CoChat

Long-term reliable physical health monitoring by sweat pore–inspired perforated electronic skins

Open access

The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.

Abstract

Artificial auxetic sweat ducts enable electronic skin sensors to perform reliable and noninvasive health monitoring over a week.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.abg8459

Cites

62 of 62 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Perforated e-skins with inorganic physical sensors. (A) Design of auxetic dumbbell through-hole patterns for driving sweat-permeable channels and synergistic physical properties of e-skins. (B) Schematic illustration of perforated e-skins with (I) auxetic dumbbell through-hole patterns. As the hole interspacing is narrower than the average diameter of a sweat pore, the e-skin can form open channels on the pore. Four multiple sensors—(II) Pt resistance thermometer, (III) capacitive-type Au hydration sensor, and ZnO nano–thin-film–based (IV) strain and (V) UV sensor—are also perforated to suppress sweat trapping at the sensing regions. (C) Optical images of the perforated e-skins showing auxetic dumbbell through-hole patterns, Pt thermometer, Au hydration sensor, ZnO strain, and UV sensor. The images were obtained after lamination on the wrist, except for the leftmost image.
Fig. 1 Perforated e-skins with inorganic physical sensors. (A) Design of auxetic dumbbell through-hole patterns for driving sweat-permeable channels and synergistic physical properties of e-skins. (B) Schematic illustration of perforated e-skins with (I) auxetic dumbbell through-hole patterns. As the hole interspacing is narrower than the average diameter of a sweat pore, the e-skin can form open channels on the pore. Four multiple sensors—(II) Pt resistance thermometer, (III) capacitive-type Au hydration sensor, and ZnO nano–thin-film–based (IV) strain and (V) UV sensor—are also perforated to suppress sweat trapping at the sensing regions. (C) Optical images of the perforated e-skins showing auxetic dumbbell through-hole patterns, Pt thermometer, Au hydration sensor, ZnO strain, and UV sensor. The images were obtained after lamination on the wrist, except for the leftmost image.CC BY-NC · PubMed Central
Fig. 2 Sweat-permeable e-skins with reliable physical sensing. (A) Precision design of auxetic dumbbell through-holes to provide open channels on sweat pores. (B) Changes of TEWL of the forearm after e-skin lamination. (C) Stability of the e-skin/forehead interface under profuse sweating (after having a spicy meal). Perforated e-skins form steady conformal contact on the forehead, whereas sweat trapping and interface delamination occurred on conventional e-skin samples. Photo credit: Hanwool Yeon, Massachusetts Institute of Technology. (D) Areal changes of sweat trapped region after sweating. (E) Dehydration monitoring of moisturized forearm. Only the fully perforated e-skin obtained similar dehydration tendencies with the reference skin region measured by commercial skin hydration analyzer (Corneometer CM 825). (F) Skin compatibility test of e-skins through 1-week lamination on the forearm. (G) Tracking of forehead movements using strain sensors. During sweating, the ZnO strain sensor in perforated e-skins reliably monitors the movement, whereas malfunction occurs at the strain sensors in conventional e-skins because of sweat trapping and interface delamination. (H) Changes of skin hydration level and skin temperature after profuse sweating on the forehead.
Fig. 2 Sweat-permeable e-skins with reliable physical sensing. (A) Precision design of auxetic dumbbell through-holes to provide open channels on sweat pores. (B) Changes of TEWL of the forearm after e-skin lamination. (C) Stability of the e-skin/forehead interface under profuse sweating (after having a spicy meal). Perforated e-skins form steady conformal contact on the forehead, whereas sweat trapping and interface delamination occurred on conventional e-skin samples. Photo credit: Hanwool Yeon, Massachusetts Institute of Technology. (D) Areal changes of sweat trapped region after sweating. (E) Dehydration monitoring of moisturized forearm. Only the fully perforated e-skin obtained similar dehydration tendencies with the reference skin region measured by commercial skin hydration analyzer (Corneometer CM 825). (F) Skin compatibility test of e-skins through 1-week lamination on the forearm. (G) Tracking of forehead movements using strain sensors. During sweating, the ZnO strain sensor in perforated e-skins reliably monitors the movement, whereas malfunction occurs at the strain sensors in conventional e-skins because of sweat trapping and interface delamination. (H) Changes of skin hydration level and skin temperature after profuse sweating on the forehead.CC BY-NC · PubMed Central
Fig. 3 Mechanical performance of perforated e-skins. (A) Optical images of perforated e-skins showing conformal contact on the forearm. (B) Work of adhesion of nonperforated, conventional, and perforated e-skins. (C) Strain distribution of three different patterns (circular hole, auxetic kirigami, and auxetic dumbbell) in uniaxial stretching simulation. (D) Cyclic bending fatigue test of e-skins under 0.15 mm−1 bending curvature (3.8% nominal tensile strain) with various perforated patterns (no-pattern, circular hole, auxetic kirigami, and auxetic dumbbell holes). (E) Mechanical durability of e-skins with respect to the bending curvature. (F) Areal mass density of e-skins.
Fig. 3 Mechanical performance of perforated e-skins. (A) Optical images of perforated e-skins showing conformal contact on the forearm. (B) Work of adhesion of nonperforated, conventional, and perforated e-skins. (C) Strain distribution of three different patterns (circular hole, auxetic kirigami, and auxetic dumbbell) in uniaxial stretching simulation. (D) Cyclic bending fatigue test of e-skins under 0.15 mm−1 bending curvature (3.8% nominal tensile strain) with various perforated patterns (no-pattern, circular hole, auxetic kirigami, and auxetic dumbbell holes). (E) Mechanical durability of e-skins with respect to the bending curvature. (F) Areal mass density of e-skins.CC BY-NC · PubMed Central
Fig. 4 Long-term health monitoring by perforated e-skins. (A) Skin regeneration monitoring over a period of 2 weeks. Photographs of the inflamed skin region right after erythema and after 2 weeks, showing that perforated e-skin has a negligible adverse effect to skin regeneration (left images). Scale bars, 5 mm. Hydration level of the inflamed skin as a function of e-skin lamination days (right graph). Skin hydration level was monitored by a hydration sensor in the e-skin and simultaneously compared with a conventional hydration analyzer (Corneometer CM 825). Photo credit: Haneol Lee, Massachusetts Institute of Technology. (B) Daily activity checkup using perforated e-skin with multiple sensors for a week: wrist pulse, skin hydration level, skin temperature, and photoconductance. (C) Comparison of skin information using perforated e-skin before and after exercise at the gym over 30 min (top: wrist pulse, middle: skin hydration level, and bottom: skin temperature).
Fig. 4 Long-term health monitoring by perforated e-skins. (A) Skin regeneration monitoring over a period of 2 weeks. Photographs of the inflamed skin region right after erythema and after 2 weeks, showing that perforated e-skin has a negligible adverse effect to skin regeneration (left images). Scale bars, 5 mm. Hydration level of the inflamed skin as a function of e-skin lamination days (right graph). Skin hydration level was monitored by a hydration sensor in the e-skin and simultaneously compared with a conventional hydration analyzer (Corneometer CM 825). Photo credit: Haneol Lee, Massachusetts Institute of Technology. (B) Daily activity checkup using perforated e-skin with multiple sensors for a week: wrist pulse, skin hydration level, skin temperature, and photoconductance. (C) Comparison of skin information using perforated e-skin before and after exercise at the gym over 30 min (top: wrist pulse, middle: skin hydration level, and bottom: skin temperature).CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 62 references

Cited by

Items 101–192 of 192

Metadata

Authors
Yeon, H., Lee, H., Kim, Y., Lee, D., Lee, Y., Lee, J.-S., Shin, J., Choi, C., Kang, J.-H., Suh, J. M., Kim, H., Kum, H. S., Lee, J., Kim, D., Ko, K., Ma, B. S., Lin, P., Han, S., Kim, S., Bae, S.-H., Kim, T.-S., Park, M.-C., Joo, Y.-C., Kim, E., Han, J., & Kim, J.
Affiliations
  • Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
  • Massachusetts Institute of Technology (US)
  • Seoul National University (KR)
  • Center for Opto-Electronic Materials and Devices, Korea Institute of Science and Technology, Seoul, South Korea.
  • Korea Institute of Science and Technology (KR)
  • Sejong University (KR)
  • Korea Advanced Institute of Science and Technology (KR)
  • Amorepacific (South Korea) (KR)
  • Chung-Ang University Healthcare System (KR)
Corresponding author
  • Han, Jiyeon
  • Kim, Jeehwan
Venue
Science Advances
Published
2021-07-02
Volume
7
Issue
27
ISSN
2375-2548 (ISSN-L)
OpenAlex
W3176312517
Cited by
190
References
62
Citations by year
2026: 30 · 2025: 37 · 2024: 43 · 2023: 36 · 2022: 38 · 2021: 6
FWCI
9.34
Type
journal article
Language
en
Open access
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
  • Seoul National University Open Repository (Seoul National University) (submittedVersion)
Funders
Amorepacific Corporation
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
electronic skin, mechanical reliability, long-term health monitoring, wearable sensors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.