Diffuse optical tomography of breast cancer during neoadjuvant chemotherapy: A case study with comparison to MRI
Abstract
We employ diffuse optical tomography (DOT) to track treatment progress in a female subject presenting with locally advanced invasive carcinoma of the breast during neoadjuvant chemotherapy. Three‐dimensional images of total hemoglobin concentration and scattering identified the tumor. Our measurements reveal tumor shrinkage during the course of chemotherapy, in reasonable agreement with magnetic resonance images of the same subject. A decrease in total hemoglobin concentration contrast between tumor and normal tissue was also observed over time. The results demonstrate the potential of DOT for measuring physiological parameters of breast lesions during chemotherapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/b978-0-12-374701-3.x5001-7 · Cited by 2,447
Effect of preoperative chemotherapy on the outcome of women with operable breast cancer.
Fisher, B., Bryant, J., Wolmark, N., Mamounas, E., Brown, A., Fisher, E. R., Wickerham, D. L., Begovic, M., DeCillis, A., Robidoux, A., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.8.2672 · Cited by 2,165
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationThe composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Imaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Non-Invasive In Vivo Characterization of Breast Tumors Using Photon Migration Spectroscopy
Tromberg, B. J., Shah, N., Lanning, R., Cerussi, A., Espinoza, J., Pham, T., Svaasand, L., & Butler, J. (2000) · Neoplasia · doi:10.1038/sj.neo.7900082 · Cited by 687
(2003) · CRC Press eBooks · doi:10.1201/9780203008997 · Cited by 605
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Boetes, C., Mus, R. D., Holland, R., Barentsz, J. O., Strijk, S. P., Wobbes, T., Hendriks, J. H., & Ruys, S. H. (1995) · Radiology · doi:10.1148/radiology.197.3.7480749 · Cited by 519
Scattering and absorption of turbid materials determined from reflection measurements 1: Theory
Groenhuis, R. A. J., Ferwerda, H. A., & Ten Bosch, J. J. (1983) · Applied Optics · doi:10.1364/ao.22.002456 · Cited by 490
The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
Boas, D. A., Gaudette, T., Strangman, G., Cheng, X., Marota, J. J. A., & Mandeville, J. B. (2001) · NeuroImage · doi:10.1006/nimg.2000.0674 · Cited by 459
Culver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Self-citationImplicit and explicit dosimetry in photodynamic therapy: a New paradigm
Wilson, B. C., Patterson, M. S., & Lilge, L. (1997) · Lasers in Medical Science · doi:10.1007/bf02765099 · Cited by 411
Durduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Self-citationFrequency-domain techniques enhance optical mammography: Initial clinical results
Franceschini, M. A., Moesta, K. T., Fantini, S., Gaida, G., Gratton, E., Jess, H., Mantulin, W. W., Seeber, M., Schlag, P. M., & Kaschke, M. F. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6468 · Cited by 334
Photon-measurement density functions Part 2: Finite-element-method calculations
Arridge, S. R., & Schweiger, M. (1995) · Applied Optics · doi:10.1364/ao.34.008026 · Cited by 310
Self-citationBulk optical properties of healthy female breast tissue
Durduran, T., Choe, R., Culver, J. P., Zubkov, L., Holboke, M. J., Giammarco, J., Chance, B., & Yodh, A. G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/302 · Cited by 291
Self-citationStaging of symptomatic primary breast cancer with MR imaging.
Mumtaz, H., Hall-Craggs, M. A., Davidson, T., Walmsley, K., Thurell, W., Kissin, M. W., & Taylor, I. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.169.2.9242745 · Cited by 291
Bevilacqua, F., Berger, A. J., Cerussi, A. E., Jakubowski, D., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Dehghani, H., Pogue, B. W., Poplack, S. P., & Paulsen, K. D. (2003) · Applied Optics · doi:10.1364/ao.42.000135 · Cited by 274
Average soft-tissue and bone models for use in radiation dosimetry
White, D. R., Woodard, H. Q., & Hammond, S. M. (1987) · The British Journal of Radiology · doi:10.1259/0007-1285-60-717-907 · Cited by 241
Jakubowski, D. B., Cerussi, A. E., Bevilacqua, F., Shah, N., Hsiang, D., Butler, J., & Tromberg, B. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629681 · Cited by 206
Grosenick, D., Moesta, K. T., Wabnitz, H., Mucke, J., Stroszczynski, C., Macdonald, R., Schlag, P. M., & Rinneberg, H. (2003) · Applied Optics · doi:10.1364/ao.42.003170 · Cited by 202
Lee, N. A., Rusinek, H., Weinreb, J., Chandra, R., Toth, H., Singer, C., & Newstead, G. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.168.2.9016235 · Cited by 174
Vaupel, P. W., & Höckel, M. (2000) · International Journal of Oncology · doi:10.3892/ijo.17.5.869 · Cited by 165
Treatment-Induced Changes in Tumor Oxygenation Predict Photodynamic Therapy Outcome
Wang, H.-W., Putt, M. E., Emanuele, M. J., Shin, D. B., Glatstein, E., Yodh, A. G., & Busch, T. M. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-3632 · Cited by 161
Self-citationHueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/304 · Cited by 158
Self-citationZhu, Q., Huang, M., Chen, N., Zarfos, K. A., Jagjivan, B., Kane, M., Hedge, P., & Kurtzman, S. H. (2003) · Neoplasia · doi:10.1016/s1476-5586(03)80040-4 · Cited by 155
Diffusion equation derived from space-time transport equation
Furutsu, K. (1980) · Journal of the Optical Society of America · doi:10.1364/josa.70.000360 · Cited by 115
Three-dimensional optical tomographic imaging of breast in a human subject
Jiang, H., Xu, Y., Iftimia, N. V., et al. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974928 · Cited by 113
Does the photon-diffusion coefficient depend on absorption?
Durduran, T., Yodh, A. G., Chance, B., et al. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.003358 · Cited by 109
Self-citationVaupel, P. W., Mayer, A., Briest, S., & Höckel, M. (2003) · PubMed · Cited by 100
Physiological and Pathological Factors of Human Breast Disease That Can Influence Optical Diagnosisa
Thomsen, S., & Tatman, D. (1998) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1998.tb08197.x · Cited by 93
Four-wavelength time-resolved optical mammography in the 680 980-nm range
Pifferi, A., Taroni, P., Torricelli, A. M., et al. (2003) · Optics Letters · doi:10.1364/ol.28.001138 · Cited by 77
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
PET regularization by envelope guided conjugate gradients
Kaufman, L., & Neumaier, A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.500147 · Cited by 45
Functional Imaging with Diusing Light
Yodh, A. G., & Boas, D. A. (2014) · CRC Press eBooks · doi:10.1201/b17289-15 · Cited by 39
Self-citationWolf, U., Wolf, M., Choi, J. H., Paunescu, L. A., Safonova, L. P., Michalos, A., & Gratton, E. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0205-0_37 · Cited by 38
Gasparini, G., Biganzoli, E. M., Bonoldi, E., Morabito, A., Fanelli, M., & Boracchi, P. (2001) · Breast Cancer Research and Treatment · doi:10.1023/a:1006476401801 · Cited by 37
Cited by
The physics and applications of random lasers
Wiersma, D. S. (2008) · Nature Physics · doi:10.1038/nphys971 · Cited by 1,555
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationFLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Metadata
- Authors
- Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., Chance, B., Rosen, M. A., & Yodh, A. G.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2005-03-29
- Volume
- 32
- Issue
- 4
- Pages
- 1128-1139
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2090967583
- Cited by
- 295
- References
- 39
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.