The DOI matches its Crossref record.
Radiation dose enhancement in tumors with iodine
Abstract
The loading of tissue with iodine can result in the enhancement of the radiation dose absorbed from low‐energy x‐ray or gamma ray sources. We have explored the potential of this phenomenon for radiation therapy. We have demonstrated the effect of iodine concentration and radiation quality on this dose enhancement in lymphocytes, we have calculated the effect of such enhancement on depth dose distributions in the brain, we have estimated the iodine content in two human brain tumors during computerized tomography (CT) scans, we have studied the dispersion of the iodine contrast media after direct injection into rabbit tumors, and we have demonstrated that the combination of x‐ray and contrast media injection is far more effective than either agent alone in causing the regression of mouse tumors. These results suggest that there may be a therapeutic advantage from loading tumors with iodine and treating them with low‐energy photons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The use of gold nanoparticles to enhance radiotherapy in mice
Hainfeld, J. F., Slatkin, D. N., & Smilowitz, H. M. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/n03 · Cited by 1,638
Gold nanoparticles as novel agents for cancer therapy
Jain, S., Hirst, D. G., & O'Sullivan, J. M. (2012) · The British Journal of Radiology · doi:10.1259/bjr/59448833 · Cited by 1,059
Radiotherapy enhancement with gold nanoparticles
Hainfeld, J. F., Dilmanian, F. A., Slatkin, D. N., & Smilowitz, H. M. (2008) · Journal of Pharmacy and Pharmacology · doi:10.1211/jpp.60.8.0005 · Cited by 733
Gold Nanoparticles as Radiation Sensitizers in Cancer Therapy
Chithrani, D. B., Jelveh, S., Jalali, F., van Prooijen, M., Allen, C., Bristow, R. G., Hill, R. P., & Jaffray, D. A. (2010) · Radiation Research · doi:10.1667/rr1984.1 · Cited by 669
Gold Nanoparticle Imaging and Radiotherapy of Brain Tumors in Mice
Hainfeld, J. F., Smilowitz, H. M., O‘Connor, M. J., Dilmanian, F. A., & Slatkin, D. N. (2013) · Nanomedicine · doi:10.2217/nnm.12.165 · Cited by 430
Cho, S. H. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/15/n01 · Cited by 419
Enhancement of radiation effects by gold nanoparticles for superficial radiation therapy
Rahman, W. N., Bishara, N., Ackerly, T., He, C. F., Jackson, P., Wong, C., Davidson, R., & Geso, M. (2009) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2009.01.014 · Cited by 369
Leung, M. K. K., Chow, J. C. L., Chithrani, B. D., Lee, M. J. G., Oms, B., & Jaffray, D. A. (2011) · Medical Physics · doi:10.1118/1.3539623 · Cited by 265
Roadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
Schuemann, J., Berbeco, R., Chithrani, D. B., Cho, S. H., Kumar, R., McMahon, S. J., Sridhar, S., & Krishnan, S. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.09.032 · Cited by 253
Application of High-Z Nanoparticles to Enhance Current Radiotherapy Treatment
Jackson, N., Cecchi, D., Beckham, W., & Chithrani, D. B. (2024) · Molecules · doi:10.3390/molecules29112438 · Cited by 52
Babaye Abdollahi, B., Ghorbani, M., Hamishehkar, H., Malekzadeh, R., & Farajollahi, A. (2023) · BioImpacts · doi:10.34172/bi.2022.23682 · Cited by 29
Metadata
- Authors
- Mello, R. S., Callisen, H., Winter, J., Kagan, A. R., & Norman, A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 10
- Issue
- 1
- Pages
- 75-78
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2052745473
- Cited by
- 167
- References
- 0
- FWCI
- 0.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.