Lorusso, Gian Francesco, Sutani, Takumichi, Rutigliani, Vito, van Roey, Frieda, Moussa, Alain, Charley, Anne-Laure, Mack, Chris, Naulleau, Patrick, Perera, Chami, Constantoudis, Vassilios, Ikota, Masami, Ishimoto, Toru, Koshihara, Shunsuke·2018·Journal of Micro/Nanopatterning, Materials, and Metrology

Abstract

As semiconductor technology keeps moving forward, undeterred by the many challenges ahead, one specific deliverable is capturing the attention of many experts in the field: line width roughness (LWR) specifications are expected to be <2 nm in the near term, and to drop below 1 nm in just a few years. This is a daunting challenge and engineers throughout the industry are trying to meet these targets using every means at their disposal. However, although current efforts are surely admirable, we believe they are not enough. The fact is that a specification has a meaning only if there is an agreed methodology to verify if the criterion is met or not. Such standardization is critical in any field of science and technology and the question that we need to ask ourselves today is whether we have a standardized LWR metrology or not. In other words, if a single reference sample were provided, would everyone measuring it get reasonably comparable results? We came to realize that this is not the case and that the observed spread in the results throughout the industry is quite large. In our opinion, this makes the comparison of LWR data among institutions, or to a specification, very difficult. We report the spread of measured LWR data across the semiconductor industry. We investigate the impact of image acquisition, measurement algorithm, and frequency analysis parameters on LWR metrology. We review critically some of the International Technology Roadmap for Semiconductors (ITRS) metrology guidelines [such as measurement box length >2 μm and the need to correct for scanning electron microscope (SEM) noise]. We compare the SEM roughness results to AFM measurements. Finally, we propose a standardized LWR measurement protocol—the imec roughness protocol—intended to ensure that every time LWR measurements are compared (from various sources or to specifications), the comparison is sensible and sound. We deeply believe that the industry is at a point where it is imperative to guarantee that when talking about a critical parameter such as LWR, everyone speaks the same language, which is not currently the case.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.jmm.17.4.041009

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Standardized SEM collection parameters aim to minimize the impact of the electron beam on photoresist samples and enable results to be compared between different systems.

    “Efforts have led to standardized SEM collection parameters, which aim to minimize the impact of the electron beam on photoresist samples and enable results to be compared between different systems 83 .”

    From Extreme ultraviolet lithography (2024) · cites this paper as [83]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Lorusso, G. F., Sutani, T., Rutigliani, V., van Roey, F., Moussa, A., Charley, A.-L., Mack, C., Naulleau, P., Perera, C., Constantoudis, V., Ikota, M., Ishimoto, T., & Koshihara, S.
Affiliations
  • IMEC (BE)
  • Hitachi High-Tech (Japan) (JP)
  • IMEC
  • Fractilia, LLC
  • Lawrence Berkeley National Laboratory (US)
  • EUV Labs (Russia) (RU)
  • Institute of Nanoscience and Nanotechnology
  • Hitachi (Japan) (JP)
Venue
Journal of Micro/Nanopatterning, Materials, and Metrology
Published
2018-09-12
Volume
17
Issue
04
Pages
1-8
ISSN
2708-8340 (ISSN-L)
OpenAlex
W2891757578
Cited by
59
References
12
Citations by year
2026: 2 · 2025: 7 · 2024: 9 · 2023: 8 · 2022: 6 · 2021: 7 · 2020: 7 · 2019: 11 · 2018: 2
FWCI
2.58
Type
journal article
Language
en
Open access
Locations
  • Journal of Micro/Nanopatterning Materials and Metrology (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Photolithography Techniques
  • Physical Sciences › Physics and Astronomy › Instrumentation › Surface Roughness and Optical Measurements
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
Keywords
line width roughness, repeatability, image acquisition parameters, measurement algorithm, frequency analysis, semiconductor lithography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review