CoChat

Bend, stretch, and touch: Locating a finger on an actively deformed transparent sensor array

Open access

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

A stretchable, transparent touch pad and proximity sensor made using silicone and gel operates while being bent and stretched.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.1602200

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Working principle and general properties. (A) Mutual capacitive coupling is simulated between two planar electrodes (shown in the inset without a finger). The coupling between electrodes is reduced by the presence of a finger, which acts as an electrode itself. (B) Finger approaching a pair of electrodes that are in the form of a loop and disc. The finger reduces the coupling between the electrodes (CM) by coupling itself with the projected field (CF is increased). (C) Two-dimensional array of loop-disc electrode pattern, with the loops on top. (D) Sensor array sitting above a forearm and a printed number pad. (E) Sensor array on an LCD with a video playing demonstrating transparency. Two edges of the sensor are indicated by the dashed lines. A third edge is just visible, extending perpendicular to the lower line. (F) Sensor array wrapped around a finger demonstrating conformity.
Fig. 1 Working principle and general properties. (A) Mutual capacitive coupling is simulated between two planar electrodes (shown in the inset without a finger). The coupling between electrodes is reduced by the presence of a finger, which acts as an electrode itself. (B) Finger approaching a pair of electrodes that are in the form of a loop and disc. The finger reduces the coupling between the electrodes (CM) by coupling itself with the projected field (CF is increased). (C) Two-dimensional array of loop-disc electrode pattern, with the loops on top. (D) Sensor array sitting above a forearm and a printed number pad. (E) Sensor array on an LCD with a video playing demonstrating transparency. Two edges of the sensor are indicated by the dashed lines. A third edge is just visible, extending perpendicular to the lower line. (F) Sensor array wrapped around a finger demonstrating conformity.CC BY-NC · PubMed Central
Fig. 2 Sensor fabrication and sensitivity. (A) Curing PDMS in a mold. (B) Plasma-bonding three layers forming perpendicular channels on top and bottom of the dielectric. (C) Injecting the monomer mixture inside the channels and polymerizing them to form the ionically conducting electrodes. (D) Map showing the localized change in capacitance due to a touch by a finger. (E) Change in capacitance due to a hovering finger at various distances from the top of the sensor. The change in capacitance upon approach of the finger is negative, as indicated.
Fig. 2 Sensor fabrication and sensitivity. (A) Curing PDMS in a mold. (B) Plasma-bonding three layers forming perpendicular channels on top and bottom of the dielectric. (C) Injecting the monomer mixture inside the channels and polymerizing them to form the ionically conducting electrodes. (D) Map showing the localized change in capacitance due to a touch by a finger. (E) Change in capacitance due to a hovering finger at various distances from the top of the sensor. The change in capacitance upon approach of the finger is negative, as indicated.CC BY-NC · PubMed Central
Fig. 3 Touching while stretching and bending. (A) Plot showing the recorded displacement (7% strain) and capacitance of a single taxel in the sensor while being stretched by a sinusoidally varying displacement using a dynamic mechanical analyzer; the sharp drops in capacitance coincide with touch, while the sinusoidally varying changes are the result of the stretching. (B) Sensor in steady state. (C) Stable capacitance map for steady state. (D) Sensor folded in an anticlockwise direction. (E) Resulting small positive change in capacitance of the taxels along the axis of bend where capacitance increases with positive y axis. (F) Sensor being touched while being bent. (G) Negative change in capacitance map showing the taxel touched having a change in capacitance of 10%, reduced slightly by the change due to the bend where the capacitance decreases with positive y axis. (H) Sensor being bent in the clockwise direction. (I) Positive change in capacitance map showing the axis of bend and a similar response to that in (E).
Fig. 3 Touching while stretching and bending. (A) Plot showing the recorded displacement (7% strain) and capacitance of a single taxel in the sensor while being stretched by a sinusoidally varying displacement using a dynamic mechanical analyzer; the sharp drops in capacitance coincide with touch, while the sinusoidally varying changes are the result of the stretching. (B) Sensor in steady state. (C) Stable capacitance map for steady state. (D) Sensor folded in an anticlockwise direction. (E) Resulting small positive change in capacitance of the taxels along the axis of bend where capacitance increases with positive y axis. (F) Sensor being touched while being bent. (G) Negative change in capacitance map showing the taxel touched having a change in capacitance of 10%, reduced slightly by the change due to the bend where the capacitance decreases with positive y axis. (H) Sensor being bent in the clockwise direction. (I) Positive change in capacitance map showing the axis of bend and a similar response to that in (E).CC BY-NC · PubMed Central
Fig. 4 Swipe, multitouch, and augmented bend detection. (A) Swipe functionality of the sensor showing the negative change in capacitance following a movement across the row from left to right. (B) Detection of one (top), two (middle), and three (bottom) fingers simultaneously, demonstrating multitouch capability. (C) Diagram of the design and results from an augmented bend sensor (compared with the regular sensor with the neutral axis aligned with the dielectric), with the neutral axis aligned with the top electrode layer, which enhances the detection of bend (bottom left) but still enables the simultaneous detection of touch (bottom right).
Fig. 4 Swipe, multitouch, and augmented bend detection. (A) Swipe functionality of the sensor showing the negative change in capacitance following a movement across the row from left to right. (B) Detection of one (top), two (middle), and three (bottom) fingers simultaneously, demonstrating multitouch capability. (C) Diagram of the design and results from an augmented bend sensor (compared with the regular sensor with the neutral axis aligned with the dielectric), with the neutral axis aligned with the top electrode layer, which enhances the detection of bend (bottom left) but still enables the simultaneous detection of touch (bottom right).CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. A. Schmeder A. Freed Support vector machine learning for gesture signal estimation with a piezo-resistive fabric touch surface in Proceedings of International New Interfaces for Musical Expressions (NIME’10) Sydney Australia 15 to 18 June 2010.

Cited by

See all 384

Metadata

Authors
Sarwar, M. S., Dobashi, Y., Preston, C., Wyss, J. K. M., Mirabbasi, S., & Madden, J. D. W.
Affiliations
University of British Columbia (CA)
Corresponding author
Madden, John David Wyndham
Venue
Science Advances
Published
2017-03-03
Volume
3
Issue
3
Pages
e1602200-e1602200
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2606579376
Cited by
370
References
36
Citations by year
2026: 25 · 2025: 27 · 2024: 35 · 2023: 52 · 2022: 49 · 2021: 53 · 2020: 51 · 2019: 40 · 2018: 33 · 2017: 5
FWCI
15.87
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
Funders
Natural Sciences and Engineering Research Council of Canada (ID0ECPBI15664, 486973-15, ID0E3VBI15665, CGSD2-489277-2016, ID0EU2BI15666, 280915)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
stretchable sensors, hydrogel electrodes, polyacrylamide hydrogel, silicone, capacitive sensing, sensor arrays, wearable devices, electronic skin, flexible electronics, electric field coupling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.