The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Abstract
An ultrasensitive method for detecting protein analytes has been developed. The system relies on magnetic microparticle probes with antibodies that specifically bind a target of interest [prostate-specific antigen (PSA) in this case] and nanoparticle probes that are encoded with DNA that is unique to the protein target of interest and antibodies that can sandwich the target captured by the microparticle probes. Magnetic separation of the complexed probes and target followed by dehybridization of the oligonucleotides on the nanoparticle probe surface allows the determination of the presence of the target protein by identifying the oligonucleotide sequence released from the nanoparticle probe. Because the nanoparticle probe carries with it a large number of oligonucleotides per protein binding event, there is substantial amplification and PSA can be detected at 30 attomolar concentration. Alternatively, a polymerase chain reaction on the oligonucleotide bar codes can boost the sensitivity to 3 attomolar. Comparable clinically accepted conventional assays for detecting the same target have sensitivity limits of ∼3 picomdar, six orders of magnitude less sensitive than what is observed with this method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
A DNA-based method for rationally assembling nanoparticles into macroscopic materials
Mirkin, C. A., Letsinger, R. L., Mucic, R. C., & Storhoff, J. J. (1996) · Nature · doi:10.1038/382607a0 · Cited by 6,683
Self-citationNanoparticles with Raman Spectroscopic Fingerprints for DNA and RNA Detection
Cao, Y. C., Jin, R., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.297.5586.1536 · Cited by 2,971
Self-citationPrinting Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
Bustin, S. (2002) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0290023 · Cited by 2,546
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Self-citationGlobal Analysis of Protein Activities Using Proteome Chips
Zhu, H., Bilgin, M., Bangham, R., Hall, D., Casamayor, A., Bertone, P., Lan, N., Jansen, R., Bidlingmaier, S., Houfek, T., et al. (2001) · Science · doi:10.1126/science.1062191 · Cited by 1,884
Demers, L. M., Mirkin, C. A., Mucic, R. C., Reynolds, R. A., Letsinger, R. L., Elghanian, R., & Viswanadham, G. (2000) · Analytical Chemistry · doi:10.1021/ac0006627 · Cited by 1,109
Self-citationHaab, B. B., Dunham, M. J., & Brown, P. O. (2001) · Genome Biology · doi:10.1186/gb-2001-2-2-research0004 · Cited by 892
Immuno-PCR: Very Sensitive Antigen Detection by Means of Specific Antibody-DNA Conjugates
Sano, T., Smith, C. L., & Cantor, C. R. (1992) · Science · doi:10.1126/science.1439758 · Cited by 861
Schweitzer, B., Wiltshire, S., Lambert, J., O'Malley, S., Kukanskis, K., Zhu, Z., Kingsmore, S. F., Lizardi, P. M., & Ward, D. C. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.170237197 · Cited by 597
Bio-Barcodes Based on Oligonucleotide-Modified Nanoparticles
Nam, J.-M., Park, S.-J., & Mirkin, C. A. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0178766 · Cited by 245
Self-citationSelf-assembly of DNA-streptavidin nanostructures and their use as reagents in immuno-PCR
Niemeyer, C. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.23.4553 · Cited by 211
Ferguson, R. A., Yu, H., Kalyvas, M., Zammit, S., & Diamandis, E. P. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.5.675 · Cited by 169
Hendrickson, E. R., Truby, T. M. H., Joerger, R. D., Majarian, W. R., & Ebersole, R. C. (1995) · Nucleic Acids Research · doi:10.1093/nar/23.3.522 · Cited by 147
Universal immuno-PCR for ultra-sensitive target proteindetection
Zhou, H., Fisher, R. J., & Papas, T. S. (1993) · Nucleic Acids Research · doi:10.1093/nar/21.25.6038 · Cited by 115
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Self-citation
Metadata
- Authors
- Nam, J.-M., Thaxton, C. S., & Mirkin, C. A.
- Venue
- Science
- Published
- 2003-09-26
- Volume
- 301
- Issue
- 5641
- Pages
- 1884-1886
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1971428641
- Cited by
- 2,390
- References
- 16
- FWCI
- 30.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.