The DOI matches its Crossref record.
Influence of oxygen saturation on the optical scattering properties of human red blood cells in the spectral range 250 to 2000 nm
Open accessAbstract
The intrinsic optical parameters absorption coefficient mu(a), scattering coefficient micros, anisotropy factor g, and effective scattering coefficient micros were determined for human red blood cell (RBC) suspensions of hematocrit 33.2% dependent on the oxygen saturation (SAT O(2)) in the wavelength range 250 to 2,000 nm, including the range above 1,100 nm, about which there are no data available in the literature. Integrating sphere measurements of light transmittance and reflectance in combination with inverse Monte Carlo simulation were carried out for SAT O(2) levels of 100 and 0%. In the wavelength range up to 1,200 nm, the absorption behavior is determined by the hemoglobin absorption. The spectral range above the cells' absorption shows no dependence on SAT O(2) and approximates the absorption of water with values 20 to 30% below the respective values for water. Parameters micros and g are significantly influenced by the SAT O(2)-induced absorption changes. Above 600 nm, micros decreases continuously from values of 85 mm(-1) to values of 30 mm(-1) at 2,000 nm. The anisotropy factor shows a slight decrease with wavelengths above 600 nm. In the spectral regions of 1,450 and 1,900 nm where water has local absorption maxima, g shows a significant decrease down to 0.85, whereas micros increases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Deep tissue multiphoton microscopy using longer wavelength excitation
Kobat, D., Durst, M. E., Nishimura, N., Wong, A. W., Schaffer, C. B., & Xu, C. (2009) · Optics Express · doi:10.1364/oe.17.013354 · Cited by 574
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“For decades, near-infrared imaging in the 700–900-nm NIR-I window has been pursued for in vivo biomedical imaging 6 so as to benefit from the suppressed light scattering by tissues compared to visible light as well as lower absorption by haemoglobin 7 .”
A literature review and novel theoretical approach on the optical properties of whole blood
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J. (2014) · Lasers in Medical Science · doi:10.1007/s10103-013-1446-7 · Cited by 459
Wilson, R. H., Nadeau, K. P., Jaworski, F. B., Tromberg, B. J., & Durkin, A. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.030901 · Cited by 415
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Recent Progress in NIR-II Contrast Agent for Biological Imaging
Cao, J., Zhu, B., Zheng, K., He, S., Meng, L., Song, J., & Yang, H. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00487 · Cited by 313
Xu, J., Gulzar, A., Yang, P., Bi, H., Yang, D., Gai, S., He, F., Lin, J., Xing, B., & Jin, D. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.11.014 · Cited by 310
Liang, Y.-J., Liu, F., Chen, Y.-F., Wang, X.-J., Sun, K.-N., & Pan, Z. (2016) · Light: Science & Applications · doi:10.1038/lsa.2016.124 · Cited by 261
Ajmal, Boonya-Ananta, T., Rodriguez, A. J., Du Le, V. N., & Ramella-Roman, J. C. (2021) · Biomedical Optics Express · doi:10.1364/boe.439893 · Cited by 79
Boonya-ananta, T., Rodriguez, A. J., Ajmal, A., Du Le, V. N., Hansen, A. K., Hutcheson, J. D., & Ramella-Roman, J. C. (2021) · Scientific Reports · doi:10.1038/s41598-021-82124-4 · Cited by 70
Metadata
- Authors
- Friebel, M., Helfmann, J., Netz, U., & Meinke, M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2009
- Volume
- 14
- Issue
- 3
- Pages
- 034001
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2097105186
- Cited by
- 182
- References
- 0
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.