Diffuse optical characterization of collagen absorption from 500 to 1700 nm
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Reduction in scattering, high absorption, and spectral features of tissue constituents above 1000 nm could help in gaining higher spatial resolution, penetration depth, and specificity for in vivo studies, opening possibilities of near-infrared diffuse optics in tissue diagnosis. We present the characterization of collagen absorption over a broadband range (500 to 1700 nm) and compare it with spectra presented in the literature. Measurements were performed using a time-domain diffuse optical technique. The spectrum was extracted by carefully accounting for various spectral distortion effects, due to sample and system properties. The contribution of several tissue constituents (water, lipid, collagen, oxy, and deoxy-hemoglobin) to the absorption properties of a collagen-rich in vivo bone location, such as radius distal in the 500- to 1700-nm wavelength region, is also discussed, suggesting bone diagnostics as a potential area of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Collagen density promotes mammary tumor initiation and progression
Provenzano, P. P., Inman, D. R., Eliceiri, K. W., Knittel, J. G., Yan, L., Rueden, C. T., White, J. G., & Keely, P. J. (2008) · BMC Medicine · doi:10.1186/1741-7015-6-11 · Cited by 1,361
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Dynamic Cell Seeding of Polymer Scaffolds for Cartilage Tissue Engineering
Vunjak‐Novakovic, G., Obradovic, B., Martin, I., Bursac, P. M., Langer, R., & Freed, L. E. (1998) · Biotechnology Progress · doi:10.1021/bp970120j · Cited by 551 · cited 1×
“For collagen, the high absorption in the SWIR region(9) can be exploited to investigate its dynamics of growth in studies related to tissue culture or engineering.(17,18) To our knowledge, the first characterization of collagen absorption in the 600- to 1100-nm range was reported by Taroni et al.”
BackgroundThe role of DXA bone density scans in the diagnosis and treatment of osteoporosis
Blake, G. M., & Fogelman, I. (2007) · Postgraduate Medical Journal · doi:10.1136/pgmj.2007.057505 · Cited by 532 · cited 1×
“Importantly, radius distal is one among the locations considered for bone mineral assessment by DXA scans and is rich of collagen, which can be of interest for diagnosing bone pathologies.(34) Figure 4 depicts the calculated broadband (500 to 1700 nm) weighted spectra of major tissue constituents, namely oxy-hemoglobi…”
BackgroundContini, D., Martelli, F., & Zaccanti, G. (1997) · Applied Optics · doi:10.1364/ao.36.004587 · Cited by 460
Wilson, R. H., Nadeau, K. P., Jaworski, F. B., Tromberg, B. J., & Durkin, A. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.030901 · Cited by 415
Alerstam, E., Svensson, T., & Andersson-Engels, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041496 · Cited by 407
Predicting response to breast cancer neoadjuvant chemotherapy using diffuse optical spectroscopy
Cerussi, A. E., Hsiang, D. J. B., Shah, N. S., Mehta, R. S., Durkin, A. F., Butler, J., & Tromberg, B. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0611058104 · Cited by 295
Near-infrared Absorption Property of Biological Soft Tissue Constituents
Tsai, C.-L., Chen, J.-C., & Wang, W. (2001) · Tamkang University Institutional Repository (TKUIR) · Cited by 251
Performance assessment of photon migration instruments: the MEDPHOT protocol
Pifferi, A., Torricelli, A., Bassi, A., Taroni, P., Cubeddu, R., Wabnitz, H., Grosenick, D., Möller, M., Macdonald, R., Swartling, J., et al. (2005) · Applied Optics · doi:10.1364/ao.44.002104 · Cited by 245
Self-citationNew frontiers in time-domain diffuse optics, a review
Pifferi, A., Contini, D., Mora, A. D., Farina, A., Spinelli, L., & Torricelli, A. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091310 · Cited by 245
Self-citationMartelli, F., Del Bianco, S., Ismaelli, A., & Zaccanti, G. (2009) · Florence Research (University of Florence) · doi:10.1117/3.824746 · Cited by 238
Nachabe, R., Hendriks, B. H., Lucassen, G. W., van der Voort, M., Evers, D. J., Rutgers, E. J., Peeters, M.-J. V., Van der Hage, J. A., Oldenburg, H. S., Ruers, T. J., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3611010 · Cited by 161
Optical biopsy of bone tissue: a step toward the diagnosis of bone pathologies
Pifferi, A., Torricelli, A., Taroni, P., Bassi, A., Chikoidze, E., Giambattistelli, E., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1691029 · Cited by 137
Self-citationExperimental test of theoretical models for time-resolved reflectance
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A. M., & Valentini, G. (1996) · Medical Physics · doi:10.1118/1.597739 · Cited by 123 · cited 1×
“Importantly, to further avoid these random fluctuations from affecting the absorption spectrum, we smoothened the scattering spectrum and fixed its value when fitting to estimate the absorption spectrum, as described in detail elsewhere.(30,31) We compared our data with collagen absorption spectra reported in the lite…”
ResultSelf-citationThere’s plenty of light at the bottom: statistics of photon penetration depth in random media
Martelli, F., Binzoni, T., Pifferi, A., Spinelli, L., Farina, A., & Torricelli, A. M. (2016) · Scientific Reports · doi:10.1038/srep27057 · Cited by 111
Self-citationClinical trial of time-resolved scanning optical mammography at 4 wavelengths between 683 and 975 nm
Taroni, P., Danesini, G. M., Torricelli, A. M., Pifferi, A., Spinelli, L., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1695561 · Cited by 110
Self-citationBroadband (600–1350 nm) Time-Resolved Diffuse Optical Spectrometer for Clinical Use
Sekar, S. K. V., Mora, A. D. D., Bargigia, I., Martinenghi, E., Lindner, C., Farzam, P., Pagliazzi, M., Durduran, T., Taroni, P., Pifferi, A., et al. (2015) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2015.2506613 · Cited by 107 · cited 1×
“The instrument performances were rigorously validated elsewhere over the two spectral ranges R1 1⁄4 500 to 1100 nm and R2 1⁄4 1100 to 1700 nm.(10,20) In particular, the accuracy and linearity tests were performed applying the MEDPHOT protocol,(29)”
MethodSelf-citationBond‐selective imaging of deep tissue through the optical window between 1600 and 1850 nm
Wang, P., Wang, H., Sturek, M., & Cheng, J. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201100102 · Cited by 90 · cited 1×
“was reported using photoacoustics at SWIR wavelengths as compared to the near-infrared region.(15,16) For collagen, the high absorption in the SWIR region(9) can be exploited to investigate its dynamics of growth in studies related to tissue culture or engineering.”
Pifferi, A., Torricelli, A. M., Taroni, P., Comelli, D., Bassi, A. L., & Cubeddu, R. (2007) · Review of Scientific Instruments · doi:10.1063/1.2735567 · Cited by 86
Self-citationMartinenghi, E., Sieno, L. D., Contini, D., Sanzaro, M., Pifferi, A., & Mora, A. D. D. (2016) · Review of Scientific Instruments · doi:10.1063/1.4954968 · Cited by 83
Self-citationDiffuse optical spectroscopy of breast tissue extended to 1100 nm
Taroni, P., Bassi, A. L., Comelli, D., Farina, A., Cubeddu, R., & Pifferi, A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3251051 · Cited by 81 · cited 3×
“Works by Taroni et al. 11 and Provenzano et al. 12 showed that collagen density in breast tissues correlates with breast density and accordingly with the risk of breast cancer.”
MethodSelf-citationMapping lipid and collagen by multispectral photoacoustic imaging of chemical bond vibration
Wang, P., Wang, P., Wang, H.-W., & Cheng, J.-X. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.096010 · Cited by 72 · cited 1×
“was reported using photoacoustics at SWIR wavelengths as compared to the near-infrared region.(15,16) For collagen, the high absorption in the SWIR region(9) can be exploited to investigate its dynamics of growth in studies related to tissue culture or engineering.”
Tosi, A., Della Frera, A., Bahgat Shehata, A., & Scarcella, C. (2012) · Review of Scientific Instruments · doi:10.1063/1.3675579 · Cited by 69
Self-citationBargigia, I., Tosi, A., Shehata, A. B., Frera, A. D., Farina, A., Bassi, A. L., Taroni, P., Mora, A. D. D., Zappa, F., Cubeddu, R., et al. (2012) · Applied Spectroscopy · doi:10.1366/11-06461 · Cited by 64 · cited 3×
“The instrument performances were rigorously validated elsewhere over the two spectral ranges R1 1⁄4 500 to 1100 nm and R2 1⁄4 1100 to 1700 nm.(10,20) In particular, the accuracy and linearity tests were performed applying the MEDPHOT protocol,(29)”
MethodSelf-citationKhoptyar, D., Subash, A. A., Johansson, S., Saleem, M. S., Sparén, A., Johansson, J., & Andersson‐Engels, S. (2013) · Optics Express · doi:10.1364/oe.21.020941 · Cited by 47
A Physical Model of Human Skin and Its Application for Search and Rescue
Nunez, A. S. (2012) · Cited by 31
Bandpass Effects in Time-Resolved Diffuse Spectroscopy
Farina, A., Bassi, A. L., Pifferi, A., Taroni, P., Comelli, D., Spinelli, L., & Cubeddu, R. (2009) · Applied Spectroscopy · doi:10.1366/000370209787169795 · Cited by 25 · cited 1×
“Since negligible differences were observed upon changing the fitting range, we can exclude possible bandwidth distortion, which are more pronounced for wider fitting ranges on the trailing edge of the photon temporal distribution.(27) The instrument performances were rigorously validated elsewhere over the two spectra…”
BackgroundSelf-citationSekar, S. K. V., Farina, A., Martinenghi, E., Mora, A. D. D., Taroni, P., Pifferi, A., Negredo, E., Puig, J., Escrig, R., Rosales, Q., et al. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2183724 · Cited by 16 · cited 1×
“The radius distal location was chosen, as it has thin superficial muscle, giving easy access to bone probing in an in vivo measurement.(14)”
MethodSelf-citationSekar, S. K. V., Farina, A., Martinenghi, E., Mora, A. D. D., Taroni, P., Pifferi, A., Durduran, T., Pagliazzi, M., Lindner, C., Farzam, P., et al. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2183835 · Cited by 16
Self-citationIn vivo Time domain Broadband (600 -1200 nm) Diffuse Optical Characterization of Human Bone
Sekar, S. K. V., Mora, A. D. D., Martinenghi, E., Taroni, P., Pifferi, A., Farina, A., Puig, J., Negredo, E., Lindner, C., Pagliazzi, M., et al. (2016) · Biomedical optics · doi:10.1364/cancer.2016.jtu3a.32 · Cited by 5
Self-citation
Cited by
Broadband (550–1350 nm) diffuse optical characterization of thyroid chromophores
Konugolu Venkata Sekar, S., Farina, A., Dalla Mora, A., Lindner, C., Pagliazzi, M., Mora, M., Aranda, G., Dehghani, H., Durduran, T., Taroni, P., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-27684-8 · Cited by 549
Self-citationRegensburger, A. P., Fonteyne, L. M., Jüngert, J., Wagner, A. L., Gerhalter, T., Nagel, A. M., Heiss, R., Flenkenthaler, F., Qurashi, M., Neurath, M. F., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0669-y · Cited by 203
Non-invasive investigation of adipose tissue by time domain diffuse optical spectroscopy
Lanka, P., Segala, A., Farina, A., Konugolu Venkata Sekar, S., Nisoli, E., Valerio, A., Taroni, P., Cubeddu, R., & Pifferi, A. (2020) · Biomedical Optics Express · doi:10.1364/boe.391028 · Cited by 39
Self-citation
Metadata
- Authors
- Sekar, S. K. V., Bargigia, I., Mora, A. D., Taroni, P., Ruggeri, A., Tosi, A., Pifferi, A., & Farina, A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2017-01-31
- Volume
- 22
- Issue
- 1
- Pages
- 015006
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2585344219
- Cited by
- 168
- References
- 33
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.