Acoustic noise during functional magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Functional magnetic resonance imaging (fMRI) enables sites of brain activation to be localized in human subjects. For studies of the auditory system, acoustic noise generated during fMRI can interfere with assessments of this activation by introducing uncontrolled extraneous sounds. As a first step toward reducing the noise during fMRI, this paper describes the temporal and spectral characteristics of the noise present under typical fMRI study conditions for two imagers with different static magnetic field strengths. Peak noise levels were 123 and 138 dB re 20 μPa in a 1.5-tesla (T) and a 3-T imager, respectively. The noise spectrum (calculated over a 10-ms window coinciding with the highest-amplitude noise) showed a prominent maximum at 1 kHz for the 1.5-T imager (115 dB SPL) and at 1.4 kHz for the 3-T imager (131 dB SPL). The frequency content and timing of the most intense noise components indicated that the noise was primarily attributable to the readout gradients in the imaging pulse sequence. The noise persisted above background levels for 300–500 ms after gradient activity ceased, indicating that resonating structures in the imager or noise reverberating in the imager room were also factors. The gradient noise waveform was highly repeatable. In addition, the coolant pump for the imager’s permanent magnet and the room air-handling system were sources of ongoing noise lower in both level and frequency than gradient coil noise. Knowledge of the sources and characteristics of the noise enabled the examination of general approaches to noise control that could be applied to reduce the unwanted noise during fMRI sessions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Discrete-Time Signal Processing
Oppenheim, A. V., & Schafer, R. W. (1989) · Cited by 12,673
Pashler, H. (1997) · doi:10.7551/mitpress/5677.001.0001 · Cited by 1,607
?sparse? temporal sampling in auditory fMRI
Hall, D. A., Haggard, M. P., Akeroyd, M. A., Palmer, A. R., Summerfield, A. Q., Elliott, M. R., Gurney, E. M., & Bowtell, R. W. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:3<213::aid-hbm5>3.0.co;2-n · Cited by 869 · cited 1×
“…have been shown to reduce the influence of the noise on brain activity, these modified paradigms compromise either the temporal resolution of measurements or the efficiency with which data are acquired (Edmister et al., 1999; Hall et al., 1999; see Melcher et al., 1999 for a discussion).”
BackgroundElliott, S. J., & Nelson, P. A. (1993) · IEEE Signal Processing Magazine · doi:10.1109/79.248551 · Cited by 846 · cited 2×
“…is, however, an inherent delay due to processing time that causes the noise and antinoise to become out of phase as frequency increases; hence, with increasing frequency, the antinoise produces a diminishing reduction and eventually an amplification of the noise (e.g., Elliott and Nelson, 1993).”
Improved auditory cortex imaging using clustered volume acquisitions
Edmister, W. B., Talavage, T. M., Ledden, P. J., & Weisskoff, R. M. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)7:2<89::aid-hbm2>3.0.co;2-n · Cited by 341 · cited 3×
“, 1999), and the noise itself can produce brain activity that is not related to the intended stimuli (Bandettini et al., 1998; Ulmer et al., 1998; Talavage et al., 1999; Edmister et al., 1999).”
BackgroundFunctional MRI of brain activation induced by scanner acoustic noise
Bandettini, P. A., Jesmanowicz, A., van Kylen, J., Birn, R. M., & Hyde, J. S. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390311 · Cited by 235 · cited 2×
“, 1999), and the noise itself can produce brain activity that is not related to the intended stimuli (Bandettini et al., 1998; Ulmer et al., 1998; Talavage et al., 1999; Edmister et al., 1999).”
BackgroundTonotopy in human auditory cortex examined with functional magnetic resonance imaging
Wessinger, C. M., Buonocore, M. H., Kussmaul, C. L., & Mangun, G. R. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:1<18::aid-hbm3>3.0.co;2-q · Cited by 200 · cited 3×
“, 1999) or qualitative descriptions of the noise (Wessinger et al., 1997; Ulmer et al., 1998).”
BackgroundPotential hearing loss resulting from MR imaging.
Brummett, R. E., Talbot, J. M., & Charuhas, P. (1988) · Radiology · doi:10.1148/radiology.169.2.3175004 · Cited by 169 · cited 1×
“Because most of these reports were, at least in part, motivated by concerns that exposures to high-level imaging noise might damage hearing (e.g., Brummett et al., 1988), previous studies of the noise during EPIbased fMRI sought data that are relevant for estimating damage risk criteria, such as…”
BackgroundModulation of auditory and visual cortex by selective attention is modality-dependent
Woodruff, P. W. R., Benson, R. R., Bandettini, P. A., Kwong, K. K., Howard, R. J., Talavage, T., Belliveau, J., & Rosen, B. R. (1996) · NeuroReport · doi:10.1097/00001756-199608120-00007 · Cited by 148
Eden, G. F., Joseph, J. E., Brown, H. E., Brown, C. P., & Zeffiro, T. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<13::aid-mrm4>3.0.co;2-t · Cited by 147 · cited 2×
“background noise can mask the stimuli (Shah et al., 1999; Eden et al., 1999), and the noise itself can produce brain activity that is not related to the intended stimuli (Bandettini et al.”
Background
Cited by
Pavlovian conditioning-induced hallucinations result from overweighting of perceptual priors
Powers, A. R., Mathys, C., & Corlett, P. R. (2017) · Science · doi:10.1126/science.aan3458 · Cited by 684
Penagos, H., Melcher, J. R., & Oxenham, A. J. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.0383-04.2004 · Cited by 266
Self-citationMagnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000073442.88269.c9 · Cited by 212
“These other factors are wide ranging and run from the use of specialized compounds to resist gradient motion, through to the use of acoustic-deadening tiles in the scanner room.(31) Nevertheless, theoretically, Lorentz’s Law predicts larger forces on gradients per unit gradient current and thus the gradients become in…”
BackgroundDeep Learning of Static and Dynamic Brain Functional Networks for Early MCI Detection
Kam, T.-E., Zhang, H., Jiao, Z., & Shen, D. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2928790 · Cited by 187
“BFNs have higher level of noise compared to the structural MRI [26]; 2) BFNs are sitting in a manifold when represented by adjacency matrices [27], making it difficult to define a “local pattern” for convolutional operation; 3) The temporal pattern of dBFNs cannot be simply learned, as different subjects have differen…”
BackgroundHarms, M. P., & Melcher, J. R. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1433 · Cited by 182
“During both threshold determination and functional imaging, there was an on-going low-frequency background noise produced primarily by the pump for the liquid helium (used to supercool the magnet coils) (Ravicz et al. 2000).”
BackgroundSelf-citationAcoustic noise and functional magnetic resonance imaging: Current strategies and future prospects
Amaro, E., Williams, S. C. R., Shergill, S. S., Fu, C. H. Y., MacSweeney, M., Picchioni, M. M., Brammer, M. J., & McGuire, P. K. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10186 · Cited by 175
“Vibration can be attenuated by using special cushioning, thereby reducing if not eliminating noise conduction through bone (16).”
BackgroundMethodInfluentialNeural Processing of Auditory Looming in the Human Brain
Seifritz, E., Neuhoff, J. G., Bilecen, D., Scheffler, K., Mustovic, H., Schächinger, H., Elefante, R., & Di Salle, F. (2002) · Current Biology · doi:10.1016/s0960-9822(02)01356-8 · Cited by 164
Rinne, T., Degerman, A., & Alho, K. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.017 · Cited by 161
“Previously, frontal lobe contribution to the electric MMN has been suggested based on EEG (Baldeweg et al., 2002; Giard et al., 1990; Rinne et al., 2000) and intra-cranial recordings (Liasis et al., 2001).”
BackgroundSensory prediction errors in the continuum of psychosis
Randeniya, R., Oestreich, L. K. L., & Garrido, M. I. (2018) · Schizophrenia Research · doi:10.1016/j.schres.2017.04.019 · Cited by 78
Metadata
- Authors
- Ravicz, M. E., Melcher, J. R., & Kiang, N. Y.-S.
- Venue
- The Journal of the Acoustical Society of America
- Publisher
- Acoustical Society of America (ASA)
- Published
- 2000-10-01
- Volume
- 108
- Issue
- 4
- Pages
- 1683-1696
- ISSN
- 0001-4966 (ISSN-L)
- 1520-8524
- OpenAlex
- W2077961543
- Cited by
- 177
- References
- 23
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.