Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
Progress has recently been made in implementing magnetic resonance imaging (MRI) techniques that can be used to obtain images in a fraction of a second rather than in minutes. Echo-planar imaging (EPI) uses only one nuclear spin excitation per image and lends itself to a variety of critical medical and scientific applications. Among these are evaluation of cardiac function in real time, mapping of water diffusion and temperature in tissue, mapping of organ blood pool and perfusion, functional imaging of the central nervous system, depiction of blood and cerebrospinal fluid flow dynamics, and movie imaging of the mobile fetus in utero. Through shortened patient examination times, higher patient throughput, and lower cost per MRI examination, EPI may become a powerful tool for early diagnosis of some common and potentially treatable diseases such as ischemic heart disease, stroke, and cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Self-citationTumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Research works printed but not linked: 22
- Belliveau, J. W., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 202 (1991).
- Bourland, J. D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 1157 (1990).
- Budinger, T. F., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 276 (1990).
- EHMAN, L.R., AM J ROENTGENOL 143: 1175 (1985).
- Fischer, H., 75th Annual Meeting of the Radiological Society of North America: 276 (1989).
- HENKELMAN, R.M., REV MAGN RESON MED 2: 1 (1987).
- Higuchi, N., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 638 (1990).
- Kose, K., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 168 (1990).
- KUMAR, A, NMR FOURIER ZEUGMATOGRAPHY, JOURNAL OF MAGNETIC RESONANCE 18: 69 (1975).
- MOONEN, CTW, RADIOLOGY 171: 853 (1989). · DOI · Paper page
- Ordidge, R. J., Eighth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 889 (1989).
- PATRONAS, N, NEURORADIOLOGY 33 Supplement: 267 (1991).
- RADON, J, BER VERH SACHS AK MN 69: 262 (1917).
- Roemer, P. B., Fifth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 1067 (1986).
- ROSEN, B.R., JOURNAL OF GEOLOGICAL EDUCATION 5: 263 (1989).
- Stehling M. K. American Journal of Roentgenology in press.
- Stehling M. K. Radiology in press.
- STEHLING, M.K., ECHO-PLANAR MAGNETIC-RESONANCE IMAGING IN ABNORMAL PREGNANCIES, LANCET 2: 157 (1989).
- STEHLING, M.K., 8TH ANN M SOC MAGN R: 50 (1990).
- Wedeen, V. J., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 164 (1990).
- White, D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 57 (1990).
- Wilke N. Radiology in press.
Cited by
Items 201–300 of 729
Whole-body MRI: a practical guide for imaging patients with malignant bone disease
Winfield, J. M., Blackledge, M., Tunariu, N., Koh, D., & Messiou, C. (2021) · Clinical Radiology · doi:10.1016/j.crad.2021.04.001 · Cited by 30
Lateral modulation of BOLD activation in unstimulated regions of the human visual cortex
Chen, C., Tyler, C. W., Liu, C.-L., & Wang, Y.-H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.09.021 · Cited by 30
Rapid Multiphase Flow Dynamics Mapped by Single‐Shot MRI Velocimetry
Amar, A., Blümich, B., & Casanova, F. (2010) · ChemPhysChem · doi:10.1002/cphc.201000062 · Cited by 30
Huang, J., Ding, W., Lv, J., Yang, J., Dong, H., Ser, J. D., Xia, J., Ren, T., Wong, S. T. C., & Yang, G. (2022) · Applied Intelligence · doi:10.1007/s10489-021-03092-w · Cited by 29
Overcoming limitations in diffusion‐weighted MRI of breast by spatio‐temporal encoding
Solomon, E., Nissan, N., Furman‐Haran, E., Seginer, A., Shapiro‐Feinberg, M., Degani, H., & Frydman, L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25344 · Cited by 29
Diffusion tensor imaging in abdominal organs
Lanzman, R. S., & Wittsack, H. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3434 · Cited by 29
Single‐scan MRI with exceptional resilience to field heterogeneities
Zhang, Z., Seginer, A., & Frydman, L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26145 · Cited by 29
Investigating the impact of autocorrelation on time-varying connectivity
Honari, H., Choe, A. S., Pekar, J. J., & Lindquist, M. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.042 · Cited by 29
Khushu, S., Kumaran, S. S., Tripathi, R. P., Gupta, A., Jain, P., & Jain, V. (2001) · Journal of Biosciences · doi:10.1007/bf02703644 · Cited by 29
Multiple echo diffusion tensor acquisition technique
Sigmund, E. E., & Song, Y. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.015 · Cited by 29
Davis, C. P., McKinnon, G., Debatin, J. F., Duewell, S., & von Schulthess, G. K. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050119 · Cited by 29
A 16-Channel Dipole Antenna Array for Human Head Magnetic Resonance Imaging at 10.5 Tesla
Woo, M. K., DelaBarre, L. J., Waks, M., Radder, J., Choi, U.-S., Lagore, R., Uǧurbil, K., & Adriany, G. (2021) · Sensors · doi:10.3390/s21217250 · Cited by 28
Super-resolved enhancing and edge deghosting (SEED) for spatiotemporally encoded single-shot MRI
Chen, L., Li, J., Zhang, M., Cai, S., Zhang, T., Cai, C., & Chen, Z. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.03.004 · Cited by 28
Schmitt, F. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-397025-1.00006-3 · Cited by 28
Giraud, N., Pitoux, D., Ouvrard, J., & Merlet, D. (2013) · Chemistry - A European Journal · doi:10.1002/chem.201302005 · Cited by 27
Statistical properties of BOLD magnetic resonance activity in the human brain
Chen, C., Tyler, C. W., & Baseler, H. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00358-6 · Cited by 27
Rapid line scan technique for artifact-free images of moving objects
Ailion, D. C., Ganesan, K., Case, T. A., & Christman, R. (1992) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(92)90407-q · Cited by 27
In vivo High Angular Resolution Diffusion-Weighted Imaging of Mouse Brain at 16.4 Tesla
Alomair, O. I., Brereton, I. M., Smith, M. T., Galloway, G. J., & Kurniawan, N. D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0130133 · Cited by 26
Boyce, C. M., Penn, A., Lehnert, M., Pruessmann, K. P., & Müller, C. R. (2018) · Powder Technology · doi:10.1016/j.powtec.2018.11.091 · Cited by 25
High-resolution spiral imaging on a whole-body 7T scanner with minimized image blurring
Qian, Y., Zhao, T., Hue, Y., Ibrahim, T. S., & Boada, F. E. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22215 · Cited by 25
Osteoarthritis and magnetic resonance imaging: potential and problems.
Hutton, C., & Vennart, W. (1995) · Annals of the Rheumatic Diseases · doi:10.1136/ard.54.4.237 · Cited by 25
MRI monitoring of experimental cerebral ischaemia: comparison of two models
Forsting, M., Reith, W., D�rfler, A., Meyding-Lamad�, U., & Sartor, K. J. (1994) · Neuroradiology · doi:10.1007/bf00593255 · Cited by 25
Nataraj, G., Nielsen, J., & Fessler, J. A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2614967 · Cited by 24
Hellemann, E., Teles, R. R., Hallwass, F., Barros, W., Navarro‐Vázquez, A., & Gil, R. R. (2016) · Chemistry - A European Journal · doi:10.1002/chem.201603333 · Cited by 24
T‐Hex: Tilted hexagonal grids for rapid 3D imaging
Engel, M., Kasper, L., Wilm, B. J., Dietrich, B. E., Vionnet, L., Hennel, F., Reber, J., & Pruessmann, K. P. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28600 · Cited by 24
IRM fonctionnelle cérébrale : bases physiologiques, techniques et applications cliniques
Delmaire, C., Krainik, A., Thuc, V. L., Reyns, N., Duffau, H., Capelle, L., & Lehéricy, S. (2007) · Journal de Radiologie · doi:10.1016/s0221-0363(07)89849-0 · Cited by 24
Robust autocalibrated structured low‐rank EPI ghost correction
Lobos, R. A., Hoge, W. S., Javed, A., Liao, C., Setsompop, K., Nayak, K. S., & Haldar, J. P. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28638 · Cited by 23
Monolithically integrated Helmholtz coils by 3-dimensional printing
Li, L., Abedini‐Nassab, R., & Yellen, B. B. (2014) · Applied Physics Letters · doi:10.1063/1.4885441 · Cited by 23
Small animal neuroimaging using magnetic resonance microscopy
Ahrens, E. T., Narasimhan, P. T., Nakada, T., & Jacobs, R. E. (2002) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(02)00003-1 · Cited by 23
The critique of quantum mind: measurement,consciousness, delayed choice, and lost coherence
Zheltikov, A. M. (2017) · Physics-Uspekhi · doi:10.3367/ufne.2017.06.038155 · Cited by 22
Hashimoto, F., Ote, K., Oida, T., Teramoto, A., & Ouchi, Y. (2020) · Applied Sciences · doi:10.3390/app10061902 · Cited by 22
Hagspiel, K. D., Kandarpa, K., & Jolesz, F. A. (1997) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(97)70656-0 · Cited by 22
STRUCTURAL AND FUNCTIONAL NEUROIMAGING FINDINGS IN SUBSTANCE-RELATED DISORDERS
Netrakom, P., Krasuski, J., Miller, N. S., & O’Tuama, L. A. (1999) · Psychiatric Clinics of North America · doi:10.1016/s0193-953x(05)70079-4 · Cited by 22
Silva, A. C., Barbier, E., Lowe, I. J., & Koretsky, A. P. (1998) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1547 · Cited by 22
Rennebaum, H. S., Brummerloh, D. L., Benders, S., & Penn, A. (2023) · Powder Technology · doi:10.1016/j.powtec.2023.119114 · Cited by 21
Susceptibility‐induced distortion correction in hyperpolarized echo planar imaging
Miller, J. J. J. J., Lau, A. Z., & Tyler, D. J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26839 · Cited by 21
Fetal Echoplanar Imaging: Promises and Challenges
Afacan, O., Estroff, J. A., Yang, E., Barnewolt, C. E., Connolly, S. A., Parad, R. B., Mulkern, R. V., Warfield, S. K., & Gholipour, A. (2019) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0000000000000219 · Cited by 21
Papaioannou, G., Mitrogiannis, C., Nianios, G., & Fiedler, G. (2010) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3181cca7bb · Cited by 21
Miyati, T., Banno, T., Fujita, H., Mase, M., Narita, H., Imazawa, M., & Ohba, S. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796286 · Cited by 21
Cheng, K. H., & Hernandez, M. S. (1992) · PubMed · Cited by 21
Magnetic resonance diffusion imaging of ovarian masses: a first experience with 12 cases
Sarty, G. E., Kendall, E. J., Loewy, J., Dhir, A., Olatunbosun, O. A., & Pierson, R. A. (2004) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-003-0027-3 · Cited by 20
Vinding, M. S., Brenner, D., Tse, D. H. Y., Vellmer, S., Vosegaard, T., Suter, D., Stöcker, T., & Maximov, I. I. (2016) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-016-0580-1 · Cited by 20
Improving functional imaging techniques: The dream of a single image for a single mental event
Grabowski, T. J., & Damásio, A. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14302 · Cited by 20
Landro, M. D., Ianniello, J., Yon, M., Wolf, A. A., Quesson, B., Schena, E., & Saccomandi, P. (2020) · Sensors · doi:10.3390/s20226468 · Cited by 19
Asymmetric gradient coil design for use in a short, open bore magnetic resonance imaging scanner
Wang, Y., Liu, F., Li, Y., Tang, F., & Crozier, . (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.06.015 · Cited by 19
Li, J., Wang, Y., He, K., Peng, C., Wu, P., Li, C., & Lai, X. (2018) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2018/5712857 · Cited by 19
Contemporary approaches to high-field magnetic resonance imaging with large field inhomogeneity
Mullen, M., & Garwood, M. (2020) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2020.07.003 · Cited by 19
Braus, D. F., Tost, H., Hirsch, J. G., & Gass, A. (2001) · Der Nervenarzt · doi:10.1007/s001150050769 · Cited by 19
Ictal imaging using functional magnetic resonance
Connelly, A. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02037-t · Cited by 19
Superconducting Quantum Magnetometers for Brain Investigations
Bonavolontà, C., Vettoliere, A., Sorrentino, P., & Granata, C. (2025) · Sensors · doi:10.3390/s25154625 · Cited by 18
Ultrafast in vivo diffusion imaging of stroke at 21.1 T by spatiotemporal encoding
Leftin, A., Rosenberg, J. T., Solomon, E., Bejarano, F. C., Grant, S. C., & Frydman, L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25271 · Cited by 18
Neuroimaging perspectives on fetal motor behavior
Hayat, T. T. A., & Rutherford, M. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.06.001 · Cited by 18
Wake volume of injected bubbles in fluidized beds: A magnetic resonance imaging velocimetry study
Boyce, C. M., Penn, A., Lehnert, M., Pruessmann, K. P., & Müller, C. R. (2019) · Powder Technology · doi:10.1016/j.powtec.2019.02.021 · Cited by 18
Xi, K., Kovar, T. M., Fullmer, W. D., Penn, A., Musser, J. M. H., & Boyce, C. M. (2021) · Powder Technology · doi:10.1016/j.powtec.2021.04.075 · Cited by 18
Improved Perfusion and Tracer Kinetic Imaging Using Parallel Imaging
Stollberger, R., & Fazekas, F. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000139298.74366.6b · Cited by 18
Functional magnetic resonance imaging: Clinical applications and potential
Matthews, P. M., Clare, S., & Adcock, J. (1999) · Journal of Inherited Metabolic Disease · doi:10.1023/a:1005535102667 · Cited by 18
Imaging the head: functional imaging.
Sawle, G. V. (1995) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.58.2.132 · Cited by 18
Rapid three‐dimensional velocimetry by nuclear magnetic resonance imaging
Derbyshire, J. A., Gibbs, S. J., Carpenter, T. A., & Hall, L. D. (1994) · AIChE Journal · doi:10.1002/aic.690400811 · Cited by 18
Multi‐shot acquisitions for stimulus‐evoked spinal cord BOLD fMRI
Barry, R. L., Conrad, B. N., Maki, S., Watchmaker, J. M., McKeithan, L. J., Box, B. A., Weinberg, Q. R., Smith, S. A., & Gore, J. C. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28570 · Cited by 17
A silent gradient axis for soundless spatial encoding to enable fast and quiet brain imaging
Versteeg, E., Klomp, D. W. J., & Siero, J. C. W. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29010 · Cited by 17
Neuroanatomical Micromagnetic Resonance Imaging
Narasimhan, P. T., & Jacobs, R. E. (2002) · Elsevier eBooks · doi:10.1016/b978-012693019-1/50018-6 · Cited by 17
Rofsky, N. M., Pizzarello, D. J., Duhaney, M., Falick, A. K., Prendergast, N. C., & Weinreb, J. C. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80405-2 · Cited by 17
Mori, Y., Miyata, J., Isobe, M., Son, S., Yoshihara, Y., Aso, T., Kouchiyama, T., Murai, T., & Takahashi, H. (2018) · Psychiatry and Clinical Neurosciences · doi:10.1111/pcn.12677 · Cited by 17
Khushu, S., Kumaran, S. S., Sekhri, T., Tripathi, R. P., Jain, P., & Jain, V. (2006) · Journal of Biosciences · doi:10.1007/bf02708405 · Cited by 17
Echo-Planar Imaging Pulse Sequences
Wielopolski, P. A., Schmitt, F., & Stehling, M. K. (1998) · Springer eBooks · doi:10.1007/978-3-642-80443-4_4 · Cited by 17
Self-citationA CUDA-based reverse gridding algorithm for MR reconstruction
Yang, J., Feng, C., & Zhao, D. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.038 · Cited by 16
“Although EPI can finish sampling in less than 1 s [14,15] and use fast Fourier transform (FFT) to reconstruct images directly [16–18], it requires a professional gradient system.”
MethodCross-encoded magnetic resonance imaging in inhomogeneous fields
Paquin, R., Pelupessy, P., & Bodenhausen, G. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.09.008 · Cited by 16
Magnetic resonance signal moment determination using the Earth’s magnetic field
Fridjonsson, E. O., Creber, S. A., Vrouwenvelder, J. S., & Johns, M. L. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.01.013 · Cited by 16
Changes in functional magnetic resonance imaging with Yogic meditation: A pilot study
Mishra, S., Khosa, S., Singh, S., Moheb, N., & Trikamji, B. (2017) · AYU (An International Quarterly Journal of Research in Ayurveda) · doi:10.4103/ayu.ayu_34_17 · Cited by 16
Frydman, L., & Peng, J. (1994) · Chemical Physics Letters · doi:10.1016/0009-2614(94)87077-2 · Cited by 16
Assessment of myocardial perfusion by magnetic resonance imaging
Crnac, J., Schmidt, M. C., THEISSEN, P., & Sechtem, U. P. (1997) · Herz · doi:10.1007/bf03044567 · Cited by 16
Skeletal Development on Fetal Magnetic Resonance Imaging
Nemec, S. F., Nemec, U., Brugger, P. C., Wadhawan, I., & Prayer, D. (2011) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3182676153 · Cited by 15
Investigating the Group-Level Impact of Advanced Dual-Echo fMRI Combinations
Kettinger, Á. O., Hill, C., Vidnyánszky, Z., Windischberger, C., & Nagy, Z. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00571 · Cited by 15
Bao, Q., Liberman, G., Solomon, E., & Frydman, L. (2019) · NMR in Biomedicine · doi:10.1002/nbm.4208 · Cited by 15
Cheng, K. H. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90476-t · Cited by 15
Echo-Planar Magnetic Resonance Imaging of Human Brain Activation
Bandettini, P. A., & Wong, E. C. (1998) · Springer eBooks · doi:10.1007/978-3-642-80443-4_15 · Cited by 15
Solomon, E., Nissan, N., Schmidt, R., Furman‐Haran, E., Ben-Aharon, U., & Frydman, L. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25757 · Cited by 14
Kang, A., & Kliot, M. (2013) · Springer eBooks · doi:10.1007/978-1-4614-6552-2_7 · Cited by 14
Dynamic T2 mapping by multi‐spin‐echo spatiotemporal encoding
Bao, Q., Ma, L., Liberman, G., Solomon, E., Martinho, R. P., & Frydman, L. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28158 · Cited by 14
Murata, Y., KUBOTA, K., Hamada, N., Miyatake, K., Tadokoro, M., Nakatani, K., Ue, H., TSUZUKI, K., Nishioka, A., Iguchi, M., et al. (2010) · Oncology Letters · doi:10.3892/ol_00000052 · Cited by 14
Hoinkiss, D. C., & Porter, D. A. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26951 · Cited by 14
Spectral Analysis of fMRI Signal and Noise
Chen, C., & Tyler, C. W. (2008) · Springer eBooks · doi:10.1007/978-4-431-73242-6_4 · Cited by 14
Okuda, S., Tanimoto, A., Satoh, T., Hashimoto, J., Shinmoto, H., Higuchi, N., Nozaki, A., & Kuribayashi, S. (2005) · PubMed · Cited by 14
Induced magnetic field gradients and forces in the human head in MRI
Tomasi, D. G., & Wang, R. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21143 · Cited by 14
3D Echo Planar Imaging: Application to the Human Head
Abduljalil, A., Aletras, A. H., & Robitaille, P.-M. L. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340203 · Cited by 14
Berman, J. S. (1995) · British Journal of Anaesthesia · doi:10.1093/bja/75.2.209 · Cited by 14
Perfusion Magnetic Resonance Imaging Quantification in the Brain
Calamante, F. (2012) · Neuromethods · doi:10.1007/978-1-61779-897-9_13 · Cited by 13
Konar, A. S., Fung, M., Paudyal, R., Oh, J. H., Mazaheri, Y., Hatzoglou, V., & Shukla‐Dave, A. (2020) · Tomography · doi:10.18383/j.tom.2020.00014 · Cited by 13
Role of a modified ultrafast MRI brain protocol in clinical paediatric neuroimaging
Ahamed, S. H., Lee, K. J., & Tang, P. H. (2020) · Clinical Radiology · doi:10.1016/j.crad.2020.07.009 · Cited by 13
Sigmund, E. E., & Gutman, D. A. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.02.016 · Cited by 13
Diffusion‐ and Perfusion‐Weighted MR Imaging in Acute Stroke: Principles, Methods, and Applications
Heiland, S. (2003) · Imaging Decisions MRI · doi:10.1111/j.1433-3317.2003.mri070402.x · Cited by 13
Surgical anatomy and functional connectivity of the limbic system
Lövblad, K., & Schaller, K. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.5.focus09103 · Cited by 13
Principles of Multi-slice Cardiac CT Imaging
Ohnesorge, B. M., & Flohr, T. G. (2006) · Springer eBooks · doi:10.1007/978-3-540-49546-8_4 · Cited by 13
Ultra High Field Magnetic Resonance Imaging: A Historical Perspective
Robitaille, P.-M. L. (2007) · Springer eBooks · doi:10.1007/978-0-387-49648-1_1 · Cited by 13
Partitioning two components of BOLD activation suppression in flanker effects
Chen, C. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00149 · Cited by 13
Mapping human brain activity in vivo.
Mazziotta, J. C. (1994) · PubMed Central · Cited by 13
What roles are there for magnetic resonance imaging in process tomography?
Gibbs, S. J., & Hall, L. D. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/5/015 · Cited by 13
Acoustic radiation force imaging using a single-shot spiral readout
Ilovitsh, A., Fite, B. Z., Ilovitsh, T., & Ferrara, K. W. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab1e21 · Cited by 12
SLIMM: Slice localization integrated MRI monitoring
Sui, Y., Afacan, O., Gholipour, A., & Warfield, S. K. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117280 · Cited by 12
From Photography to fMRI: Epistemic Functions of Images in Medical Research on Hysteria
Muhr, P. (2022) · transcript Verlag eBooks · doi:10.14361/9783839461761 · Cited by 13
Metadata
- Authors
- Stehling, M. K., Turner, R., & Mansfield, P.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Venue
- Science
- Published
- 1991-10-04
- Volume
- 254
- Issue
- 5028
- Pages
- 43-50
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1991844483
- Cited by
- 623
- References
- 93
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 11 · 2023: 18 · 2022: 21 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 19 · 2017: 23 · 2016: 23 · 2015: 21 · 2014: 18 · 2013: 18 · 2012: 8
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Digital Library (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- echo planar imaging, rapid MRI, cardiac function imaging, temperature mapping, blood pool imaging, perfusion imaging, functional MRI, cerebrospinal fluid flow, fetal MRI, ischemic heart disease, stroke, cancer diagnosis
- MeSH terms
- Diffusion, Humans, Magnetic Resonance Imaging, Motion, Regional Blood Flow, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.