CoChat

Metal oxide semiconductor nanomembrane–based soft unnoticeable multifunctional electronics for wearable human-machine interfaces

Open access

The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.

Abstract

Interactive human-machine interfaces are developed using ultrathin, stretchable, multifunctional metal oxide electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.aav9653

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Ultrathin, stretchable, mechanically imperceptible, multifunctional HMI device for human and robotics. (A) Schematic exploded view of an ultrathin multifunctional HMI device. (B) Optical image of the device on a human forearm. Inset is a magnified image. (C) SEM image of the device on a piece of replicated skin. (D) Optical images of the device on a human skin under mechanical deformation: compressed (left) and stretched (right). (E) Schematic exploded view of the temperature sensor array for the robotic hand. (F) Optical image of the temperature sensor array on a robotic hand. Inset is a magnified image. (G) SEM images of the temperature sensor array. (H) Optical images of the temperature sensor array on the robotic hand under mechanical deformation: bent (left) and stretched (right). Photo credit: Kyoseung Sim, University of Houston.
Fig. 1 Ultrathin, stretchable, mechanically imperceptible, multifunctional HMI device for human and robotics. (A) Schematic exploded view of an ultrathin multifunctional HMI device. (B) Optical image of the device on a human forearm. Inset is a magnified image. (C) SEM image of the device on a piece of replicated skin. (D) Optical images of the device on a human skin under mechanical deformation: compressed (left) and stretched (right). (E) Schematic exploded view of the temperature sensor array for the robotic hand. (F) Optical image of the temperature sensor array on a robotic hand. Inset is a magnified image. (G) SEM images of the temperature sensor array. (H) Optical images of the temperature sensor array on the robotic hand under mechanical deformation: bent (left) and stretched (right). Photo credit: Kyoseung Sim, University of Houston.CC BY-NC · PubMed Central
Fig. 2 Characteristics of the ReRAM and FETs. (A) Schematic exploded view of the IZO nanomembrane–based ReRAM. (B) Optical microscopic image of the ReRAM. (C) I-V characteristics of the bipolar switching of the ReRAM. (D) WRER cycle of the ReRAM. (E) Sequential images of the IZO nanomembrane–based ReRAM under strain and corresponding FEA results of IZO. (F) Current at LRS and HRS and ILRS/IHRS under strain. (G) Schematic exploded view of the IZO FET. (H) Optical microscopic image of the FET. (I) Output characteristics of the FET. (J) Transfer characteristics of the FET. (K) Sequential images of the FETs under strain and corresponding FEA results of IZO. (L) Calculated field-effect mobility of the IZO and ION/IOFF of the FET under strain.
Fig. 2 Characteristics of the ReRAM and FETs. (A) Schematic exploded view of the IZO nanomembrane–based ReRAM. (B) Optical microscopic image of the ReRAM. (C) I-V characteristics of the bipolar switching of the ReRAM. (D) WRER cycle of the ReRAM. (E) Sequential images of the IZO nanomembrane–based ReRAM under strain and corresponding FEA results of IZO. (F) Current at LRS and HRS and ILRS/IHRS under strain. (G) Schematic exploded view of the IZO FET. (H) Optical microscopic image of the FET. (I) Output characteristics of the FET. (J) Transfer characteristics of the FET. (K) Sequential images of the FETs under strain and corresponding FEA results of IZO. (L) Calculated field-effect mobility of the IZO and ION/IOFF of the FET under strain.CC BY-NC · PubMed Central
Fig. 3 Characteristics of UV and temperature sensors. (A) Schematic exploded view of the IZO nanomembrane–based UV sensor. (B) Optical microscopic image of the UV sensor. (C) I-V characteristics of the UV sensor. (D) Calibration curve of the IZO UV sensor. (E) Sequential images of the UV sensor under strain and corresponding FEA results of IZO. (F) IUV/Idark for UV light under strain. (G) Schematic exploded view of the IZO temperature sensor. (H) Optical microscopic image of the temperature sensor. (I) Calibration curve of the temperature sensor. (J) Plot of lnR versus 1000/T of the temperature sensor. (K) Sequential images of the IZO temperature sensor under strain and corresponding FEA results of IZO. (L) Relative resistance change of the temperature sensor under strain.
Fig. 3 Characteristics of UV and temperature sensors. (A) Schematic exploded view of the IZO nanomembrane–based UV sensor. (B) Optical microscopic image of the UV sensor. (C) I-V characteristics of the UV sensor. (D) Calibration curve of the IZO UV sensor. (E) Sequential images of the UV sensor under strain and corresponding FEA results of IZO. (F) IUV/Idark for UV light under strain. (G) Schematic exploded view of the IZO temperature sensor. (H) Optical microscopic image of the temperature sensor. (I) Calibration curve of the temperature sensor. (J) Plot of lnR versus 1000/T of the temperature sensor. (K) Sequential images of the IZO temperature sensor under strain and corresponding FEA results of IZO. (L) Relative resistance change of the temperature sensor under strain.CC BY-NC · PubMed Central
Fig. 4 Characteristics of strain sensor. (A) Schematic exploded view of the IZO strain sensor. (B) Optical microscopic image of the strain sensor. (C) Calibration curve of the strain sensor. (D) Relative resistance change of the strain sensor under cyclic stretching and relaxing. (E) Sequential images of the strain sensor under strain and corresponding FEA results of IZO.
Fig. 4 Characteristics of strain sensor. (A) Schematic exploded view of the IZO strain sensor. (B) Optical microscopic image of the strain sensor. (C) Calibration curve of the strain sensor. (D) Relative resistance change of the strain sensor under cyclic stretching and relaxing. (E) Sequential images of the strain sensor under strain and corresponding FEA results of IZO.CC BY-NC · PubMed Central
Fig. 5 Wearable closed-loop HMI. (A) Representative image of human motion to control the robotic hand. (B) Resistance change of strain sensor on the human skin under different human motions. (C) Representative image of human motion mimicking. (D) Resistance change of strain sensor on human motion mimicking. (E) Representative image of the robotic hand, with the temperature sensor touching the human hand. (F) Resistance change of the temperature sensor on the robotic hand while human hand holds the robot. (G) Schematic exploded view of the resistive microheater. (H) IR temperature mapping of the microheater. (I) Dynamic temperature change under different applied voltages. (J) Calibration curve of the microheater. Photo credit: Kyoseung Sim, University of Houston.
Fig. 5 Wearable closed-loop HMI. (A) Representative image of human motion to control the robotic hand. (B) Resistance change of strain sensor on the human skin under different human motions. (C) Representative image of human motion mimicking. (D) Resistance change of strain sensor on human motion mimicking. (E) Representative image of the robotic hand, with the temperature sensor touching the human hand. (F) Resistance change of the temperature sensor on the robotic hand while human hand holds the robot. (G) Schematic exploded view of the resistive microheater. (H) IR temperature mapping of the microheater. (I) Dynamic temperature change under different applied voltages. (J) Calibration curve of the microheater. Photo credit: Kyoseung Sim, University of Houston.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 45 references

Research works printed but not linked: 1

  1. C. S. L. Tsui P. Jia J. Q. Gan H. Hu K. Yuan EMG-based hands-free wheelchair control with EOG attention shift detection in 2007 IEEE International Conference on Robotics and Biomimetics (ROBIO) Sanya China 15 to 18 December 2007 (IEEE 2007) pp. 1266–1271.

Cited by

Items 201–300 of 305

Metadata

Authors
Sim, K., Rao, Z., Zou, Z., Ershad, F., Lei, J., Thukral, A., Chen, J., Huang, Q.-A., Xiao, J., & Yu, C.
Affiliations
  • University of Houston (US)
  • University of Colorado Boulder (US)
  • Southeast University (CN)
Corresponding author
Yu, Cunjiang
Venue
Science Advances
Published
2019-08-02
Volume
5
Issue
8
Pages
eaav9653-eaav9653
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2966018205
Cited by
305
References
45
Citations by year
2026: 19 · 2025: 40 · 2024: 37 · 2023: 41 · 2022: 51 · 2021: 52 · 2020: 54 · 2019: 11
FWCI
14.81
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion, cc-by-nc)
Funders
  • National Science Foundation (ECCS-1509763, CMMI-1554499)
  • American Chemical Society Petroleum Research Fund (56840-DNI7)
  • NSF funded IUCRC BRAIN Center at the University of Houston (N/A)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Thin-Film Transistor Technologies
Keywords
wearable human-machine interfaces, indium zinc oxide, stretchable electronics, resistive random access memory, field-effect transistors, human motion detection, health sensors, microheaters, closed-loop feedback, soft electronics
MeSH terms
Wearable Electronic Devices, Gels, Indium, Polymers, Semiconductors, Zinc Oxide, Nanostructures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.