, E. B., & Ang, E. L. (1996) · IEEE Transactions on Control Systems Technology · doi:10.1109/87.508897 · Cited by 283
Direct Nonlinear Control Design: The Virtual Reference Feedback Tuning (VRFT) Approach
Campi, M. C., & Savaresi, S. M. (2006) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2005.861689 · Cited by 281
Astrom, K. J. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13721 · Cited by 274
Relay feedback auto-tuning of process controllers — a tutorial review
Hang, C. C., Astrom, K. J., & Wang, Q. G. (2002) · Journal of Process Control · doi:10.1016/s0959-1524(01)00025-7 · Cited by 272
Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.28 · Cited by 270
Neath, M. J., Swain, A. K., Madawala, U. K., & Thrimawithana, D. J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262953 · Cited by 256
Kreysing, M., Keil, L., Lanzmich, S., & Braun, D. (2015) · Nature Chemistry · doi:10.1038/nchem.2155 · Cited by 169
Xu, L. (2014) · Applied Mathematics and Computation · doi:10.1016/j.amc.2014.02.087 · Cited by 139
Active Tendon Control of Torsionally Irregular Structures under Near-Fault Ground Motion Excitation
Nigdeli, S. M., & Boduroğlu, M. H. (2013) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12046 · Cited by 77
Reinforcement learning-based adaptive PID controller for DPS
Lee, D., Lee, S. J., & Yim, S. C. (2020) · Ocean Engineering · doi:10.1016/j.oceaneng.2020.108053 · Cited by 80
Adesanya, M. A., Obasekore, H., Rabiu, A., Na, W.-H., Ogunlowo, Q. O., Akpenpuun, T. D., Kim, M.-H., Kim, H.-T., Kang, B.-Y., & Lee, H.-W. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.124126 · Cited by 72
Metadata
- Authors
- Ziegler, J. G., & Nichols, N. B.
- Venue
- Journal of Fluids Engineering
- Publisher
- ASME International
- Published
- 1942-11-01
- Volume
- 64
- Issue
- 8
- Pages
- 759-765
- ISSN
- 0097-6822 (ISSN-L)
- OpenAlex
- W2980070341
- Cited by
- 5,212
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.