Training-Induced Changes in the Respiratory Compensation Point, Deoxyhemoglobin Break Point, and Maximal Lactate Steady State: Evidence of Equivalence
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Purpose To evaluate whether the coherence in the oxygen uptake (V˙O2) associated with the respiratory compensation point (RCP), near-infrared spectroscopy-derived muscle deoxyhemoglobin ([HHb]) break point ([HHb]BP), and maximal lactate steady state (MLSS) would persist at the midpoint and endpoint of a 7-month training and racing season. Methods Eight amateur male cyclists were tested in 3 separate phases over the course of a cycling season (PRE, MID, and POST). Testing at each phase included a ramp-incremental test to exhaustion to determine RCP and [HHb]BP. The PRE and POST phases also included constant power output rides to determine MLSS. Results Compared with PRE, V˙O2 at both RCP and [HHb]BP was greater at MID (delta: RCP 0.23 [0.14] L·min-1, [HHb]BP 0.33 [0.17] L·min-1) and POST (delta: RCP 0.21 [0.12], [HHb]BP 0.30 [0.14] L·min-1) (P .05). PRE-MID and PRE-POST changes in V˙O2 associated with RCP, [HHb]BP, and MLSS were strongly correlated (range: r = .85-.90) and demonstrated low mean bias (range = -.09 to .12 L·min-1). Conclusions At all measured time points, V˙O2 at RCP, [HHb]BP, and MLSS were not different. Irrespective of phase comparison, direction, or magnitude of V˙O2 changes, intraindividual changes between each index were strongly related, indicating that interindividual differences were reflected in the group mean response and that their interrelationships are beyond coincidental.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“With regard to the agreement between exercise intensity thresholds in the incremental tests, the response of HHb during the incremental test is typically assessed using continuous protocols with no recovery period between the stages (Belloti et al. 2013; Boone et al. 2015; Inglis et al. 2020).”
From Comparison of NIRS-derived [HHb] breakpoints and concordance with lactate thresholds during speed- and slope-based incremental running tests (2026) · cites this paper as Inglis et al. 2020
In the citing paper
“Multiple studies have validated various stationary NIRS sensors with each of the physiological and performance markers outlined above, during various modes of exercise (12, 17, 22, 29–31).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [30]
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Billat, V. L., Sirvent, P., Py, G., Koralsztein, J.-P., & Mercier, J. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00003 · Cited by 397
Methodological aspects of maximal lactate steady state-implications for performance testing
Beneke, R. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0783-1 · Cited by 264
Maximal lactate steady state, critical power and EMG during cycling
Pringle, J., & Jones, A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0703-4 · Cited by 224
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Self-citationMcKay, B. R., Paterson, D. H., & Kowalchuk, J. M. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90828.2008 · Cited by 163
The Critical Power Function is Dependent on the Duration of the Predictive Exercise Tests Chosen
Bishop, D., Jenkins, D., & Howard, A. (1998) · International Journal of Sports Medicine · doi:10.1055/s-2007-971894 · Cited by 143
Human critical power–oxygen uptake relationship at different pedalling frequencies
Barker, T., Poole, D. C., Noble, M. L., & Barstow, T. J. (2006) · Experimental Physiology · doi:10.1113/expphysiol.2005.032789 · Cited by 106
Using ramp-incremental V̇O2 responses for constant-intensity exercise selection
Keir, D. A., Paterson, D. H., Kowalchuk, J. M., & Murias, J. M. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0826 · Cited by 97
Self-citationCharacterizing the profile of muscle deoxygenation during ramp incremental exercise in young men
Spencer, M. D., Murias, J. M., & Paterson, D. H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2323-y · Cited by 96
Self-citation
Research works printed but not linked: 36
- Beneke, 2003, Methodological aspects of maximal lactate steady state—implications for performance testing, Eur J Appl Physiol, 89, 95, 10.1007/s00421-002-0783-1 · DOI · Paper page
- Bellotti, 2013, Determination of maximal lactate steady state in healthy adults: can NIRS help?, Med Sci Sports Exerc, 45, 1208, 10.1249/mss.0b013e3182828ab2 · DOI · Paper page
- Billat, 2003, The concept of maximal lactate steady state, Sports Med, 33, 407, 10.2165/00007256-200333060-00003 · DOI · Paper page
- Boone, 2016, The interrelationship between muscle oxygenation, muscle activation, and pulmonary oxygen uptake to incremental ramp exercise: influence of aerobic fitness, Appl Physiol Nutr Metab, 41, 55, 10.1139/apnm-2015-0261 · DOI · Paper page
- Iannetta, 2017, The near-infrared spectroscopy-derived deoxygenated haemoglobin breaking-point is a repeatable measure that demarcates exercise intensity domains, J Sci Med Sport, 20, 873, 10.1016/j.jsams.2017.01.237 · DOI · Paper page
- Keir, 2019, Response, Med Sci Sport Exerc, 51, 830, 10.1249/mss.0000000000001851 · DOI
- Caen, 2018, Exercise thresholds on trial: are they really equivalent?, Med Sci Sports Exerc, 50, 1277, 10.1249/mss.0000000000001547 · DOI · Paper page
- Iannetta, 2018, An equation to predict the maximal lactate steady state from ramp incremental exercise test data in cycling, J Sci Med Sport, 21, 1274, 10.1016/j.jsams.2018.05.004 · DOI · Paper page
- Leo, 2017, The respiratory compensation point is not a valid surrogate for critical power, Med Sci Sports Exerc, 49, 1452, 10.1249/mss.0000000000001226 · DOI · Paper page
- Inglis, 2017, The plateau in the NIRS-derived [HHb] signal near the end of a ramp incremental test does not indicate the upper limit of O2 extraction in the vastus lateralis, Am J Physiol Regul Integr Comp Physiol, 313, R723, 10.1152/ajpregu.00261.2017 · DOI · Paper page
- Beaver, 1986, A new method for detecting anaerobic threshold by gas exchange, J Appl Physiol, 60, 2020, 10.1152/jappl.1986.60.6.2020 · DOI · Paper page
- Wang, 2017, Tracking changes in the upper boundary of the heavy-intensity exercise domain: end-test power versus respiratory compensation point, Kinesiology, 49, 15, 10.26582/k.49.1.13 · DOI
- Keir, 2016, Influence of muscle metabolic heterogenity in determining the VO2p kinetic response to ramp-incremental exercise, J Appl Physiol, 120, 503, 10.1152/japplphysiol.00804.2015 · DOI · Paper page
- Pringle, 2002, Maximal lactate steady state, critical power and EMG during cycling, Eur J Appl Physiol, 88, 214, 10.1007/s00421-002-0703-4 · DOI · Paper page
- Mattioni Maturana, 2018, Critical power: how different protocols and models affect its determination, J Sci Med Sport, 21, 742, 10.1016/j.jsams.2017.11.015 · DOI · Paper page
- Fontana, 2015, Determination of respiratory point compensation in healthy adults: can non-invasive near-infrared spectroscopy help?, J Sci Med Sport, 18, 590, 10.1016/j.jsams.2014.07.016 · DOI · Paper page
- Craig, 2015, Considerations for identifying the boundaries of sustainable performance, Med Sci Sports Exerc, 47, 1997, 10.1249/mss.0000000000000676 · DOI · Paper page
- Keir, 2015, Response, Med Sci Sports Exerc, 47, 1998, 10.1249/mss.0000000000000677 · DOI
- McKay, 2009, Effect of short-term high-intensity interval training vs continuous training on O2 uptake kinetics, muscle deoxygenation, and exercise performance, J Appl Physiol, 107, 128, 10.1152/japplphysiol.90828.2008 · DOI · Paper page
- Keir, 2015, Exercise intensity thresholds: identifying the boundaries of sustainable performance, Med Sci Sports Exerc, 47, 1932, 10.1249/mss.0000000000000613 · DOI · Paper page
- Prieur, 2005, Effect of endurance training on the V˙O2-work rate relationship in normoxia and hypoxia, Med Sci Sports Exerc, 37, 664, 10.1249/01.mss.0000159140.11938.97 · DOI
- Boone, 2019, The question should be: is HHbBP equivalent to RCP?, Med Sci Sports Exerc, 51, 829, 10.1249/mss.0000000000001850 · DOI
- Keir, 2018, The respiratory compensation point/Deoxy-BP are valid surrogates for critical power/maximum lactate steady state, Med Sci Sports Exerc, 50, 2375, 10.1249/mss.0000000000001698 · DOI · Paper page
- Keir, 2018, Using ramp-incremental V˙O2 responses for constant-intensity exercise selection, Appl Physiol Nutr Metab, 43, 882, 10.1139/apnm-2017-0826 · DOI · Paper page
- Murias, 2013, Sex-related differences in muscle deoxygenation during ramp incremental exercise, Respir Physiol Neurobiol, 189, 530, 10.1016/j.resp.2013.08.011 · DOI · Paper page
- Broxterman, 2015, The relationship between critical speed and the respiratory compensation point: coincidence or equivalence, Eur J Sport Sci, 15, 631, 10.1080/17461391.2014.966764 · DOI · Paper page
- Mattioni Maturana, 2016, Can measures of critical power precisely estimate the maximal metabolic steady-state?, Appl Physiol Nutr Metab, 41, 1197, 10.1139/apnm-2016-0248 · DOI · Paper page
- Iannetta, 2018, Metabolic and performance-related consequences of exercising at and slightly above MLSS, Scand J Med Sci Sports, 28, 2481, 10.1111/sms.13280 · DOI · Paper page
- Bishop, 1998, The critical power function is dependent on the duration of predictive tests chosen, Int J Sports Med, 19, 125, 10.1055/s-2007-971894 · DOI · Paper page
- Iannetta, 2017, Quadriceps muscles O2 extraction and EMG breakpoints during a ramp incremental test, Front Physiol, 8, 686, 10.3389/fphys.2017.00686 · DOI · Paper page
- Scheuermann, 1998, Attenuated respiratory compensation during rapidly incremented ramp exercise, Respir Physiol, 114, 227, 10.1016/s0034-5687(98)00097-8 · DOI
- Boone, 2008, The VO2 response to submaximal ramp cycle exercise: influence of ramp slope and training status, Respir Physiol Neurobiol, 161, 291, 10.1016/j.resp.2008.03.008 · DOI
- Spencer, 2012, Characterizing the profile of muscle deoxygenation during ramp incremental exercise in young men, Eur J Appl Physiol, 112, 3349, 10.1007/s00421-012-2323-y · DOI · Paper page
- Hauser, 2013, Reliability of maximal lactate-steady-state, Int J Sports Med, 34, 196
- Barker, 2006, Human critical power-oxygen uptake relationship at different pedalling frequencies, Exp Physiol, 91, 621, 10.1113/expphysiol.2005.032789 · DOI · Paper page
- Broxterman, 2018, The respiratory compensation point and the deoxygenation break point are not valid surrogates for critical power and maximum lactate steady state, Med Sci Sports Exerc, 50, 2379, 10.1249/mss.0000000000001699 · DOI · Paper page
Cited by
Iannetta, D., de Almeida Azevedo, R., Keir, D. A., & Murias, J. M. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00508.2019 · Cited by 109
Self-citationMuscle Oximetry in Sports Science: An Updated Systematic Review
Perrey, S., Quaresima, V., & Ferrari, M. (2024) · Sports Medicine · doi:10.1007/s40279-023-01987-x · Cited by 100
A “Step–Ramp–Step” Protocol to Identify the Maximal Metabolic Steady State
IANNETTA, D., INGLIS, E. C., POGLIAGHI, S., MURIAS, J. M., & KEIR, D. A. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002343 · Cited by 84
Self-citationYogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
The Respiratory Compensation Point: Mechanisms and Relation to the Maximal Metabolic Steady State
Keir, D. A., Pogliaghi, S., Inglis, E. C., Murias, J. M., & Iannetta, D. (2024) · Sports Medicine · doi:10.1007/s40279-024-02084-3 · Cited by 43
Self-citation
Metadata
- Authors
- Inglis, E. C., Iannetta, D., Keir, D. A., & Murias, J. M.
- Venue
- International Journal of Sports Physiology and Performance
- Publisher
- Human Kinetics
- Published
- 2020-01-01
- Volume
- 15
- Issue
- 1
- Pages
- 119-125
- ISSN
- 1555-0265 (ISSN-L)
- 1555-0273
- OpenAlex
- W2943802763
- Semantic Scholar
- b3d5a15a849db01db95eb1ccb68f80a89559d81b
- Cited by
- 21
- References
- 36
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 1
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Sports Physiology and Performance (publishedVersion)
- PubMed (publishedVersion)
- Institutional Research Information System (Università degli Studi di Brescia) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- respiratory compensation point, maximal lactate steady state, training-induced changes, oxygen consumption, cycling, near-infrared spectroscopy, muscle oxygenation, cardiorespiratory fitness, training season
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.