CoChat

Towards integrated superconducting detectors on lithium niobate waveguides

Open access

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Abstract

Superconducting detectors are now well-established tools for low-light optics, and in particular quantum optics, boasting high-eciency, fast response and low noise. Similarly, lithium niobate is an important platform for integrated optics given its high second-order nonlinearity, used for high-speed electro-optic modulation and polarization conversion, as well as frequency conversion and sources of quantum light. Combining these technologies addresses the requirements for a single platform capable of generating, manipulating and measuring quantum light in many degrees of freedom, in a compact and potentially scalable manner. We will report on progress integrating tungsten transition-edge sensors (TESs) and amorphous tungsten silicide superconducting nanowire single-photon detectors (SNSPDs) on titanium in-di‚used lithium niobate waveguides. ‘e travelling-wave design couples the evanescent €eld from the waveguides into the superconducting absorber. We will report on simulations and measurements of the absorption, which we can characterize at room temperature prior to cooling down the devices. Independently, we show how the detectors respond to ƒood illumination, normally incident on the devices, demonstrating their functionality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/12.2273388

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 21

Metadata

Authors
Höpker, J. P., Bartnick, M., Meyer-Scott, E., Thiele, F., Meier, T., Bartley, T., Krapick, S., Montaut, N. M., Santandrea, M., Herrmann, H., Lengeling, S., Ricken, R., Quiring, V., Lita, A. E., Verma, V. B., Gerrits, T., Nam, S. W., & Silberhorn, C.
Affiliations
  • Paderborn University (DE)
  • National Institute of Standards and Technology (US)
Venue
Quantum Photonic Devices
Publisher
SPIE
Published
2017-08-29
Pages
7
OpenAlex
W2748798971
Cited by
20
References
48
Citations by year
2024: 4 · 2023: 2 · 2022: 1 · 2021: 4 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 1
FWCI
13.11
Type
conference paper
Language
en
Open access
Locations
  • Quantum Photonic Devices (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Deutsche Forschungsgemeinschaft (SFB/TRR142, TRR 142)
  • National Institute of Standards and Technology
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
Keywords
superconducting detectors, lithium niobate waveguides, transition edge sensors, superconducting nanowire single-photon detectors, integrated photonics, quantum light, evanescent coupling, room-temperature absorption

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.