Fiber Bragg grating-based sensor for monitoring respiration and heart activity during magnetic resonance imaging examinations
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We present a fiber-optic sensor for monitoring respiration and heart activity designed to operate in the magnetic resonance imaging (MRI) environment. The sensor employs a Plexiglas springboard, which converts movements of the patient's body lying on the board (i.e., lung- and heart-induced vibrations) to strain, where a fiber Bragg grating attached to the board is used to measure this strain. Experimental studies are carried out during thoracic spine MRI examinations. The presence of the metal-free sensor construction in the MRI environment does not pose a threat to the patient and has no influence over the quality of imaging, and the signal is identical to that obtained without any electromagnetic interference. The results show that the sensor is able to accurately reflect the ballistocardiographic signal, enabling determinations of the respiration rate (RR) and heart rate (HR). The data delivered by the sensor are normally distributed on the Bland-Altman plot for the characteristic point determination and exhibit clear dependence on the RR and HR values for the RR and HR determinations, respectively. Measurement accuracies are better than 7% of the average values, and thus, with further development, the sensor will be implemented in routine MRI examinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“In both cases, the reference RR trace and that obtained on the basis of the sensor signal are of similar shape, and therefore the Bland–Altman plot was used for quantitatively assessing the sensor’s RR measurement capability.(48,49) In this graphical method, the differences between the two techniques (i.”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Pittig, A., Arch, J. J., Lam, C. W. R., & Craske, M. G. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2012.10.012 · Cited by 255
Meuret, A. E., Rosenfield, D., Seidel, A., Bhaskara, L., & Hofmann, S. G. (2010) · Journal of Consulting and Clinical Psychology · doi:10.1037/a0019552 · Cited by 161
Meuret, A. E., Ritz, T., Wilhelm, F. H., & Roth, W. T. (2005) · Clinical Psychology Review · doi:10.1016/j.cpr.2005.01.002 · Cited by 84 · cited 1×
“Hyperventilation has numerous theoretical and empirical links to anxiety, panic, and fear episodes.(6,7) This phenomenon was investigated in order to understand psychological and physiological mechanisms connected with hyperventilation that cause and maintain anxiety.”
Background
Cited by
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Fiber Bragg Gratings for Medical Applications and Future Challenges: A Review
Lo Presti, D., Massaroni, C., Jorge Leitão, C. S., De Fátima Domingues, M., Sypabekova, M., Barrera, D., Floris, I., Massari, L., Oddo, C. M., Sales, S., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3019138 · Cited by 377
Thermally drawn advanced functional fibers: New frontier of flexible electronics
Yan, W., Dong, C., Xiang, Y., Jiang, S., Leber, A., Loke, G., Xu, W., Hou, C., Zhou, S., Chen, M., et al. (2020) · Materials Today · doi:10.1016/j.mattod.2019.11.006 · Cited by 263
Roriz, P., Carvalho, L., Frazão, O., Santos, J. L., & Simões, J. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.01.054 · Cited by 226
“Dziuda et al., 2013a; Dziuda et al., 2013b obtained results, using an optical strain sensor based on a fibre Bragg grating, for monitoring respiration and cardiac activity of a patient, during a magnetic resonance imaging (MRI) survey.”
MethodOptical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview
Taffoni, F., Formica, D., Saccomandi, P., Pino, G., & Schena, E. (2013) · Sensors · doi:10.3390/s131014105 · Cited by 221
“, 2013 [9] FBG Respiratory/heart rate (HR)/(RR) Respiratory and cardiac monitoring Accuracy RR: 1.”
BackgroundWearable System Based on Flexible FBG for Respiratory and Cardiac Monitoring
Lo Presti, D., Massaroni, C., D'Abbraccio, J., Massari, L., Caponero, M., Longo, U. G., Formica, D., Oddo, C. M., & Schena, E. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2916320 · Cited by 219
“, Plexiglas board [20]) or taped on textiles to develop smart systems (e.”
Ballistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 216
“[93] Peak Detector 8 M, 4 F MRI 60 Min HR, RR”
BackgroundOptical Fibre Pressure Sensors in Medical Applications
Poeggel, S., Tosi, D., Duraibabu, D., Leen, G., McGrath, D., & Lewis, E. (2015) · Sensors · doi:10.3390/s150717115 · Cited by 208
“A wide variety of ex vivo or in vitro pressure measurements in other physiological locations have been successfully performed, including oesophageal pressure [192] and lung pressure during respiration [193].”
BackgroundA Machine Learning Approach to Improve Contactless Heart Rate Monitoring Using a Webcam
Monkaresi, H., Calvo, R. A., & Yan, H. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2291900 · Cited by 179
Medical Smart Textiles Based on Fiber Optic Technology: An Overview
Massaroni, C., Saccomandi, P., & Schena, E. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6020204 · Cited by 172
“An FBG sensor was attached with epoxy adhesive [60].”
MethodA Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring
Fajkus, M., Nedoma, J., Martinek, R., Vasinek, V., Nazeran, H., & Siska, P. (2017) · Sensors · doi:10.3390/s17010111 · Cited by 168
“FBG sensors were used to monitor the cardiac activity and respiration [4,6,8,10,13,17,19,28,30].”
MethodSmart textile for respiratory monitoring and thoraco-abdominal motion pattern evaluation
Massaroni, C., Venanzi, C., Silvatti, A. P., Lo Presti, D., Saccomandi, P., Formica, D., Giurazza, F., Caponero, M. A., & Schena, E. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201700263 · Cited by 139
Jiang, B., Bi, Z., Hao, Z., Yuan, Q., Feng, D., Zhou, K., Zhang, L., Gan, X., & Zhao, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.05.024 · Cited by 133
Fiber Bragg Grating Sensors for Cardiorespiratory Monitoring: A Review
Massaroni, C., Zaltieri, M., Lo Presti, D., Nicolo, A., Tosi, D., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2988692 · Cited by 128
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103
Pang, Y.-N., Liu, B., Liu, J., Wan, S. P., Wu, T., He, X., Yuan, J., Zhou, X., Long, K., & Wu, Q. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3032646 · Cited by 67
“Fiber Bragg Grating (FBG) is also applied to monitor respiration, by utilizing its sensing property to strain, curvature, temperature, and relative humidity [12-15].”
Metadata
- Authors
- Dziuda, Ł., Skibniewski, F. W., Krej, M., & Baran, P. M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-05-22
- Volume
- 18
- Issue
- 5
- Pages
- 057006
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2152584058
- Cited by
- 121
- References
- 7
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.