CoChat

Training-Induced Changes in the Respiratory Compensation Point, Deoxyhemoglobin Break Point, and Maximal Lactate Steady State: Evidence of Equivalence

Inglis, Erin Calaine, Iannetta, Danilo, Keir, Daniel A., Murias, Juan M. · 2020 · International Journal of Sports Physiology and Performance

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

Purpose To evaluate whether the coherence in the oxygen uptake (V˙O2) associated with the respiratory compensation point (RCP), near-infrared spectroscopy-derived muscle deoxyhemoglobin ([HHb]) break point ([HHb]BP), and maximal lactate steady state (MLSS) would persist at the midpoint and endpoint of a 7-month training and racing season. Methods Eight amateur male cyclists were tested in 3 separate phases over the course of a cycling season (PRE, MID, and POST). Testing at each phase included a ramp-incremental test to exhaustion to determine RCP and [HHb]BP. The PRE and POST phases also included constant power output rides to determine MLSS. Results Compared with PRE, V˙O2 at both RCP and [HHb]BP was greater at MID (delta: RCP 0.23 [0.14] L·min-1, [HHb]BP 0.33 [0.17] L·min-1) and POST (delta: RCP 0.21 [0.12], [HHb]BP 0.30 [0.14] L·min-1) (P .05). PRE-MID and PRE-POST changes in V˙O2 associated with RCP, [HHb]BP, and MLSS were strongly correlated (range: r = .85-.90) and demonstrated low mean bias (range = -.09 to .12 L·min-1). Conclusions At all measured time points, V˙O2 at RCP, [HHb]BP, and MLSS were not different. Irrespective of phase comparison, direction, or magnitude of V˙O2 changes, intraindividual changes between each index were strongly related, indicating that interindividual differences were reflected in the group mean response and that their interrelationships are beyond coincidental.

Overview

Integrity signals

Registry

Crossref · 10.1123/ijspp.2019-0046

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 36

  1. Beneke, 2003, Methodological aspects of maximal lactate steady state—implications for performance testing, Eur J Appl Physiol, 89, 95, 10.1007/s00421-002-0783-1 · DOI · Paper page
  2. Bellotti, 2013, Determination of maximal lactate steady state in healthy adults: can NIRS help?, Med Sci Sports Exerc, 45, 1208, 10.1249/mss.0b013e3182828ab2 · DOI · Paper page
  3. Billat, 2003, The concept of maximal lactate steady state, Sports Med, 33, 407, 10.2165/00007256-200333060-00003 · DOI · Paper page
  4. Boone, 2016, The interrelationship between muscle oxygenation, muscle activation, and pulmonary oxygen uptake to incremental ramp exercise: influence of aerobic fitness, Appl Physiol Nutr Metab, 41, 55, 10.1139/apnm-2015-0261 · DOI · Paper page
  5. Iannetta, 2017, The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains, J Sci Med Sport, 20, 873, 10.1016/j.jsams.2017.01.237 · DOI · Paper page
  6. Keir, 2019, Response, Med Sci Sport Exerc, 51, 830, 10.1249/mss.0000000000001851 · DOI
  7. Caen, 2018, Exercise thresholds on trial: are they really equivalent?, Med Sci Sports Exerc, 50, 1277, 10.1249/mss.0000000000001547 · DOI · Paper page
  8. Iannetta, 2018, An equation to predict the maximal lactate steady state from ramp incremental exercise test data in cycling, J Sci Med Sport, 21, 1274, 10.1016/j.jsams.2018.05.004 · DOI · Paper page
  9. Leo, 2017, The respiratory compensation point is not a valid surrogate for critical power, Med Sci Sports Exerc, 49, 1452, 10.1249/mss.0000000000001226 · DOI · Paper page
  10. Inglis, 2017, The plateau in the NIRS-derived [HHb] signal near the end of a ramp incremental test does not indicate the upper limit of O2 extraction in the vastus lateralis, Am J Physiol Regul Integr Comp Physiol, 313, R723, 10.1152/ajpregu.00261.2017 · DOI · Paper page
  11. Beaver, 1986, A new method for detecting anaerobic threshold by gas exchange, J Appl Physiol, 60, 2020, 10.1152/jappl.1986.60.6.2020 · DOI · Paper page
  12. Wang, 2017, Tracking changes in the upper boundary of the heavy-intensity exercise domain: end-test power versus respiratory compensation point, Kinesiology, 49, 15, 10.26582/k.49.1.13 · DOI
  13. Keir, 2016, Influence of muscle metabolic heterogenity in determining the VO2p kinetic response to ramp-incremental exercise, J Appl Physiol, 120, 503, 10.1152/japplphysiol.00804.2015 · DOI · Paper page
  14. Pringle, 2002, Maximal lactate steady state, critical power and EMG during cycling, Eur J Appl Physiol, 88, 214, 10.1007/s00421-002-0703-4 · DOI · Paper page
  15. Mattioni Maturana, 2018, Critical power: how different protocols and models affect its determination, J Sci Med Sport, 21, 742, 10.1016/j.jsams.2017.11.015 · DOI · Paper page
  16. Fontana, 2015, Determination of respiratory point compensation in healthy adults: can non-invasive near-infrared spectroscopy help?, J Sci Med Sport, 18, 590, 10.1016/j.jsams.2014.07.016 · DOI · Paper page
  17. Craig, 2015, Considerations for identifying the boundaries of sustainable performance, Med Sci Sports Exerc, 47, 1997, 10.1249/mss.0000000000000676 · DOI · Paper page
  18. Keir, 2015, Response, Med Sci Sports Exerc, 47, 1998, 10.1249/mss.0000000000000677 · DOI
  19. McKay, 2009, Effect of short-term high-intensity interval training vs continuous training on O2 uptake kinetics, muscle deoxygenation, and exercise performance, J Appl Physiol, 107, 128, 10.1152/japplphysiol.90828.2008 · DOI · Paper page
  20. Keir, 2015, Exercise intensity thresholds: identifying the boundaries of sustainable performance, Med Sci Sports Exerc, 47, 1932, 10.1249/mss.0000000000000613 · DOI · Paper page
  21. Prieur, 2005, Effect of endurance training on the V˙O2-work rate relationship in normoxia and hypoxia, Med Sci Sports Exerc, 37, 664, 10.1249/01.mss.0000159140.11938.97 · DOI
  22. Boone, 2019, The question should be: is HHbBP equivalent to RCP?, Med Sci Sports Exerc, 51, 829, 10.1249/mss.0000000000001850 · DOI
  23. Keir, 2018, The respiratory compensation point/Deoxy-BP are valid surrogates for critical power/maximum lactate steady state, Med Sci Sports Exerc, 50, 2375, 10.1249/mss.0000000000001698 · DOI · Paper page
  24. Keir, 2018, Using ramp-incremental V˙O2 responses for constant-intensity exercise selection, Appl Physiol Nutr Metab, 43, 882, 10.1139/apnm-2017-0826 · DOI · Paper page
  25. Murias, 2013, Sex-related differences in muscle deoxygenation during ramp incremental exercise, Respir Physiol Neurobiol, 189, 530, 10.1016/j.resp.2013.08.011 · DOI · Paper page
  26. Broxterman, 2015, The relationship between critical speed and the respiratory compensation point: coincidence or equivalence, Eur J Sport Sci, 15, 631, 10.1080/17461391.2014.966764 · DOI · Paper page
  27. Mattioni Maturana, 2016, Can measures of critical power precisely estimate the maximal metabolic steady-state?, Appl Physiol Nutr Metab, 41, 1197, 10.1139/apnm-2016-0248 · DOI · Paper page
  28. Iannetta, 2018, Metabolic and performance-related consequences of exercising at and slightly above MLSS, Scand J Med Sci Sports, 28, 2481, 10.1111/sms.13280 · DOI · Paper page
  29. Bishop, 1998, The critical power function is dependent on the duration of predictive tests chosen, Int J Sports Med, 19, 125, 10.1055/s-2007-971894 · DOI · Paper page
  30. Iannetta, 2017, Quadriceps muscles O2 extraction and EMG breakpoints during a ramp incremental test, Front Physiol, 8, 686, 10.3389/fphys.2017.00686 · DOI · Paper page
  31. Scheuermann, 1998, Attenuated respiratory compensation during rapidly incremented ramp exercise, Respir Physiol, 114, 227, 10.1016/s0034-5687(98)00097-8 · DOI
  32. Boone, 2008, The VO2 response to submaximal ramp cycle exercise: influence of ramp slope and training status, Respir Physiol Neurobiol, 161, 291, 10.1016/j.resp.2008.03.008 · DOI
  33. Spencer, 2012, Characterizing the profile of muscle deoxygenation during ramp incremental exercise in young men, Eur J Appl Physiol, 112, 3349, 10.1007/s00421-012-2323-y · DOI · Paper page
  34. Hauser, 2013, Reliability of maximal lactate-steady-state, Int J Sports Med, 34, 196
  35. Barker, 2006, Human critical power-oxygen uptake relationship at different pedalling frequencies, Exp Physiol, 91, 621, 10.1113/expphysiol.2005.032789 · DOI · Paper page
  36. Broxterman, 2018, The respiratory compensation point and the deoxygenation break point are not valid surrogates for critical power and maximum lactate steady state, Med Sci Sports Exerc, 50, 2379, 10.1249/mss.0000000000001699 · DOI · Paper page

Cited by

See all 28

Metadata

Authors
Inglis, E. C., Iannetta, D., Keir, D. A., & Murias, J. M.
Venue
International Journal of Sports Physiology and Performance
Published
2020-01-01
Volume
15
Issue
1
Pages
119-125
ISSN
  • 1555-0265 (ISSN-L)
  • 1555-0273
OpenAlex
W2943802763
Cited by
21
References
36
Citations by year
2026: 2 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 1
FWCI
3.54
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Sports Physiology and Performance (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Research Information System (Università degli Studi di Brescia) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
Keywords
respiratory compensation point, maximal lactate steady state, training-induced changes, oxygen consumption, cycling, near-infrared spectroscopy, muscle oxygenation, cardiorespiratory fitness, training season

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.