CoChat

Comparison of histometric data obtained by optical coherence tomography and routine histology

Open access
Gambichler, Thilo, Boms, Stefanie, Stücker, Markus, Kreuter, Alexander, Sand, Michael, Moussa, Georg, Altmeyer, Peter, Hoffmann, Klaus · 2005 · Journal of Biomedical Optics
Cited by 40

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

There is a lack of systematic investigations comparing optical coherence tomography (OCT) with histology. OCT assessments were performed on the upper back of 16 healthy subjects. Epidermis thickness (ET) was assessed using three methods: first, peak-to-valley analysis of the A-scan (ET-OCT-V); second, manual measurements in the OCT images (ET-OCT-M); third, light microscopic determination using routine histology (ET-Histo). The relationship between the different methods was assessed by means of the Pearson correlation procedure and Bland and Altman plots. We observed a strong correlation between ET-Histo (79.4+/-21.9 microm) and ET-OCT-V (79.2+/-15.5 microm, r=0.77) and ET-OCT-M (82.9+/-15.8 microm, r=0.75), respectively. Bland and Altman plots revealed a bias of -0.19 microm (95% limits of agreement: -27.94 microm to 27.56 microm) for ET-OCT-V versus ET-Histo and a bias of 3.44 microm (95% limits of agreement: -24.9 microm to 31.78 microm) for ET-OCT-M versus ET-Histo. Despite the strong correlation and low bias observed, the 95% limits of agreement demonstrated an unsatisfactory numerical agreement between the two OCT methods and routine histology indicating that these methods cannot be employed interchangeably. Regarding practicability, precision, and indication spectrum, ET-OCT-V and ET-OCT-M are of different clinical value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.2039086

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 25

  1. Gambichler, 2003, Trends Clin. Exp. Dermatol., 1, 32
  2. 10.1111/j.0022-202X.2004.23404.x · DOI · Paper page
  3. 10.1364/OPEX.12.003236 · DOI
  4. de Boer, 1998, Opt. Express, 3, 212, 10.1364/OE.3.000212 · DOI · Paper page
  5. Hyle Park, 2003, Opt. Express, 11, 782, 10.1364/OE.11.000782 · DOI
  6. 10.1038/nbt892 · DOI · Paper page
  7. 10.1117/1.1629679 · DOI
  8. 10.1023/A:1016634505173 · doi:10.1023/a:1016634505173
  9. Welzel, 2003, Arch. Dermatol. Res., 295, 50, 10.1007/s00403-003-0390-y · DOI · Paper page
  10. Therkildsen, 1998, Skin Res. Technol., 4, 174, 10.1111/j.1600-0846.1998.tb00106.x · DOI
  11. 10.1117/1.1648647 · doi:10.1117/1.1648647
  12. 10.1016/0925-5273(93)90083-W · doi:10.1016/0925-5273(93)90083-w
  13. Welzel, 2001, Skin Res. Technol., 7, 1, 10.1034/j.1600-0846.2001.007001001.x · DOI · Paper page
  14. Bland, 1999, Stat. Methods Med. Res., 8, 135, 10.1177/096228029900800204 · DOI · Paper page
  15. 10.1111/j.1365-2133.2004.05810.x · DOI
  16. T. Gambichler, S. Boms, M. Stücker et al. , “Epidermal thickness assessed by optical coherence tomography and routine histology,” J. Eur. Acad. Dermatol. Venereol (in press).
  17. Vogt, 2003, Biomed. Tech., 48, 116, 10.1515/bmte.2003.48.5.116 · DOI · Paper page
  18. Bland, 1996, Br. Med. J., 313, 744, 10.1136/bmj.313.7059.744 · DOI · Paper page
  19. Fruhstorfer, 2000, Clin. Anat., 13, 429, 10.1002/1098-2353(2000)13:6<429::AID-CA6>3.0.CO;2-5 · DOI
  20. 10.1117/1.1645795 · DOI · Paper page
  21. 10.1046/j.1523-1747.1999.00795.x · doi:10.1046/j.1523-1747.1999.00795.x
  22. 10.1007/s005210170005 · doi:10.1007/s005210170005
  23. Sauermann, 2002, Skin Res. Technol., 8, 52, 10.1046/j.0909-752x.2001.10297.x · DOI · Paper page
  24. Meijer, 2003, Thromb. Haemostasis, 90, 555, 10.1055/s-0037-1613419 · DOI
  25. 10.1364/OPEX.12.005760 · DOI

Cited by

Metadata

Authors
Gambichler, T., Boms, S., Stücker, M., Kreuter, A., Sand, M., Moussa, G., Altmeyer, P., & Hoffmann, K.
Venue
Journal of Biomedical Optics
Published
2005
Volume
10
Issue
4
Pages
044008
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2121906317
Cited by
40
References
2
FWCI
4.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.