High-sensitivity, real-time, ratiometric imaging of surface-enhanced Raman scattering nanoparticles with a clinically translatable Raman endoscope device
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Topical application and quantification of targeted, surface-enhanced Raman scattering (SERS) nanoparticles offer a new technique that has the potential for early detection of epithelial cancers of hollow organs. Although less toxic than intravenous delivery, the additional washing required to remove unbound nanoparticles cannot necessarily eliminate nonspecific pooling. Therefore, we developed a real-time, ratiometric imaging technique to determine the relative concentrations of at least two spectrally unique nanoparticle types, where one serves as a nontargeted control. This approach improves the specific detection of bound, targeted nanoparticles by adjusting for working distance and for any nonspecific accumulation following washing. We engineered hardware and software to acquire SERS signals and ratios in real time and display them via a graphical user interface. We report quantitative, ratiometric imaging with nanoparticles at pM and sub-pM concentrations and at varying working distances, up to 50 mm. Additionally, we discuss optimization of a Raman endoscope by evaluating the effects of lens material and fiber coating on background noise, and theoretically modeling and simulating collection efficiency at various working distances. This work will enable the development of a clinically translatable, noncontact Raman endoscope capable of rapidly scanning large, topographically complex tissue surfaces for small and otherwise hard to detect lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201 · cited 1×
“In previous utilizations of SERS nanoparticles, no additional flavors were used as a control to account for nonspecific signal.(13,14,31,36) To address the last two limitations, our clinically oriented strategy uses a ratiometric approach for quantifying at least two SERS nanoparticle flavors, where one is used as a n…”
MethodSurface-Enhanced Raman Spectroscopy
Haynes, C. L., McFarland, A. D., & Van Duyne, R. P. (2005) · Analytical Chemistry · doi:10.1021/ac053456d · Cited by 1,144
Zavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
Self-citationA Raman-based endoscopic strategy for multiplexed molecular imaging
Zavaleta, C. L., Garai, E., Liu, J. T. C., Sensarn, S., Mandella, M. J., Van de Sompel, D., Friedland, S., Van Dam, J., Contag, C. H., & Gambhir, S. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211309110 · Cited by 238
Self-citationThe Fate and Toxicity of Raman-Active Silica-Gold Nanoparticles in Mice
Thakor, A. S., Luong, R., Paulmurugan, R., Lin, F. I., Kempen, P., Zavaleta, C., Chu, P., Massoud, T. F., Sinclair, R., & Gambhir, S. S. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001963 · Cited by 159
Self-citationSpectral Analysis of Multiplex Raman Probe Signatures
Lutz, B. R., Dentinger, C. E., Nguyen, L. N., Sun, L., Zhang, J., Allen, A. N., Chan, S., & Knudsen, B. S. (2008) · ACS Nano · doi:10.1021/nn800243g · Cited by 135 · cited 1×
“A leastsquares algorithm has been previously described to extract signals by fitting a set of known Raman and background references to a measurement.(35) It would be advantageous to obtain a large data set of the colon wall, for example, prior to the topical application of the SERS nanoparticles in order to optimally…”
MethodRaman's “Effect” on Molecular Imaging
Zavaleta, C. L., Kircher, M. F., & Gambhir, S. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.087775 · Cited by 88
Self-citationA Hybrid Least Squares and Principal Component Analysis Algorithm for Raman Spectroscopy
Van de Sompel, D., Garai, E., Zavaleta, C., & Gambhir, S. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038850 · Cited by 39
Self-citation
Cited by
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Itoh, T., Procházka, M., Dong, Z.-C., Ji, W., Yamamoto, Y. S., Zhang, Y., & Ozaki, Y. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00316 · Cited by 571
Surface-enhanced resonance Raman scattering nanostars for high-precision cancer imaging
Harmsen, S., Huang, R., Wall, M. A., Karabeber, H., Samii, J. M., Spaliviero, M., White, J. R., Monette, S., O’Connor, R., Pitter, K. L., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010633 · Cited by 296
“New Raman imaging devices are currently being developed that also enable endoscopic detection (14, 40), detection in deeper tissues (41), and even tomographic Raman imaging (13) (fig.”
BackgroundA targeted approach to cancer imaging and therapy
Li, C. (2014) · Nature Materials · doi:10.1038/nmat3877 · Cited by 268
Metadata
- Authors
- Garai, E., Sensarn, S., Zavaleta, C. L., Van de Sompel, D., Loewke, N. O., Mandella, M. J., Gambhir, S. S., & Contag, C. H.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-09-05
- Volume
- 18
- Issue
- 09
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W1989137548
- Cited by
- 70
- References
- 8
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.