Comparison of histometric data obtained by optical coherence tomography and routine histology
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
There is a lack of systematic investigations comparing optical coherence tomography (OCT) with histology. OCT assessments were performed on the upper back of 16 healthy subjects. Epidermis thickness (ET) was assessed using three methods: first, peak-to-valley analysis of the A-scan (ET-OCT-V); second, manual measurements in the OCT images (ET-OCT-M); third, light microscopic determination using routine histology (ET-Histo). The relationship between the different methods was assessed by means of the Pearson correlation procedure and Bland and Altman plots. We observed a strong correlation between ET-Histo (79.4+/-21.9 microm) and ET-OCT-V (79.2+/-15.5 microm, r=0.77) and ET-OCT-M (82.9+/-15.8 microm, r=0.75), respectively. Bland and Altman plots revealed a bias of -0.19 microm (95% limits of agreement: -27.94 microm to 27.56 microm) for ET-OCT-V versus ET-Histo and a bias of 3.44 microm (95% limits of agreement: -24.9 microm to 31.78 microm) for ET-OCT-M versus ET-Histo. Despite the strong correlation and low bias observed, the 95% limits of agreement demonstrated an unsatisfactory numerical agreement between the two OCT methods and routine histology indicating that these methods cannot be employed interchangeably. Regarding practicability, precision, and indication spectrum, ET-OCT-V and ET-OCT-M are of different clinical value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Sandby-Møller, J., Poulsen, T., & Wulf, H. C. (2003) · Acta Dermato-Venereologica · doi:10.1080/00015550310015419 · Cited by 737
Research works printed but not linked: 25
- Gambichler, 2003, Trends Clin. Exp. Dermatol., 1, 32
- 10.1111/j.0022-202X.2004.23404.x · DOI · Paper page
- 10.1364/OPEX.12.003236 · DOI
- de Boer, 1998, Opt. Express, 3, 212, 10.1364/OE.3.000212 · DOI · Paper page
- Hyle Park, 2003, Opt. Express, 11, 782, 10.1364/OE.11.000782 · DOI
- 10.1038/nbt892 · DOI · Paper page
- 10.1117/1.1629679 · DOI
- 10.1023/A:1016634505173 · doi:10.1023/a:1016634505173
- Welzel, 2003, Arch. Dermatol. Res., 295, 50, 10.1007/s00403-003-0390-y · DOI · Paper page
- Therkildsen, 1998, Skin Res. Technol., 4, 174, 10.1111/j.1600-0846.1998.tb00106.x · DOI
- 10.1117/1.1648647 · doi:10.1117/1.1648647
- 10.1016/0925-5273(93)90083-W · doi:10.1016/0925-5273(93)90083-w
- Welzel, 2001, Skin Res. Technol., 7, 1, 10.1034/j.1600-0846.2001.007001001.x · DOI · Paper page
- Bland, 1999, Stat. Methods Med. Res., 8, 135, 10.1177/096228029900800204 · DOI · Paper page
- 10.1111/j.1365-2133.2004.05810.x · DOI
- T. Gambichler, S. Boms, M. Stücker et al. , “Epidermal thickness assessed by optical coherence tomography and routine histology,” J. Eur. Acad. Dermatol. Venereol (in press).
- Vogt, 2003, Biomed. Tech., 48, 116, 10.1515/bmte.2003.48.5.116 · DOI · Paper page
- Bland, 1996, Br. Med. J., 313, 744, 10.1136/bmj.313.7059.744 · DOI · Paper page
- Fruhstorfer, 2000, Clin. Anat., 13, 429, 10.1002/1098-2353(2000)13:6<429::AID-CA6>3.0.CO;2-5 · DOI
- 10.1117/1.1645795 · DOI · Paper page
- 10.1046/j.1523-1747.1999.00795.x · doi:10.1046/j.1523-1747.1999.00795.x
- 10.1007/s005210170005 · doi:10.1007/s005210170005
- Sauermann, 2002, Skin Res. Technol., 8, 52, 10.1046/j.0909-752x.2001.10297.x · DOI · Paper page
- Meijer, 2003, Thromb. Haemostasis, 90, 555, 10.1055/s-0037-1613419 · DOI
- 10.1364/OPEX.12.005760 · DOI
Cited by
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Self-citationOptical coherence tomography in dermatology: technical and clinical aspects
Gambichler, T., Jaedicke, V., & Terras, S. (2011) · Archives of Dermatological Research · doi:10.1007/s00403-011-1152-x · Cited by 240
“mal thickness as confirmed in several correlation studies [29, 30, 74].”
BackgroundSelf-citationMorphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography
Mogensen, M., Morsy, H. A., Thrane, L., & Jemec, G. B. E. (2008) · Dermatology · doi:10.1159/000118508 · Cited by 183
Advances in optical coherence tomography in dermatology—a review
Olsen, J., Holmes, J., & Jemec, G. B. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.040901 · Cited by 165
Silver, R., Helms, A., Fu, W., Wang, H., Diaconu, D., Loyd, C. M., Rollins, A. M., & Ward, N. L. (2012) · Skin Research and Technology · doi:10.1111/j.1600-0846.2011.00558.x · Cited by 16
Metadata
- Authors
- Gambichler, T., Boms, S., Stücker, M., Kreuter, A., Sand, M., Moussa, G., Altmeyer, P., & Hoffmann, K.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2005
- Volume
- 10
- Issue
- 4
- Pages
- 044008
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2121906317
- Cited by
- 40
- References
- 2
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.